[Paper Review] Compact storage ring to search for the muon electric dipole moment
This paper proposes a compact storage ring with an orbit radius under 0.5 m to measure the muon electric dipole moment (EDM) using the 'frozen spin' technique, achieving a statistical sensitivity of $5 \times 10^{-23}~{}\text{e~{}cm}$ at existing muon facilities within one year, and potentially $5 \times 10^{-25}~{}\text{e~{}cm}$ at future high-intensity sources, demonstrating a viable path for direct charged-particle EDM searches.
We present the concept of a compact storage ring of less than 0.5 m orbit radius to search for the electric dipole moment of the muon ($d_μ$) by adapting the "frozen spin" method. At existing muon facilities a statistics limited sensitivity of $d_μ\sim 5 imes 10^{-23} \ecm$ can be achieved within one year of data taking. Reaching this precision would demonstrate the viability of this novel technique to directly search for charged particle EDMs and already test a number of Standard Model extensions. At a future, high-power muon facility a statistical reach of $d_μ\sim 5 imes 10^{-25} \ecm$ seems realistic with this setup.
Motivation & Objective
- To develop a compact, table-top storage ring setup to directly measure the muon electric dipole moment (EDM), a key probe for new physics beyond the Standard Model.
- To demonstrate the feasibility of the 'frozen spin' method for charged particles, particularly muons, in a small-scale, high-precision environment.
- To achieve a sensitivity improvement of over three orders of magnitude compared to the current best limit of $1.8 \times 10^{-19}~{}\text{e~{}cm}$.
- To test models predicting enhanced muon EDMs due to flavor violation or CP-violating new physics, especially in light of the $g-2$ anomaly.
- To establish a scalable experimental framework that can be upgraded to reach $5 \times 10^{-25}~{}\text{e~{}cm}$ sensitivity with future high-power muon sources.
Proposed method
- The experiment uses a compact storage ring with an orbit radius less than 0.5 m to confine muons in a magnetic field while applying a radial electric field to cancel the anomalous magnetic moment precession.
- The 'frozen spin' technique is applied by tuning the radial electric field to $E \simeq aB\beta\gamma^2$ to suppress the $g-2$ precession, leaving only spin precession due to a non-zero EDM.
- The EDM signal is measured via the up–down counting asymmetry in positron decay products, which grows linearly with time if $d_{\mu} \neq 0$, with the rate proportional to $\eta \propto d_{\mu}$.
- The method relies on injecting muons one at a time to minimize systematic errors and ensure statistical dominance in sensitivity.
- Systematic errors from residual longitudinal magnetic fields and detector misalignments are analyzed and shown to be controllable with stringent but achievable field and position stability requirements.
- The experimental cycle is designed to be approximately two muon lifetimes to optimize signal-to-noise and allow for background suppression.
Experimental results
Research questions
- RQ1Can a compact storage ring with an orbit radius under 0.5 m achieve sufficient sensitivity to measure the muon EDM with a statistical uncertainty below $10^{-23}~{}\text{e~{}cm}$?
- RQ2Is the 'frozen spin' technique viable for charged particles like muons in a small-scale, high-field environment?
- RQ3What level of systematic errors from magnetic field inhomogeneities and detector misalignments can be tolerated to reach a sensitivity of $5 \times 10^{-23}~{}\text{e~{}cm}$?
- RQ4Can the proposed setup unambiguously distinguish a true EDM signal from false signals due to residual longitudinal magnetic fields or beam position drifts?
- RQ5What is the projected sensitivity gain when scaling the experiment to future high-intensity muon sources with $10^4$ muons per bunch and 100 kHz repetition rates?
Key findings
- A sensitivity of $5 \times 10^{-23}~{}\text{e~{}cm}$ for the muon EDM is achievable at existing muon facilities, such as the PSI µE1 beamline, within one year of data taking using a one-muon-at-a-time injection scheme.
- This sensitivity represents an improvement of over three orders of magnitude compared to the current best limit of $1.8 \times 10^{-19}~{}\text{e~{}cm}$.
- At a future high-power muon facility with $10^4$ muons per bunch and 100 kHz repetition rate, a statistical sensitivity of $5 \times 10^{-25}~{}\text{e~{}cm}$ is realistically attainable.
- Systematic errors from longitudinal magnetic fields are bounded by $B_L/B_T < 6 \times 10^{-9}$ to match the statistical uncertainty, corresponding to a current of 13 mA or a field change of 2.5 GV/m/s.
- Beam position drifts must be limited to $d\delta/dt < 0.1~\mu\text{m}/\gamma\tau$ to avoid false EDM signals, with the false signal's momentum dependence distinguishable from the true signal.
- The compact design simplifies field shimming and systematic control, making it feasible to achieve the required precision with relaxed tolerances compared to larger rings.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.