Skip to main content
QUICK REVIEW

[Paper Review] CyTran: A Cycle-Consistent Transformer with Multi-Level Consistency for Non-Contrast to Contrast CT Translation

Nicolae-Cătălin Ristea, Andreea-Iuliana Ionescu|arXiv (Cornell University)|Oct 12, 2021
Brain Tumor Detection and ClassificationNeuroscience8 citations
TL;DR

CyTran proposes a cycle-consistent transformer with multi-level consistency for unpaired non-contrast to contrast CT translation, using a hybrid convolutional-transformer architecture and multi-level cycle-consistency losses to generate high-fidelity, artifact-free CT scans. It outperforms state-of-the-art methods in both translation quality and downstream image registration, with human evaluations confirming no introduced visual artifacts.

ABSTRACT

We propose a novel approach to translate unpaired contrast computed tomography (CT) scans to non-contrast CT scans and the other way around. Solving this task has two important applications: (i) to automatically generate contrast CT scans for patients for whom injecting contrast substance is not an option, and (ii) to enhance the alignment between contrast and non-contrast CT by reducing the differences induced by the contrast substance before registration. Our approach is based on cycle-consistent generative adversarial convolutional transformers, for short, CyTran. Our neural model can be trained on unpaired images, due to the integration of a multi-level cycle-consistency loss. Aside from the standard cycle-consistency loss applied at the image level, we propose to apply additional cycle-consistency losses between intermediate feature representations, which enforces the model to be cycle-consistent at multiple representations levels, leading to superior results. To deal with high-resolution images, we design a hybrid architecture based on convolutional and multi-head attention layers. In addition, we introduce a novel data set, Coltea-Lung-CT-100W, containing 100 3D triphasic lung CT scans (with a total of 37,290 images) collected from 100 female patients (there is one examination per patient). Each scan contains three phases (non-contrast, early portal venous, and late arterial), allowing us to perform experiments to compare our novel approach with state-of-the-art methods for image style transfer. Our empirical results show that CyTran outperforms all competing methods. Moreover, we show that CyTran can be employed as a preliminary step to improve a state-of-the-art medical image alignment method. We release our novel model and data set as open source at https://github.com/ristea/cycle-transformer.

Motivation & Objective

  • To address the challenge of generating contrast-enhanced CT scans from non-contrast scans for patients who cannot receive contrast agents.
  • To reduce Hounsfield unit (HU) differences between contrast and non-contrast CT scans to improve image registration accuracy.
  • To develop a robust, artifact-free translation model that preserves anatomical fidelity in medical imaging.
  • To introduce a novel, large-scale triphasic lung CT dataset (Coltea-Lung-CT-100W) for training and benchmarking.
  • To demonstrate that CyTran enhances the performance of state-of-the-art medical image registration pipelines.

Proposed method

  • Introduces a hybrid neural architecture combining convolutional layers and multi-head self-attention mechanisms to handle high-resolution 3D CT scans efficiently.
  • Employs a multi-level cycle-consistency (MLCC) loss that enforces consistency not only at the image level but also at intermediate feature representations.
  • Uses a cycle-consistent generative adversarial network (CycleGAN-style) framework to train on unpaired data, enabling bidirectional translation between non-contrast and contrast CT.
  • Applies a recursive cascaded refinement strategy using ViT-V-Net with CyTran to progressively improve translation quality.
  • Leverages a novel 3D triphasic CT dataset (Coltea-Lung-CT-100W) with 100 female patients and 37,290 images for training and evaluation.
  • Integrates the CyTran model as a preprocessing step to reduce HU differences before image registration, enhancing alignment performance.

Experimental results

Research questions

  • RQ1Can a transformer-based model with multi-level cycle-consistency achieve superior non-contrast to contrast CT translation compared to existing GAN-based methods?
  • RQ2Does introducing multi-level cycle-consistency losses improve translation fidelity and reduce visual artifacts in medical image translation?
  • RQ3Can CyTran effectively reduce Hounsfield unit (HU) discrepancies between contrast and non-contrast CT scans to enhance downstream image registration?
  • RQ4Is the proposed hybrid CNN-transformer architecture capable of generating full-resolution, high-fidelity CT scans without mode collapse or structural artifacts?
  • RQ5To what extent does integrating CyTran into a registration pipeline improve alignment accuracy compared to standard registration methods?

Key findings

  • CyTran significantly outperforms state-of-the-art methods including pix2pix, U-GAT-IT, CycleGAN, CWT-GAN, and AttentionGAN in both image translation and registration tasks.
  • The multi-level cycle-consistency (MLCC) loss leads to superior registration performance compared to standard cycle-consistency, confirming its effectiveness in preserving structural consistency across feature levels.
  • Human evaluations confirm that CyTran is the only method that does not introduce visual artifacts during translation, a critical advantage in clinical applications.
  • The recursive cascaded ViT-V-Net with CyTran achieves the highest registration performance, with optimal gains at 3 cascades for arterial→native and 2 cascades for venous→native translation.
  • CyTran improves the performance of a state-of-the-art image registration method by reducing HU-level differences, enabling more accurate alignment of contrast and non-contrast CT scans.
  • The release of the Coltea-Lung-CT-100W dataset, comprising 100 triphasic 3D lung CT scans (37,290 images), provides a valuable benchmark for future research in medical image translation and registration.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.