Skip to main content
QUICK REVIEW

[Paper Review] Constraints on directionality effect of nuclear recoils in a liquid argon time projection chamber

20k Collaboration, P. Agnes|arXiv (Cornell University)|Jul 28, 2023
Dark Matter and Cosmic PhenomenaPhysics and Astronomy2 citations
TL;DR

This study investigates directional sensitivity in liquid argon time projection chambers (TPCs) for dark matter detection by measuring neutron-induced nuclear recoils at known angles. Using data from the ReD experiment at INFN-LNS, a likelihood analysis with the Cataudella charge recombination model found no significant directionality effect, setting an upper limit of R < 1.072 (90% CL) on the ionization cloud aspect ratio R = 1.037 ± 0.027.

ABSTRACT

The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils (NR) produced in a target material from the WIMP elastic scattering. A promising experimental strategy for direct dark matter search employs argon dual-phase time projection chambers (TPC). One of the advantages of the TPC is the capability to detect both the scintillation and charge signals produced by NRs. Furthermore, the existence of a drift electric field in the TPC breaks the rotational symmetry: the angle between the drift field and the momentum of the recoiling nucleus can potentially affect the charge recombination probability in liquid argon and then the relative balance between the two signal channels. This fact could make the detector sensitive to the directionality of the WIMP-induced signal, enabling unmistakable annual and daily modulation signatures for future searches aiming for discovery. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud, and data were taken with 72 keV NRs of known recoil directions. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is estimated to be 1.037 +/- 0.027 and the upper limit is R &lt; 1.072 with 90% confidence level

Motivation & Objective

  • To test whether the drift electric field in liquid argon TPCs induces direction-dependent charge recombination in nuclear recoils.
  • To assess the potential for directional dark matter detection via angular modulation signatures.
  • To validate the Cataudella charge recombination model using experimental data from neutron irradiation.
  • To set constraints on the aspect ratio R of the initial ionization cloud in liquid argon.

Proposed method

  • Irradiated a ReD TPC with 72 keV neutrons at INFN-LNS to produce nuclear recoils with known recoil directions.
  • Measured both scintillation (S1) and electroluminescence (S2) signals to determine charge recombination behavior.
  • Applied a likelihood statistical analysis to compare predicted S2 signals from the Cataudella directionality model with experimental data.
  • Split data into four angular subsets based on recoil direction θr to test for directional deviations.
  • Used machine learning techniques to analyze prediction errors and assess consistency with the null hypothesis of no directionality.
  • Calculated p-value = 0.23 from χ² test and derived 90% confidence upper limit on R.

Experimental results

Research questions

  • RQ1Does the drift electric field in liquid argon TPCs induce a direction-dependent charge recombination effect in nuclear recoils?
  • RQ2Can the detector response to nuclear recoils vary with the angle between the recoil momentum and the drift field?
  • RQ3Is the Cataudella charge recombination model consistent with experimental data from known-direction nuclear recoils?
  • RQ4What is the upper limit on the ionization cloud aspect ratio R under the assumption of no directionality effect?

Key findings

  • No significant directionality effect was observed in the ReD data, with a p-value of 0.23 from the χ² test.
  • The aspect ratio R of the initial ionization cloud was measured as R = 1.037 ± 0.027.
  • The 90% confidence level upper limit on R is R < 1.072.
  • The data are consistent with the null hypothesis of no directional sensitivity.
  • A sensitivity study confirmed that a 7% S1 difference (as hinted by SCENE) would have been detected at 3.2σ level with this dataset.
  • The results support the validity of the Cataudella charge recombination model and constrain directional dark matter search strategies.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.