[Paper Review] Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC
This paper presents a comprehensive calibration and performance evaluation of the LHCb calorimeters during LHC Runs 1 and 2, detailing energy scale calibration, response monitoring, and ageing corrections for the SPD, PS, ECAL, and HCAL. It demonstrates that the calorimeters maintained high performance across increasing beam energies, enabling precise reconstruction of photons, π⁰ mesons, and electrons, with key results including a precise measurement of the Bs⁰ → J/ψ η′/η branching fraction ratio of 0.90 ± 0.09 (stat) ± 0.06 (syst).
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are detailed. A few results from collisions recorded at $\sqrt {s}$ = 7, 8 and 13 TeV are shown.
Motivation & Objective
- To establish and refine calibration procedures for the LHCb calorimeter sub-detectors (SPD, PS, ECAL, HCAL) across Run 1 and Run 2.
- To address the challenges introduced by increased beam energy in Run 2, particularly in energy scale stability and detector response.
- To ensure high-precision reconstruction of neutral particles (γ, π⁰) and electrons for physics analyses using calorimeter data.
- To maintain consistent performance and calibration accuracy despite detector ageing and increased pile-up in Run 2.
- To support the L0 trigger and High-Level Trigger by providing calibrated energy and timing information for real-time event selection.
Proposed method
- Calibration of the SPD and PS using cosmic ray data and MIP (minimum ionizing particle) samples to determine baseline response and efficiency.
- Energy scale calibration of ECAL using radioactive sources (e.g., ⁶⁰Co) and in-situ calibration with known particle decays (e.g., J/ψ → μ⁺μ⁻) and pile-up corrections.
- HCAL calibration via ¹³⁷Cs source measurements and PMT gain monitoring to maintain energy resolution and linearity.
- Application of ageing corrections to ECAL and HCAL using long-term monitoring of light yield and gain variations.
- Use of offline calibration techniques with high-statistics samples from B-meson decays (e.g., Bs⁰ → J/ψ η, η′) to validate and refine energy scale and resolution.
- Integration of calorimeter data into the HLT (High-Level Trigger) in Run 2 to enable offline-quality PID variables during real-time selection.
Experimental results
Research questions
- RQ1How were the energy scales of the LHCb calorimeters calibrated and maintained across Run 1 and Run 2?
- RQ2What changes in calibration procedures were required due to the increase in beam energy from √s = 7–8 TeV (Run 1) to 13 TeV (Run 2)?
- RQ3How did detector ageing and pile-up affect the performance of the ECAL and HCAL, and how were these effects corrected?
- RQ4What is the performance of the calorimeters in reconstructing photons, π⁰ mesons, and electrons, particularly in merged and converted photon configurations?
- RQ5How did the inclusion of calorimeter information in the HLT improve the efficiency and purity of trigger-level selections in Run 2?
Key findings
- The LHCb calorimeters maintained stable performance across Run 1 and Run 2, with successful calibration and ageing corrections ensuring consistent energy resolution and response.
- The ECAL energy resolution was measured to be approximately 1.5% for 1 GeV photons, with corrections applied for non-linearity and pile-up effects.
- The ratio of branching fractions for Bs⁰ → J/ψ η′ and Bs⁰ → J/ψ η decays was measured as 0.90 ± 0.09 (stat) ± 0.06 (syst), consistent with previous Belle results but with improved precision.
- The SPD and PS were successfully calibrated using cosmic rays and MIP samples, with dynamic range and resolution maintained across all regions.
- HCAL calibration using ¹³⁷Cs sources and PMT gain monitoring ensured stable response and energy resolution, even after prolonged operation.
- Incorporating calorimeter and RICH information into the HLT in Run 2 enabled higher-purity calibration samples and improved trigger efficiency for rare decays involving photons and π⁰ mesons.