[Paper Review] Characterisation of silicon photomultipliers based on statistical analysis of pulse-shape and time distributions
This paper presents a statistical method for characterizing silicon photomultipliers (SiPMs) using pulse-shape and time distribution analysis to accurately measure photon detection efficiency (PDE), correlated noise probabilities, gain, and time constants. By combining oscilloscope-based waveform analysis with IV curve measurements, the authors reduce PDE uncertainty to ~3.5%—a significant improvement over prior methods—enabling precise SiPM evaluation for high-precision applications like the LHCb SciFi tracker.
A detailed and accurate characterisation of silicon photomultiplier detectors is required for a better understanding of the signal and noise in many applications. The collected information is a valuable feedback to the manufacturers in their attempt to improve the performances. In this paper, we provide a detailed description of how to characterise these photo-detectors. The correlated noise probabilities, the important time constants and the photon detection efficiency are obtained with a statistical analysis of pulse-shape and time distributions. The method is tested with different detectors. The quench resistor, the breakdown voltage and the dark count rate are measured from IV characteristics.
Motivation & Objective
- To develop a robust, statistically grounded method for characterizing SiPMs under varying bias and temperature conditions.
- To accurately measure key parameters such as photon detection efficiency (PDE), correlated noise probabilities, and time constants in SiPMs.
- To reduce systematic uncertainty in PDE measurements by eliminating gain-dependent errors through a pulse-frequency-based method.
- To enable reliable SiPM performance evaluation in high-radiation environments, such as the LHCb SciFi tracker.
- To provide feedback to manufacturers for improving SiPM design through detailed, data-driven characterization.
Proposed method
- Waveform data from SiPMs are acquired using a fast preamplifier and 1 GHz oscilloscope within an EMI-shielded enclosure to minimize electronic noise.
- Statistical analysis of pulse shapes classifies correlated noise types, including after-pulses, direct and delayed crosstalk, using a ROOT-based framework.
- The PDE is measured via two methods: current-based (with gain correction) and pulse-frequency-based (eliminating gain dependence).
- The frequency-based method computes PDE using recorded pulse frequency at 0.6 PE threshold, correcting for correlated noise via delayed pulse counting.
- IV scans are used to extract breakdown voltage (V_BD), dark count rate (f_DCR), and quench resistor (R_Q) from current-voltage characteristics.
- Temperature stabilization to ±0.5 K is applied to minimize gain drift, with thermal corrections applied when necessary.
Experimental results
Research questions
- RQ1How can photon detection efficiency (PDE) be measured with minimal systematic uncertainty in SiPMs?
- RQ2What is the contribution of correlated noise—after-pulses, crosstalk, and delayed pulses—to SiPM signal distortion?
- RQ3How does the pulse-shape and time distribution analysis enable accurate separation of primary and correlated noise events?
- RQ4Can the PDE uncertainty be reduced below 4% by eliminating gain measurement dependence?
- RQ5How do temperature and over-voltage (ΔV) affect key SiPM parameters like PDE, f_DCR, and recovery time?
Key findings
- The pulse-frequency-based PDE measurement reduces total uncertainty to ~3.5%, down from ~6% in the current-based method, primarily by eliminating gain-related error.
- The method achieves 1% accuracy in correlated noise probability measurements, validated across multiple SiPM types including H2017, KETEK, SensL, and FBK.
- At ΔV = 3.5 V, a 0.5 °C temperature drift causes only 0.8% gain variation, highlighting the importance of temperature stability for high-precision measurements.
- Cooling SiPMs to -40 °C reduces the dark count rate by a factor of 100, enabling single-photon detection in high-radiation environments.
- The PDE values from the frequency-based method agree with Hamamatsu HPK measurements within 2% at nominal operating voltage, confirming cross-validation accuracy.
- The method successfully characterizes SiPMs with pixel sizes as small as (25 μm)², demonstrating applicability to high-density multichannel arrays.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.