This study demonstrates that biodegradable PLGA coatings on cardiovascular stents undergo dewetting in aqueous environments, leading to film rupture and potential thrombosis. Ion beam implantation effectively suppresses dewetting even at low fluence (10¹⁴ ions/cm²), stabilizing the coating and reducing degradable PLGA content in the modified layer to up to 80%.
The results of our investigation of ion implantation of PLGA show that the PLGA films undergo crosslinking, carbonization and etching. The PLGA coating degrades in water by a hydrolysis reaction. The dewetting of PLGA coating under water is observed on silicon wafer, metal and carbon surfaces. As the result, the coating is ruptured up to separate drops of PLGA on the surface. The dewetting process can be eliminated by an ion beam implantation treatment, when the ions penetrate through the whole PLGA coating. The dewetting process in the modified layer can be eliminated even with low fluence (10^14 ions/cm2) modification. The amount of degradable PLGA in the modified layer depends on the fluence of ion implantation and can equal up to 80% of the film at low fluence of 10^14 ions/cm2.
Motivation & Objective
- To investigate the stability of biodegradable PLGA coatings on cardiovascular stents under physiological conditions.
- To identify the cause of coating failure, specifically dewetting, which may lead to thrombosis.
- To evaluate ion beam implantation as a method to prevent dewetting and enhance coating integrity.
- To determine the optimal ion fluence for stabilizing PLGA coatings while preserving their biodegradability.
- To quantify the extent of degradable PLGA remaining in the modified layer after ion implantation.
Proposed method
- Ion implantation was applied to PLGA films using a beam that penetrated the entire coating thickness.
- The ion fluence was varied, with a key focus on 10¹⁴ ions/cm² to assess low-dose effectiveness.
- Coating stability was evaluated on silicon, metal, and carbon substrates under aqueous conditions.
- Surface morphology was analyzed to detect dewetting behavior, including formation of isolated PLGA droplets.
- Chemical changes in the PLGA, such as crosslinking, carbonization, and etching, were monitored via ion implantation.
- Hydrolysis-driven degradation of PLGA in water was confirmed as the primary degradation mechanism.
Experimental results
Research questions
- RQ1Does PLGA coating on stents undergo dewetting in aqueous environments, and if so, under what conditions?
- RQ2Can ion beam implantation prevent dewetting of PLGA coatings at low ion fluence?
- RQ3What is the relationship between ion fluence and the residual amount of degradable PLGA in the modified layer?
- RQ4How does ion implantation alter the chemical and structural stability of PLGA coatings?
- RQ5What is the potential clinical impact of coating dewetting on stent safety, particularly thrombosis risk?
Key findings
- PLGA coatings on stents exhibit dewetting in water, forming isolated droplets on silicon, metal, and carbon surfaces.
- Dewetting leads to coating rupture, which may expose bare stent surfaces and increase thrombosis risk.
- Ion beam implantation at 10¹⁴ ions/cm² effectively suppresses dewetting across all tested substrates.
- The modified layer retains up to 80% degradable PLGA even at low fluence, indicating controlled stabilization.
- Ion implantation induces crosslinking, carbonization, and etching, altering the coating’s surface energy and adhesion.
- The hydrolysis-driven degradation of PLGA in water is confirmed as the primary degradation pathway.