Skip to main content
QUICK REVIEW

[Paper Review] Coupling weak and strong supervision for classification of prostate cancer histopathology images

Eirini Arvaniti, Manfred Claassen|arXiv (Cornell University)|Nov 16, 2018
AI in cancer detectionComputer Science7 references13 citations
TL;DR

This paper proposes a self-weighted weak supervision approach that jointly trains on a large weakly-labeled whole-slide image dataset (TCGA) and a smaller strongly-labeled tissue microarray dataset (TMA) for prostate cancer Gleason score classification. By using model-predicted confidence scores to dynamically weight weak supervision signals, the method improves generalization and achieves state-of-the-art performance, with an AUC of 0.882 and Kendall’s τ of 0.540 on TCGA WSIs.

ABSTRACT

Automated grading of prostate cancer histopathology images is a challenging task, with one key challenge being the scarcity of annotations down to the level of regions of interest (strong labels), as typically the prostate cancer Gleason score is known only for entire tissue slides (weak labels). In this study, we focus on automated Gleason score assignment of prostate cancer whole-slide images on the basis of a large weakly-labeled dataset and a smaller strongly-labeled one. We efficiently leverage information from both label sources by jointly training a classifier on the two datasets and by introducing a gradient update scheme that assigns different relative importances to each training example, as a means of self-controlling the weak supervision signal. Our approach achieves superior performance when compared with standard Gleason scoring methods.

Motivation & Objective

  • To address the challenge of limited ROI-level Gleason pattern annotations in prostate cancer histopathology by combining weak (patient-level) and strong (patch-level) labels.
  • To improve classification performance on whole-slide images when only a small amount of strongly-labeled data is available alongside a large weakly-labeled dataset.
  • To reduce domain shift between TMA and TCGA datasets through stain transfer and color augmentation.
  • To develop a self-weighting mechanism that adaptively controls the contribution of weak supervision signals based on model confidence.

Proposed method

  • The method jointly trains a ResNet18 classifier on both weakly-labeled (TCGA) and strongly-labeled (TMA) datasets using a two-step gradient update scheme.
  • Weak supervision signals are weighted by per-example confidence scores computed as the predicted probability of the correct weak label, reducing influence from mislabeled or ambiguous patches.
  • Stain transfer and color jittering are applied to mitigate covariate shift between TMA (source) and TCGA (target) datasets.
  • A self-weighted training strategy is implemented via Algorithm 1, alternating between strong and weak label back-propagation with confidence-weighted gradients.
  • Domain adaptation techniques such as MMD, CORAL, and adversarial training are evaluated but found less effective than stain transfer and color augmentation.
  • Performance is evaluated using 5-fold cross-validation with AUC, accuracy, and Kendall’s τ correlation against clinical Gleason score groups.

Experimental results

Research questions

  • RQ1Can combining weak and strong supervision improve classification performance on prostate cancer whole-slide images when only limited ROI-level annotations are available?
  • RQ2How can the influence of noisy or misaligned weak supervision signals be reduced during training?
  • RQ3Which data augmentation and domain adaptation strategies are most effective in mitigating distribution shift between TMA and TCGA histopathology datasets?
  • RQ4Does self-weighting weak supervision signals based on model confidence lead to better generalization than standard or MIL-based weak supervision?
  • RQ5How does the proposed method compare to existing approaches in terms of AUC, accuracy, and correlation with clinical Gleason grading?

Key findings

  • The proposed self-weighted weak supervision (SW-WS) method achieved the highest AUC of 0.882 (±0.024) and Kendall’s τ of 0.540 (±0.032) on TCGA whole-slide images when training on both weak and strong labels.
  • Using only weakly-labeled TCGA data yielded an AUC of 0.814 (±0.057), which improved to 0.845 (±0.065) when strong TMA labels were added, demonstrating the value of strong supervision.
  • The SW-WS method outperformed MIL-based weak supervision (AUC 0.839) and standard weak-only training, indicating that confidence-based weighting is more effective than top-k sampling.
  • Stain transfer and color augmentation were the most effective strategies for reducing covariate shift, outperforming MMD, CORAL, and adversarial domain adaptation.
  • The method achieved a 5.4% absolute improvement in AUC and a 12.5% improvement in Kendall’s τ over the best baseline, showing strong clinical relevance.
  • The model’s predicted WSI scores showed strong correlation with clinical Gleason score groups (τ = 0.540), suggesting clinical utility.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.