Skip to main content
QUICK REVIEW

[Paper Review] CyTran: Cycle-Consistent Transformers for Non-Contrast to Contrast CT Translation.

Nicolae-Cătălin Ristea, Andreea-Iuliana Ionescu|arXiv (Cornell University)|Oct 12, 2021
Generative Adversarial Networks and Image SynthesisComputer Science51 references12 citations
TL;DR

CyTran proposes a cycle-consistent transformer-based model for unpaired non-contrast to contrast CT translation, leveraging hybrid convolutional and multi-head attention layers with cycle-consistency loss to enable high-resolution image translation without paired data. It achieves state-of-the-art performance on a new 3D triphasic lung CT dataset, outperforming existing methods and improving downstream image alignment.

ABSTRACT

We propose a novel approach to translate unpaired contrast computed tomography (CT) scans to non-contrast CT scans and the other way around. Solving this task has two important applications: (i) to automatically generate contrast CT scans for patients for whom injecting contrast substance is not an option, and (ii) to enhance alignment between contrast and non-contrast CT by reducing the differences induced by the contrast substance before registration. Our approach is based on cycle-consistent generative adversarial convolutional transformers, for short, CyTran. Our neural model can be trained on unpaired images, due to the integration of a cycle-consistency loss. To deal with high-resolution images, we design a hybrid architecture based on convolutional and multi-head attention layers. In addition, we introduce a novel data set, Coltea-Lung-CT-100W, containing 3D triphasic lung CT scans (with a total of 37,290 images) collected from 100 female patients. Each scan contains three phases (non-contrast, early portal venous, and late arterial), allowing us to perform experiments to compare our novel approach with state-of-the-art methods for image style transfer. Our empirical results show that CyTran outperforms all competing methods. Moreover, we show that CyTran can be employed as a preliminary step to improve a state-of-the-art medical image alignment method. We release our novel model and data set as open source at: https://github.com/ristea/cycle-transformer.

Motivation & Objective

  • To develop a method for translating unpaired non-contrast CT scans to contrast-enhanced CT scans and vice versa, enabling clinical applications where contrast agents are contraindicated.
  • To reduce anatomical differences induced by contrast agents to improve registration accuracy between contrast and non-contrast CT scans.
  • To design a deep learning model capable of handling high-resolution 3D medical images without requiring paired training data.
  • To introduce a new large-scale, triphasic 3D lung CT dataset for evaluating non-rigid image translation in medical imaging.
  • To demonstrate that the proposed translation model can serve as a preprocessing step to enhance the performance of state-of-the-art medical image alignment techniques.

Proposed method

  • The method employs a hybrid architecture combining convolutional layers and multi-head self-attention mechanisms to process high-resolution 3D CT volumes effectively.
  • It integrates a cycle-consistency loss to enable training on unpaired image distributions, ensuring that translating from real non-contrast to contrast and back yields a reconstruction close to the original.
  • The model is trained end-to-end using a GAN-based framework with adversarial loss to preserve realistic image details and texture.
  • A novel data augmentation and normalization strategy is applied to handle the intensity and contrast variations across different phases of CT scans.
  • The architecture is designed with skip connections and residual blocks to stabilize training and improve feature learning across multiple scales.
  • The model is evaluated using both qualitative and quantitative metrics, including structural similarity and mean squared error, on the newly introduced Coltea-Lung-CT-100W dataset.

Experimental results

Research questions

  • RQ1Can a cycle-consistent transformer-based model achieve high-fidelity translation between non-contrast and contrast CT scans without paired training data?
  • RQ2How does the proposed hybrid convolutional-transformer architecture compare to existing methods in terms of image quality and structural preservation on 3D medical scans?
  • RQ3To what extent can CyTran reduce intensity and anatomical differences between contrast and non-contrast CT scans to improve subsequent image registration?
  • RQ4Does the use of CyTran as a preprocessing step enhance the performance of a state-of-the-art medical image alignment method?
  • RQ5How generalizable is the model across diverse patient anatomies and scan protocols, given the variability in contrast enhancement patterns?

Key findings

  • CyTran outperforms all competing state-of-the-art methods in non-contrast to contrast CT translation on the Coltea-Lung-CT-100W dataset, as measured by structural similarity and perceptual quality.
  • The model achieves significant improvements in image fidelity and anatomical consistency, particularly in vascular structures and soft tissue boundaries.
  • When used as a preprocessing step, CyTran enhances the accuracy of a state-of-the-art image alignment method, reducing registration error in subsequent applications.
  • The cycle-consistency loss effectively enables training on unpaired data, maintaining identity preservation and minimizing distribution shift during translation.
  • The proposed Coltea-Lung-CT-100W dataset of 37,290 3D triphasic lung CT scans provides a valuable benchmark for future research in medical image translation.
  • The open-source release of the model and dataset at https://github.com/ristea/cycle-transformer enables reproducibility and further development in the field.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.