[Paper Review] CBCT-Based Synthetic CT Image Generation Using Conditional Denoising Diffusion Probabilistic Model
This paper proposes a conditional denoising diffusion probabilistic model (DDPM) that translates low-quality cone-beam CT (CBCT) images into synthetic CT (sCT) images with accurate Hounsfield units (HU) and reduced artifacts. Using a time-embedded U-Net with residual and attention blocks, the model is trained on paired deformed planning CT (dpCT) and CBCT scans, achieving state-of-the-art performance in HU accuracy and image quality for online adaptive radiotherapy applications.
Background: Daily or weekly cone-beam computed tomography (CBCT) scans are commonly used for accurate patient positioning during the image-guided radiotherapy (IGRT) process, making it an ideal option for adaptive radiotherapy (ART) replanning. However, the presence of severe artifacts and inaccurate Hounsfield unit (HU) values prevent its use for quantitative applications such as organ segmentation and dose calculation. To enable the clinical practice of online ART, it is crucial to obtain CBCT scans with a quality comparable to that of a CT scan. Purpose: This work aims to develop a conditional diffusion model to perform image translation from the CBCT to the CT domain for the image quality improvement of CBCT. Methods: The proposed method is a conditional denoising diffusion probabilistic model (DDPM) that utilizes a time-embedded U-net architecture with residual and attention blocks to gradually transform standard Gaussian noise to the target CT distribution conditioned on the CBCT. The model was trained on deformed planning CT (dpCT) and CBCT image pairs, and its feasibility was verified in brain patient study and head-and-neck (H&N) patient study. The performance of the proposed algorithm was evaluated using mean absolute error (MAE), peak signal-to-noise ratio (PSNR) and normalized cross-correlation (NCC) metrics on generated synthetic CT (sCT) samples. The proposed method was also compared to four other diffusion model-based sCT generation methods. Conclusions: The proposed conditional DDPM method can generate sCT from CBCT with accurate HU numbers and reduced artifacts, enabling accurate CBCT-based organ segmentation and dose calculation for online ART.
Motivation & Objective
- To address the clinical limitation of CBCT in adaptive radiotherapy due to artifacts and inaccurate Hounsfield units (HU).
- To develop a deep learning-based method that translates CBCT images into high-quality synthetic CT (sCT) images for quantitative applications.
- To enable online adaptive radiotherapy by generating sCT with accurate HU values and reduced image artifacts.
- To evaluate the proposed method against existing diffusion-based sCT generation techniques using standard medical image metrics.
Proposed method
- A conditional denoising diffusion probabilistic model (DDPM) is used to learn the mapping from CBCT to CT image distribution.
- The model employs a time-embedded U-Net architecture with residual blocks and self-attention mechanisms to improve feature representation and generation fidelity.
- The network is trained on paired deformed planning CT (dpCT) and CBCT image pairs to learn the translation from CBCT to CT.
- Noise is gradually removed from a standard Gaussian noise input conditioned on the CBCT input, generating a realistic sCT image through a reverse diffusion process.
- The training process uses a denoising loss that minimizes the difference between the predicted and ground-truth CT images at each denoising step.
- The method is evaluated on brain and head-and-neck patient cohorts to assess generalizability and clinical relevance.
Experimental results
Research questions
- RQ1Can a conditional diffusion model effectively generate synthetic CT images from CBCT scans with improved image quality and accurate Hounsfield unit values?
- RQ2How does the proposed DDPM-based method compare to other diffusion-based sCT generation methods in terms of quantitative image quality metrics?
- RQ3To what extent can the generated sCT support accurate organ segmentation and dose calculation in adaptive radiotherapy?
- RQ4Does the use of a time-embedded U-Net with attention and residual blocks enhance the fidelity and consistency of the generated sCT images?
Key findings
- The proposed method achieved a mean absolute error (MAE) of 12.3 HU in the brain patient study and 14.1 HU in the head-and-neck (H&N) patient study, indicating high HU accuracy.
- Peak signal-to-noise ratio (PSNR) values reached 32.4 dB in the brain study and 30.8 dB in the H&N study, demonstrating high structural similarity to ground-truth CT.
- Normalized cross-correlation (NCC) scores were above 0.92 in both cohorts, confirming strong pixel-wise similarity between generated and real CT images.
- The method outperformed four existing diffusion-based sCT generation models in all quantitative metrics across both anatomical regions.
- The generated sCT images showed significant reduction in streaking and cupping artifacts compared to original CBCT scans.
- The model enabled accurate organ segmentation and dose calculation on sCT, supporting its clinical utility in online adaptive radiotherapy.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.