[Paper Review] Clog mitigation in a microfluidic array via pulsatile flows

Brian Dincau, Connor Tang|arXiv (Cornell University)|Jan 15, 2022
Microfluidic and Bio-sensing TechnologiesEngineering5 citations
TL;DR

This study demonstrates that pulsatile flows significantly delay clogging in microfluidic arrays of parallel channels by leveraging dynamic shear to dislodge particles and disrupt filter cake growth. At 0.1 Hz and 0.5P₀ amplitude, pulsation nearly doubles the filter half-life compared to steady flow, with benefits diminishing at lower frequencies due to mismatched timescales between pulsation and clogging dynamics.

ABSTRACT

Clogging is a common obstacle encountered during the transport of suspensions and represents a significant energy and material cost across applications, including water purification, irrigation, biopharmaceutical processing, and aquifer recharge. Pulsatile pressure-driven flows can help mitigate clogging when compared to steady flows. Here, we study experimentally the influence of the amplitude of pulsation $0.25\,P_0 \leq δP \leq 1.25\,P_0$, where $P_0$ is the mean pressure, and of the frequency of pulsation $10^{-3}\,{ m Hz} \leq f \leq 10^{-1}\,{ m Hz}$ on clog mitigation in a microfluidic array of parallel channels using a dilute suspension of colloidal particles. The array geometry is representative of a classical filter, with parallel pores that clog over time, yielding a filter cake that continues to grow and can interact with other pores. We combine flow rate measurements with direct visualizations at the pore scale to correlate the observed clogging dynamics with the changes in flow rate. We observe that all pulsatile amplitudes at $0.1$ Hz yield increased throughput compared to steady flows. The rearrangement of particles when subject to a dynamic shear environment can delay the clogging of a pore or even remove an existing clog. However, this benefit is drastically reduced at $10^{-2}$ Hz and disappears at $10^{-3}$ Hz as the pulsatile timescale becomes too large compared to the timescale associated with the clogging and the growth of the filter cakes in this system. The present study demonstrates that pulsatile flows are a promising method to delay clogging at both the pore and system scale.

Motivation & Objective

  • To investigate how pulsatile pressure-driven flows mitigate clogging in microfluidic arrays of parallel channels.
  • To identify the physical mechanisms—such as particle detachment and filter cake rearrangement—underlying clog mitigation via pulsation.
  • To determine the optimal pulsation amplitude and frequency for maximizing throughput and delaying clogging in dilute colloidal suspensions.
  • To evaluate the role of flow reversal in unclogging, particularly in adjacent-channel systems where inter-channel interactions occur.
  • To establish a systematic link between pulsatile flow parameters and clogging dynamics at both pore and system scales.

Proposed method

  • Experiments were conducted using a microfluidic array with parallel channels representative of a filter, subject to controlled pulsatile pressure inputs.
  • Pulsation amplitude was varied from 0.25P₀ to 1.25P₀, and frequency from 10⁻³ Hz to 10⁻¹ Hz, with P₀ as the mean pressure.
  • System-wide flow rate was measured continuously to track clogging progression and calculate filter half-life (time to 50% clogging).
  • High-speed imaging and direct pore-scale visualization were used to observe particle dynamics, filter cake formation, and ejection events.
  • The clogging ratio was defined as the fraction of channels that are clogged, enabling quantitative comparison across pulsation conditions.
  • Flow reversal was tested at δP = 1.25P₀ to assess its ability to resuspend and remove particles from filter cakes.

Experimental results

Research questions

  • RQ1How does pulsation amplitude influence clog mitigation in a microfluidic array of parallel channels?
  • RQ2What is the role of pulsation frequency in delaying clogging, and at what frequency is the benefit maximized?
  • RQ3Can flow reversal during pulsation lead to active unclogging of already clogged channels?
  • RQ4How do inter-channel interactions affect clogging dynamics during pulsatile flow, especially under flow reversal?
  • RQ5What physical mechanisms at the pore scale—such as particle detachment or filter cake rearrangement—explain the observed clog mitigation?

Key findings

  • All pulsation amplitudes tested at 0.1 Hz significantly increased throughput compared to steady flow, with the highest improvement observed at δP = 0.5P₀.
  • At 0.1 Hz, the filter half-life nearly doubled compared to steady flow, reaching approximately 10,000 seconds under optimal pulsation (δP = 0.5P₀, f = 0.1 Hz).
  • At 10⁻³ Hz, pulsation provided no measurable benefit over steady flow, as the timescale of pulsation was too slow relative to clogging dynamics.
  • Pulsation enabled particle detachment from walls and partial restoration of flow through filter cake rearrangement, phenomena absent in steady flow.
  • Flow reversal (δP = 1.25P₀) induced a unique unclogging mechanism by resuspending particles in filter cakes, but this did not significantly improve filter half-life due to inter-channel interference.
  • The effectiveness of pulsation is critically dependent on matching the pulsation frequency to the clogging timescale; low frequencies fail to disrupt clogging dynamics.