[Paper Review] Consensus Neural Network for Medical Imaging Denoising with Only Noisy Training Samples
This paper proposes a consensus neural network for medical image denoising that trains exclusively on noisy samples by leveraging two independent noise realizations of the same image. Using a novel consensus loss function and a theoretical foundation proving equivalence to supervised training under zero-mean, uncorrelated noise, the method achieves state-of-the-art performance in unsupervised denoising on low-dose CT and undersampled MR datasets, outperforming Noise2noise and iterative methods while preserving fine structures.
Deep neural networks have been proved efficient for medical image denoising. Current training methods require both noisy and clean images. However, clean images cannot be acquired for many practical medical applications due to naturally noisy signal, such as dynamic imaging, spectral computed tomography, arterial spin labeling magnetic resonance imaging, etc. In this paper we proposed a training method which learned denoising neural networks from noisy training samples only. Training data in the acquisition domain was split to two subsets and the network was trained to map one noisy set to the other. A consensus loss function was further proposed to efficiently combine the outputs from both subsets. A mathematical proof was provided that the proposed training scheme was equivalent to training with noisy and clean samples when the noise in the two subsets was uncorrelated and zero-mean. The method was validated on Low-dose CT Challenge dataset and NYU MRI dataset and achieved improved performance compared to existing unsupervised methods.
Motivation & Objective
- To address the challenge of training deep denoising networks in medical imaging when clean reference images are unavailable due to inherent noise in modalities like dynamic CT, PET, and ASL-MRI.
- To extend the Noise2noise framework by providing a rigorous mathematical proof of its equivalence to supervised learning under specific noise conditions.
- To develop a consensus loss function that efficiently combines two noisy realizations of the same image during training, improving denoising performance over existing unsupervised methods.
- To validate the method on real-world medical imaging datasets—Low-dose CT and NYU MRI—where clean images are not available during training.
- To enable deployment in clinical workflows without modifying scanner acquisition pipelines by training a separate network to map noisy inputs to consensus outputs.
Proposed method
- The method splits each noisy input into two independent noise realizations, treating them as source and target for a denoising network.
- A novel consensus loss function is introduced that jointly optimizes the network to predict one noisy realization from the other, leveraging both for improved feature learning.
- Theoretical analysis proves that the proposed training scheme is equivalent to supervised learning when the noise in the two realizations is zero-mean and uncorrelated, formalizing the conditions under which Noise2noise works.
- The network is trained using a L2 loss between the predicted image and the second noisy realization, with the assumption that the conditional expectation of the second noise given the first is zero.
- After training, the consensus network can be deployed in inference mode using only a single noisy input, with no need for paired data during deployment.
- The framework is compatible with existing reconstruction workflows, as a separate network can be trained in a supervised manner to map noisy inputs to the consensus network's output.
Experimental results
Research questions
- RQ1Under what conditions is Noise2noise training equivalent to supervised denoising with clean images?
- RQ2Can a consensus loss function be designed to effectively utilize two independent noisy realizations of the same image to improve denoising performance?
- RQ3Does the proposed method outperform existing unsupervised denoising methods like Noise2noise on real medical imaging datasets with challenging noise characteristics?
- RQ4Can the method preserve fine anatomical structures and textures while reducing noise in low-dose and undersampled imaging?
- RQ5Is the proposed framework deployable in clinical settings without requiring changes to scanner acquisition protocols?
Key findings
- On the Low-dose CT Challenge dataset, the proposed method achieved the highest SSIM (87.1 ± 3.4) among unsupervised methods, outperforming Noise2noise (84.2 ± 4.6) and matching the performance of supervised Noise2clean (87.7 ± 3.3).
- The proposed method achieved an RMSE of 18.4 ± 2.9 HU on CT data, slightly higher than Noise2noise (17.4 ± 3.2), but with significantly better preservation of small lesions and textures.
- On the NYU MRI dataset with 4× undersampling, the proposed method achieved the lowest RMSE (23.4 ± 4.2 × 10⁻³) and highest SSIM (95.2 ± 0.6), outperforming Noise2noise (RMSE: 27.7 ± 6.3, SSIM: 94.6 ± 1.3).
- Visual comparisons showed that the proposed method preserved structural details and reduced noise and artifacts more effectively than Zero-filling, SENSE, and Noise2noise, with results very close to those of supervised Noise2clean.
- The method demonstrated robustness to both local noise (in CT) and non-local undersampling artifacts (in MR), indicating broad applicability across different noise models.
- The consensus network successfully mitigated artifacts caused by noise correlation through regularization, maintaining high image quality even when noise independence was partially violated.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.