Skip to main content
QUICK REVIEW

[Paper Review] Comparison of 1D and 3D Models for the Estimation of Fractional Flow Reserve

Pablo Blanco, Carlos A. Bulant|arXiv (Cornell University)|May 29, 2018
Coronary Interventions and DiagnosticsMedicine22 references11 citations
TL;DR

This study validates one-dimensional (1D) coronary hemodynamic models as accurate surrogates for time-consuming 3D simulations in estimating fractional flow reserve (FFR). Using patient-specific 3D coronary geometries from CCTA and IVUS, the authors show that 1D models achieve near-perfect agreement with 3D FFR predictions (mean difference: 0.00 ± 0.03) and excellent diagnostic performance (AUC: 0.97, accuracy: 0.98), demonstrating that 1D models can reliably replace 3D simulations in clinical FFR estimation with drastically reduced computational cost.

ABSTRACT

In this work we propose to validate the predictive capabilities of one-dimensional (1D) blood flow models with full three-dimensional (3D) models in the context of patient-specific coronary hemodynamics in hyperemic conditions. Such conditions mimic the state of coronary circulation during the acquisition of the Fractional Flow Reserve (FFR) index. Demonstrating that 1D models accurately reproduce FFR estimates obtained with 3D models has implications in the approach to computationally estimate FFR. To this end, a sample of 20 patients was employed from which 29 3D geometries of arterial trees were constructed, 9 obtained from coronary computed tomography angiography (CCTA) and 20 from intra-vascular ultrasound (IVUS). For each 3D arterial model, a 1D counterpart was generated. The same outflow and inlet pressure boundary conditions were applied to both (3D and 1D) models. In the 1D setting, pressure losses at stenoses and bifurcations were accounted for through specific lumped models. Comparisons between 1D models ($ ext{FFR}_{ ext{1D}}$) and 3D models ($ ext{FFR}_{ ext{3D}}$) were performed in terms of predicted $ ext{FFR}$ value. Compared to $ ext{FFR}_{ ext{3D}}$, $ ext{FFR}_{ ext{1D}}$ resulted with a difference of 0.00$\pm$0.03 and overall predictive capability AUC, Acc, Spe, Sen, PPV and NPV of 0.97, 0.98, 0.90, 0.99, 0.82, and 0.99, with an FFR threshold of 0.8. We conclude that inexpensive $ ext{FFR}_{ ext{1D}}$ simulations can be reliably used as a surrogate of demanding $ ext{FFR}_{ ext{3D}}$ computations.

Motivation & Objective

  • To validate 1D coronary hemodynamic models as reliable surrogates for 3D simulations in patient-specific FFR estimation under hyperemic conditions.
  • To assess whether 1D models can accurately predict FFR values comparable to gold-standard 3D simulations in real patient anatomies.
  • To evaluate the impact of different lumped parameter models (e.g., stenosis and junction models) on 1D FFR prediction accuracy.
  • To determine if a one-fits-all parameter approach for stenosis modeling is sufficient for accurate FFR estimation in diverse patient-specific geometries.
  • To demonstrate the clinical feasibility of 1D FFR simulations by showing their computational efficiency and diagnostic equivalence to 3D models.

Proposed method

  • Constructed 29 patient-specific 3D coronary arterial models from CCTA (n=9) and IVUS (n=20) imaging data.
  • Generated corresponding 1D centerline models from the 3D geometries to enable 1D simulations.
  • Applied identical inlet and outlet pressure boundary conditions to both 1D and 3D models to ensure consistent hemodynamic conditions.
  • Incorporated lumped-parameter models for stenoses and bifurcations in 1D simulations to account for local pressure losses.
  • Performed numerical simulations under hyperemic conditions to mimic clinical FFR measurement protocols.
  • Compared 1D-predicted FFR (FFR₁D) with 3D-predicted FFR (FFR₃D) using statistical metrics including Bland-Altman analysis, correlation, and classification performance.

Experimental results

Research questions

  • RQ1Can 1D coronary hemodynamic models accurately predict FFR values when compared to 3D simulations in patient-specific coronary geometries?
  • RQ2Does a one-fits-all parameter setting for stenosis modeling in 1D models yield reliable FFR predictions across diverse anatomical variations?
  • RQ3How do different junction modeling strategies (standard vs. dissipative) affect the accuracy of 1D FFR predictions?
  • RQ4Is the diagnostic performance of 1D FFR (e.g., AUC, sensitivity, specificity) comparable to that of 3D FFR when using clinically relevant anatomical locations?
  • RQ5Can 1D FFR simulations achieve sufficient accuracy to replace 3D simulations in clinical settings, given their significantly lower computational cost?

Key findings

  • The mean difference between 1D-predicted FFR (FFR₁D) and 3D-predicted FFR (FFR₃D) was 0.00 ± 0.03, indicating near-perfect agreement.
  • The area under the ROC curve (AUC) for 1D FFR prediction was 0.97, demonstrating excellent discriminatory power.
  • Classification accuracy for detecting hemodynamically significant stenoses (FFR < 0.8) reached 0.98, with sensitivity of 0.99 and specificity of 0.90.
  • Positive predictive value (PPV) was 0.82 and negative predictive value (NPV) was 0.99, indicating strong reliability in clinical decision-making.
  • The use of dissipative junction models slightly improved FFR₁D accuracy, particularly at clinically relevant distal locations, though the standard junction model also performed well.
  • Even with low prevalence of positive FFR₃D cases (0.06), results remained robust when re-evaluated on a subset with higher prevalence (0.28), confirming the consistency of 1D model performance.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.