Skip to main content
QUICK REVIEW

[Paper Review] Biocompatibility of Pristine Graphene Monolayers, Nanosheets and Thin Films

Jennifer Conroy, Navin Kumar Verma|arXiv (Cornell University)|Jun 10, 2014
Graphene and Nanomaterials ApplicationsEngineering2 references11 citations
TL;DR

This study evaluates the biocompatibility of pristine graphene monolayers, nanosheets, and thin films using human lung epithelial A549 cells. Employing multimodal assays, it demonstrates minimal cytotoxicity, no significant morphological changes, and low reactive oxygen species production, establishing graphene as a promising biocompatible material for biomedical and electronic applications despite higher toxicity in carbon black controls.

ABSTRACT

There is an increasing interest to develop nanoscale biocompatible graphene structures due to their desirable physicochemical properties, unlimited application opportunities and scalable production. Here we report the preparation, characterization and biocompatibility assessment of novel graphene flakes and their enabled thin films suitable for a wide range of biomedical and electronic applications. Graphene flakes were synthesized by a chemical vapour deposition method or a liquid-phase exfoliation procedure and then thin films were prepared by transferring graphene onto glass coverslips. Raman spectroscopy and transmission electron microscopy confirmed a predominantly monolayer and a high crystalline quality formation of graphene. The biocompatibility assessment of graphene thin films and graphene flakes was performed using cultured human lung epithelial cell line A549 employing a multimodal approach incorporating automated imaging, high content screening, real-time impedance sensing in combination with biochemical assays. No detectable changes in the cellular morphology or attachment of A549 cells growing on graphene thin films or cells exposed to graphene flakes (0.1 to 5 ug/mL) for 4 to 72 h was observed. Graphene treatments caused a very low level of increase in cellular production of reactive oxygen species in A549 cells, but no detectable damage to the nuclei such as changes in morphology, condensation or fragmentation was observed. In contrast, carbon black proved to be significantly more toxic than the graphene. These data open up a promising view of using graphene enabled composites for a diverse scope of safer applications.

Motivation & Objective

  • To evaluate the biocompatibility of pristine graphene in various forms—monolayers, nanosheets, and thin films—for potential biomedical and electronic applications.
  • To compare the cytotoxic effects of graphene with those of carbon black, a known toxic carbonaceous material.
  • To assess cellular responses using a multimodal approach combining imaging, impedance sensing, and biochemical assays.
  • To determine whether graphene exposure induces oxidative stress or nuclear damage in human lung epithelial cells.

Proposed method

  • Synthesized graphene flakes via chemical vapor deposition and liquid-phase exfoliation methods.
  • Transferred graphene onto glass coverslips to fabricate thin films for cell culture studies.
  • Characterized graphene using Raman spectroscopy and transmission electron microscopy to confirm monolayer and high crystalline quality.
  • Performed biocompatibility assessment using A549 human lung epithelial cells exposed to graphene flakes (0.1–5 µg/mL) for 4–72 hours.
  • Employed automated imaging, high-content screening, real-time impedance sensing, and biochemical assays to evaluate cell morphology, viability, and oxidative stress.
  • Used carbon black as a positive control to compare toxicity levels.

Experimental results

Research questions

  • RQ1Does pristine graphene in monolayer, nanosheet, or thin film form induce cytotoxic effects in human lung epithelial A549 cells?
  • RQ2How does graphene exposure affect cellular morphology, attachment, and viability over time?
  • RQ3What is the level of reactive oxygen species production in A549 cells following graphene exposure?
  • RQ4Does graphene cause detectable nuclear damage, such as condensation or fragmentation, in A549 cells?
  • RQ5How does the toxicity of graphene compare to that of carbon black in the same cellular model?

Key findings

  • No detectable changes in cellular morphology or attachment were observed in A549 cells cultured on graphene thin films or exposed to graphene flakes (0.1–5 µg/mL) over 4–72 hours.
  • Graphene exposure induced only a very low level of increase in reactive oxygen species production in A549 cells, indicating minimal oxidative stress.
  • No detectable nuclear damage, including changes in morphology, condensation, or fragmentation, was observed in A549 cells after graphene exposure.
  • Carbon black exhibited significantly higher toxicity than graphene, highlighting graphene's superior biocompatibility in this model.
  • Raman spectroscopy and transmission electron microscopy confirmed the formation of predominantly monolayer, high-crystalline graphene structures.
  • The multimodal assessment approach successfully demonstrated the safety of graphene across multiple biological endpoints.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.