[Paper Review] COVID-19 Classification Using Deep Learning Two-Stage Approach
This paper proposes a two-stage deep learning approach (Covid-TSC) for classifying chest X-rays into four categories: COVID-19, normal, opacity, and pneumonia. Using transfer learning with VGG16 and VGG19 on a 20,000+ image dataset, the study finds that a one-shot classification using fine-tuned VGG16 achieves 95% accuracy, outperforming the two-stage method, which suggests the two-stage design did not improve performance as hypothesized.
In this paper, deep-learning-based approaches namely fine-tuning of pretrained convolutional neural networks (VGG16 and VGG19), and end-to-end training of a developed CNN model, have been used in order to classify X-Ray images into four different classes that include COVID-19, normal, opacity and pneumonia cases. A dataset containing more than 20,000 X-ray scans was retrieved from Kaggle and used in this experiment. A two-stage classification approach was implemented to be compared to the one-shot classification approach. Our hypothesis was that a two-stage model will be able to achieve better performance than a one-shot model. Our results show otherwise as VGG16 achieved 95% accuracy using one-shot approach over 5-fold of training. Future work will focus on a more robust implementation of the two-stage classification model Covid-TSC. The main improvement will be allowing data to flow from the output of stage-1 to the input of stage-2, where stage-1 and stage-2 models are VGG16 models fine-tuned on the Covid-19 dataset.
Motivation & Objective
- To develop and evaluate a two-stage deep learning model (Covid-TSC) for classifying chest X-rays into four disease categories: COVID-19, normal, opacity, and pneumonia.
- To compare the performance of the two-stage approach against a one-shot classification method using transfer learning.
- To investigate whether separating classification into two stages—first distinguishing disease from normal, then identifying the specific disease—improves model accuracy and robustness.
- To assess the feasibility of using VGG16 and VGG19 via fine-tuning and end-to-end training for automated COVID-19 diagnosis from X-ray images.
- To identify limitations in the current two-stage design and propose improvements for future implementation.
Proposed method
- A two-stage classification model (Covid-TSC) was designed, where Stage 1 distinguishes normal from disease cases, and Stage 2 classifies disease types (COVID-19, opacity, pneumonia).
- Transfer learning was applied using pre-trained VGG16 and VGG19 models fine-tuned on the COVID-Radiology dataset containing over 20,000 X-ray scans.
- An end-to-end trained CNN model was also developed and compared against the transfer learning models.
- Five-fold cross-validation was used to evaluate model performance, with metrics including accuracy, precision, recall, and F1-score.
- Confusion matrices and classification reports were generated for both stages to analyze model behavior and error patterns.
- Hardware resources (CPU, GPU, RAM) were standardized across experiments to ensure consistent and comparable training times and performance.
Experimental results
Research questions
- RQ1Does a two-stage deep learning approach improve classification accuracy for X-ray images across four classes (COVID-19, normal, opacity, pneumonia) compared to a one-shot approach?
- RQ2Can transfer learning with VGG16 and VGG19 achieve high-performance classification on a limited medical X-ray dataset?
- RQ3What is the impact of model architecture and training strategy (fine-tuning vs. end-to-end) on diagnostic accuracy for COVID-19 detection?
- RQ4Why did the two-stage model underperform compared to the one-shot model, and what design flaws may explain this result?
- RQ5How can the two-stage model be restructured to allow feature flow from Stage 1 to Stage 2 for improved performance?
Key findings
- The one-shot classification using fine-tuned VGG16 achieved 95% accuracy across five-fold cross-validation, significantly outperforming the two-stage approach.
- VGG16 demonstrated a recall of 0.99 for the COVID-19 class, indicating it correctly identified 99% of actual COVID-19 cases.
- The precision for the COVID-19 class was 0.98, meaning 2% of non-COVID-19 images were misclassified as positive.
- Stage 2 of the two-stage model achieved 100% recall for both opacity and pneumonia, and 98% recall for COVID-19, indicating strong detection capability for these classes.
- Despite strong recall, the two-stage model (Covid-TSC) achieved only 82.4% accuracy, which was lower than VGG16’s 95.2% accuracy on the same dataset.
- The two-stage model required less training time (2.10 seconds) than VGG16 (3.14 seconds), but this efficiency did not translate into better performance.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.