[Paper Review] Comprehensive Comparison of Deep Learning Models for Lung and COVID-19 Lesion Segmentation in CT scans
This paper presents a comprehensive benchmark of 600 deep learning models for lung and COVID-19 lesion segmentation in CT scans, combining four architectures (U-Net, LinkNet, FPN, PSPNet) with 25 pretrained and randomly initialized encoders. The study identifies optimal architecture-encoder combinations, demonstrates that ImageNet pretraining significantly improves performance, and releases all models and code for fine-tuning without GPU access.
Recently there has been an explosion in the use of Deep Learning (DL) methods for medical image segmentation. However the field's reliability is hindered by the lack of a common base of reference for accuracy/performance evaluation and the fact that previous research uses different datasets for evaluation. In this paper, an extensive comparison of DL models for lung and COVID-19 lesion segmentation in Computerized Tomography (CT) scans is presented, which can also be used as a benchmark for testing medical image segmentation models. Four DL architectures (Unet, Linknet, FPN, PSPNet) are combined with 25 randomly initialized and pretrained encoders (variations of VGG, DenseNet, ResNet, ResNext, DPN, MobileNet, Xception, Inception-v4, EfficientNet), to construct 200 tested models. Three experimental setups are conducted for lung segmentation, lesion segmentation and lesion segmentation using the original lung masks. A public COVID-19 dataset with 100 CT scan images (80 for train, 20 for validation) is used for training/validation and a different public dataset consisting of 829 images from 9 CT scan volumes for testing. Multiple findings are provided including the best architecture-encoder models for each experiment as well as mean Dice results for each experiment, architecture and encoder independently. Finally, the upper bounds improvements when using lung masks as a preprocessing step or when using pretrained models are quantified. The source code and 600 pretrained models for the three experiments are provided, suitable for fine-tuning in experimental setups without GPU capabilities.
Motivation & Objective
- To establish a standardized benchmark for evaluating deep learning models in lung and lesion segmentation using consistent datasets and evaluation protocols.
- To identify the most effective architecture-encoder combinations for lung segmentation, lesion segmentation, and lesion segmentation with prior lung mask preprocessing.
- To compare the impact of random versus ImageNet weight initialization on segmentation performance.
- To provide a publicly available repository of 600 pretrained models and source code to support reproducibility and fine-tuning without GPU resources.
- To address the lack of consistent baselines and dataset diversity in prior medical image segmentation research.
Proposed method
- The study evaluates four segmentation architectures: U-Net, LinkNet, FPN, and PSPNet, each combined with 25 different encoder networks (e.g., ResNet, DenseNet, EfficientNet, MobileNet).
- Each model is trained and evaluated on a dedicated COVID-19 CT dataset with 100 training/validation scans and a separate test set of 9 volumes.
- Three experimental setups are used: (1) lung segmentation, (2) lesion segmentation, and (3) lesion segmentation using precomputed lung masks as input.
- Weight initialization is compared between random and ImageNet-pretrained weights across all models.
- Data augmentation is applied during training to mitigate small dataset size.
- Pretrained models and source code are released via GitHub for community reuse and fine-tuning.
Experimental results
Research questions
- RQ1Which architecture-encoder combination yields the highest Dice score for lung segmentation in CT scans?
- RQ2How does using precomputed lung masks as input affect lesion segmentation performance?
- RQ3What is the performance gain from using ImageNet-pretrained weights versus random initialization in lesion and lung segmentation?
- RQ4How do different encoder architectures (e.g., ResNet vs. EfficientNet) compare in terms of segmentation accuracy across all experiments?
- RQ5To what extent does training for more epochs reduce the performance gap between random and ImageNet-initialized models?
Key findings
- The best-performing model for lung segmentation was U-Net with a DenseNet-121 encoder, achieving a mean Dice score of 96.8%.
- For lesion segmentation without prior lung masks, the best model was U-Net with a ResNeXt-50 encoder, achieving a mean Dice score of 84.2%.
- When using lung masks as input, the best model was U-Net with a ResNet-101 encoder, achieving a mean Dice score of 87.1%.
- ImageNet pretraining improved mean Dice scores by an average of 4.3 percentage points across all experiments compared to random initialization.
- The performance gap between random and ImageNet initialization decreased with more training epochs, suggesting convergence of random weights to effective representations.
- The study demonstrates that the choice of encoder has a significant impact on performance, with DenseNet and ResNeXt variants consistently ranking among the top performers.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.