TL;DR

This study evaluates domain shift in chest radiograph classification by training state-of-the-art deep learning models on four major datasets and testing them across domains. It finds that models trained on ChestX-ray14 and PadChest suffer significant performance drops when tested on other datasets, while models trained on CheXpert and MIMIC-CXR generalize better, highlighting the critical impact of data distribution differences on model reliability in medical imaging.

ABSTRACT

While deep learning models become more widespread, their ability to handle unseen data and generalize for any scenario is yet to be challenged. In medical imaging, there is a high heterogeneity of distributions among images based on the equipment that generates them and their parametrization. This heterogeneity triggers a common issue in machine learning called domain shift, which represents the difference between the training data distribution and the distribution of where a model is employed. A high domain shift tends to implicate in a poor generalization performance from the models. In this work, we evaluate the extent of domain shift on four of the largest datasets of chest radiographs. We show how training and testing with different datasets (e.g., training in ChestX-ray14 and testing in CheXpert) drastically affects model performance, posing a big question over the reliability of deep learning models trained on public datasets. We also show that models trained on CheXpert and MIMIC-CXR generalize better to other datasets.

Motivation & Objective

  • To assess the generalization performance of deep learning models across different chest radiograph datasets due to domain shift.
  • To investigate whether models trained on public datasets can reliably perform on unseen data from different hospitals or imaging centers.
  • To identify which datasets produce more robust models by comparing cross-dataset performance.
  • To evaluate the role of label quality and data distribution heterogeneity in model generalization failure.
  • To provide guidance for researchers on selecting representative datasets for training robust medical imaging models.

Proposed method

  • Trained a state-of-the-art convolutional neural network for multi-label classification on each of four large chest X-ray datasets: ChestX-ray14, CheXpert, MIMIC-CXR, and PadChest.
  • Evaluated each model’s performance on the test sets of the other three datasets to simulate real-world deployment in unseen domains.
  • Used area under the curve (AUC) as the primary metric to quantify model performance across all radiological findings.
  • Compared performance drops across models to identify which source datasets yield more generalizable models.
  • Analyzed label consistency and data distribution differences as potential causes of domain shift.
  • Visualized AUC variations across findings using line plots to illustrate performance stability across domains.

Experimental results

Research questions

  • RQ1How does domain shift affect the performance of deep learning models trained on one chest X-ray dataset when tested on another?
  • RQ2Which of the four major chest X-ray datasets—ChestX-ray14, CheXpert, MIMIC-CXR, and PadChest—produces models with the best generalization across different domains?
  • RQ3To what extent do label quality and data acquisition protocols contribute to domain shift in medical imaging models?
  • RQ4Can models trained on one dataset maintain high performance when deployed in a different clinical setting with different imaging protocols?
  • RQ5What are the implications of these findings for the external validation and real-world deployment of deep learning models in radiology?

Key findings

  • Models trained on ChestX-ray14 showed a mean AUC drop of 0.12 when tested on CheXpert, 0.08 on MIMIC-CXR, and 0.04 on PadChest, indicating severe domain shift.
  • Models trained on CheXpert and MIMIC-CXR preserved over 90% of their baseline mean AUC when tested on other datasets, showing superior generalization.
  • The model trained on PadChest had a 0.10 average AUC drop when tested on other datasets, likely due to smaller training sample sizes per finding.
  • In all four test sets, the highest AUC for each radiological finding was most frequently achieved when training and testing on the same dataset, indicating strong domain-specific bias.
  • CheXpert and MIMIC-CXR datasets demonstrated more consistent and robust performance across domains, suggesting better representativeness of real-world imaging variability.
  • The study found that label reliability issues in ChestX-ray14 may contribute to poor generalization, as visual inspection studies suggest label accuracies are 10–30% lower than reported.