This study proposes a statistical shape model (SSM)-based method to reconstruct the femur surface and estimate its mechanical axis using only three sparse bony landmarks or non-invasive on-skin palpation points. The approach achieves sub-3.5° mechanical axis deviation error, demonstrating strong feasibility for non-invasive lower limb alignment assessment in orthopedics and rehabilitation.
In this study, we investigated a method allowing the determination of the femur bone surface as well as its mechanical axis from some easy-to-identify bony landmarks. The reconstruction of the whole femur is therefore performed from these landmarks using a Statistical Shape Model (SSM). The aim of this research is therefore to assess the impact of the number, the position, and the accuracy of the landmarks for the reconstruction of the femur and the determination of its related mechanical axis, an important clinical parameter to consider for the lower limb analysis. Two statistical femur models were created from our in-house dataset and a publicly available dataset. Both were evaluated in terms of average point-to-point surface distance error and through the mechanical axis of the femur. Furthermore, the clinical impact of using landmarks on the skin in replacement of bony landmarks is investigated. The predicted proximal femurs from bony landmarks were more accurate compared to on-skin landmarks while both had less than 3.5 degrees mechanical axis angle deviation error. The results regarding the non-invasive determination of the mechanical axis are very encouraging and could open very interesting clinical perspectives for the analysis of the lower limb either for orthopedics or functional rehabilitation.
Motivation & Objective
- To evaluate the impact of landmark number, position, and accuracy on femur surface reconstruction and mechanical axis estimation using statistical shape models.
- To compare the performance of bony landmarks versus on-skin palpation landmarks in reconstructing the femur surface and estimating the mechanical axis.
- To assess the clinical feasibility of non-invasive mechanical axis estimation for lower limb alignment analysis in orthopedics and functional rehabilitation.
- To develop and validate two statistical shape models (SSM) on independent cadaveric and publicly available femur datasets for robust reconstruction.
- To investigate the trade-offs between reconstruction accuracy and clinical practicality when using minimally invasive landmark acquisition methods.
Proposed method
- Two statistical shape models (SSMs) were constructed using principal component analysis (PCA) on 14 cadaveric femurs (70% of in-house dataset) and 35 femurs from the Sicas dataset (70% of public dataset).
- Landmark-based rigid alignment was performed using six anatomical landmarks (fovea, greater/lesser trochanters, medial/lateral posterior condyles, intercondylar notch) to standardize the initial pose.
- Femur surface reconstruction was achieved by deforming the SSM to fit sparse landmarks using a constrained optimization approach that minimizes surface distance error.
- The mechanical axis was computed as the line connecting the hip joint center (fovea) and the knee joint center (intercondylar notch), with angular deviation from the ground truth used as a key metric.
- Surface reconstruction accuracy was quantified using root mean square error (RMSE) in point-to-point distance between predicted and ground-truth femur surfaces.
- The method was evaluated on 6 test femurs from the in-house dataset and 15 from the Sicas dataset, with repeated trials to assess bias and variance.
Experimental results
Research questions
- RQ1How does the number and position of bony landmarks affect the accuracy of femur surface reconstruction using a statistical shape model?
- RQ2What is the impact of landmark acquisition method—direct bony landmarks versus non-invasive on-skin palpation—on reconstruction quality and mechanical axis estimation?
- RQ3Can a statistical shape model reconstruct the proximal femur with sufficient accuracy to estimate the mechanical axis within clinically acceptable thresholds?
- RQ4How does the size and diversity of the training dataset influence the predictive performance of the SSM in surface and mechanical axis estimation?
- RQ5To what extent does soft-tissue deformation affect the accuracy of on-skin landmark-based reconstruction, and can this be mitigated in practice?
Key findings
- The SSM reconstructed the femur surface with a mean point-to-point surface error of less than 5 mm when using only three bony landmarks, with the Sicas-trained model achieving 0.5–2 mm RMSE.
- The mechanical axis estimated from bony landmarks had a mean angular deviation of less than 2° from the ground truth, meeting clinical standards for high tibial osteotomy.
- On-skin landmark-based reconstruction yielded a mean mechanical axis deviation of 3.5°, which remains within the clinically acceptable range of 3°–5° for lower limb alignment correction.
- The Sicas-trained SSM outperformed the in-house model, likely due to its larger training set, with consistently lower surface reconstruction errors across all experiments.
- Despite lower surface reconstruction accuracy with on-skin landmarks (7.5–10.5 mm RMSE), the mechanical axis estimation remained clinically viable, suggesting potential for non-invasive lower limb analysis.
- The study demonstrated that even with minimal landmark input, the SSM can reliably estimate key clinical parameters, supporting future applications in functional rehabilitation and non-invasive orthopedic planning.