Skip to main content
QUICK REVIEW

[Paper Review] Cortical analysis of heterogeneous clinical brain MRI scans for large-scale neuroimaging studies

Karthik Gopinath, Douglas N. Greve|arXiv (Cornell University)|May 2, 2023
Medical Image Segmentation TechniquesComputer Science3 citations
TL;DR

This paper presents a novel, retraining-free method for cortical surface reconstruction, registration, parcellation, and thickness estimation from any clinical brain MRI scan—regardless of resolution, contrast, or orientation. By combining a domain-randomized CNN to predict signed distance functions (SDFs) of white matter and pial surfaces with a geometry processing module enforcing topological and geometric constraints, the method enables accurate large-scale neuroimaging analysis on heterogeneous clinical data, outperforming existing methods in detecting group differences and aging effects.

ABSTRACT

Surface analysis of the cortex is ubiquitous in human neuroimaging with MRI, e.g., for cortical registration, parcellation, or thickness estimation. The convoluted cortical geometry requires isotropic scans (e.g., 1mm MPRAGEs) and good gray-white matter contrast for 3D reconstruction. This precludes the analysis of most brain MRI scans acquired for clinical purposes. Analyzing such scans would enable neuroimaging studies with sample sizes that cannot be achieved with current research datasets, particularly for underrepresented populations and rare diseases. Here we present the first method for cortical reconstruction, registration, parcellation, and thickness estimation for clinical brain MRI scans of any resolution and pulse sequence. The methods has a learning component and a classical optimization module. The former uses domain randomization to train a CNN that predicts an implicit representation of the white matter and pial surfaces (a signed distance function) at 1mm isotropic resolution, independently of the pulse sequence and resolution of the input. The latter uses geometry processing to place the surfaces while accurately satisfying topological and geometric constraints, thus enabling subsequent parcellation and thickness estimation with existing methods. We present results on 5mm axial FLAIR scans from ADNI and on a highly heterogeneous clinical dataset with 5,000 scans. Code and data are publicly available at https://surfer.nmr.mgh.harvard.edu/fswiki/recon-all-clinical

Motivation & Objective

  • To enable cortical analysis on the vast majority of clinical brain MRI scans, which are typically anisotropic, heterogeneous in contrast and resolution, and unsuitable for standard research pipelines.
  • To overcome the limitations of existing deep learning methods that require specific scan characteristics (e.g., 1mm isotropic MPRAGEs) and fail on clinical scans.
  • To develop a method that maintains topological correctness and geometric accuracy across diverse clinical acquisitions without retraining.
  • To facilitate large-scale neuroimaging studies on underrepresented populations and rare diseases by unlocking access to retrospective clinical scan archives.

Proposed method

  • A convolutional neural network (CNN) is trained using domain randomization to predict isotropic signed distance functions (SDFs) for white matter and pial surfaces, independent of input scan resolution or pulse sequence.
  • The training data are synthetic, generated from FreeSurfer reconstructions of 1mm isotropic T1 scans (e.g., from the HCP dataset), with random variations in resolution, contrast, and orientation applied during each training batch.
  • A classical geometry processing module then computes topologically correct, non-self-intersecting cortical surface meshes from the predicted SDFs, ensuring spherical topology and regularity.
  • The method supports downstream tasks such as spherical registration, parcellation (e.g., Desikan-Killiany), and cortical thickness estimation using established tools like FreeSurfer.
  • The approach is end-to-end: from any input MRI (axial, coronal, sagittal, any resolution or contrast) to a fully reconstructed, parcellated, and registered cortical surface.
  • The method is retraining-free and generalizes across diverse clinical scan protocols, including 5mm axial FLAIR and heterogeneous TSE-T1 scans.

Experimental results

Research questions

  • RQ1Can a deep learning model robustly predict cortical surface SDFs from highly heterogeneous clinical MRI scans without requiring retraining for each scan type?
  • RQ2How well does the method preserve topological and geometric accuracy when processing anisotropic, low-contrast, or non-isotropic scans?
  • RQ3To what extent can the method detect known neuroimaging biomarkers—such as cortical thinning in aging or group differences in neurodegenerative disease—on clinical scans compared to gold-standard 1mm MPRAGEs?
  • RQ4Can the method achieve reliable parcellation and thickness estimation on a large, heterogeneous clinical dataset with diverse acquisition protocols?
  • RQ5Does the method outperform existing synthesis-based or learning-based approaches in detecting subtle cortical effects in real-world clinical data?

Key findings

  • On 5mm axial FLAIR scans from ADNI, the method detected group differences with an effect size (ES) of 0.64, significantly outperforming SynthSR (ES = 0.32), which lost half the detectable effect.
  • The method successfully detected age-related cortical thinning in the superior-temporal gyrus—particularly in the left hemisphere—where SynthSR failed to detect the effect.
  • On the heterogeneous clinical dataset of 5,000 scans, the method achieved a mean Dice score for parcellation comparable to that of 1mm MPRAGEs, demonstrating high accuracy despite extreme protocol variability.
  • The method recovered one-third of the effect size lost by SynthSR in detecting group differences, indicating superior sensitivity to subtle neuroanatomical changes.
  • In aging analysis, the method detected a linear thinning trend in the superior frontal cortex (ρ = -0.24), though with lower magnitude than the gold-standard MPRAGEs (ρ = -0.55), suggesting room for improvement in noise handling.
  • Despite increased variability in thickness measurements on the clinical dataset, the method enables large-scale analysis of retrospective clinical scans, unlocking new opportunities for rare disease and underrepresented population studies.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.