[Paper Review] DeepAAA: clinically applicable and generalizable detection of abdominal aortic aneurysm using deep learning
DeepAAA is a deep learning model based on a modified 3D U-Net with ellipse fitting that enables accurate, generalizable detection and quantification of abdominal aortic aneurysms (AAAs) in both contrast and non-contrast abdominal CT scans. It achieves 91% sensitivity and 95% specificity on training data and 85% sensitivity with 100% specificity on a diverse external validation set, outperforming reported radiologist performance on incidental AAA detection.
We propose a deep learning-based technique for detection and quantification of abdominal aortic aneurysms (AAAs). The condition, which leads to more than 10,000 deaths per year in the United States, is asymptomatic, often detected incidentally, and often missed by radiologists. Our model architecture is a modified 3D U-Net combined with ellipse fitting that performs aorta segmentation and AAA detection. The study uses 321 abdominal-pelvic CT examinations performed by Massachusetts General Hospital Department of Radiology for training and validation. The model is then further tested for generalizability on a separate set of 57 examinations with differing patient demographics and acquisition characteristics than the original dataset. DeepAAA achieves high performance on both sets of data (sensitivity/specificity 0.91/0.95 and 0.85 / 1.0 respectively), on contrast and non-contrast CT scans and works with image volumes with varying numbers of images. We find that DeepAAA exceeds literature-reported performance of radiologists on incidental AAA detection. It is expected that the model can serve as an effective background detector in routine CT examinations to prevent incidental AAAs from being missed.
Motivation & Objective
- To develop a clinically applicable deep learning model for automated detection and quantification of abdominal aortic aneurysms (AAAs) in routine abdominal CT exams.
- To address the high rate of missed incidental AAAs—reported at 35%—by improving detection sensitivity beyond current radiologist performance.
- To ensure robustness and generalizability across varying patient demographics, scan protocols, and imaging equipment, particularly for non-contrast CT scans.
- To provide a reliable 'second reader' tool that supports radiologists in early AAA detection and reduces inter-reader variability in diameter measurement.
- To demonstrate that deep learning can be effectively deployed in real-world clinical settings with minimal domain shift.
Proposed method
- A modified 3D U-Net architecture is used for 3D aortic segmentation on axial CT image volumes, enabling end-to-end learning from raw CT data.
- Post-segmentation, ellipse fitting is applied to the 3D aortic contours to estimate the maximal transverse diameter, which is used for AAA detection.
- The model is trained and validated on 321 abdominal-pelvic CT studies from Massachusetts General Hospital, including both contrast and non-contrast scans with varying slice thickness and number of images.
- A five-fold cross-validation strategy is employed on the primary dataset to ensure robust performance estimation, with Dice score and diameter deviation used as evaluation metrics.
- Generalizability is tested on a separate validation set of 57 studies acquired from different scanners and time periods, with distinct patient demographics and acquisition parameters.
- A 3.0 cm threshold is applied to the predicted maximal diameter to classify cases as AAA-positive or negative, aligning with clinical diagnostic criteria.
Experimental results
Research questions
- RQ1Can a deep learning model achieve high sensitivity and specificity in detecting incidental AAAs across both contrast and non-contrast abdominal CT scans?
- RQ2How well does the model generalize to external datasets with different imaging protocols, scanner types, and patient demographics?
- RQ3Does the model’s performance exceed that of radiologists in detecting incidental AAAs, particularly in non-contrast studies?
- RQ4Can the model reliably estimate the maximal aortic diameter with low bias and high precision across diverse image resolutions and slice thicknesses?
- RQ5To what extent does the model’s performance degrade when applied to data collected outside the original training distribution?
Key findings
- DeepAAA achieved a sensitivity of 0.91 and specificity of 0.95 on the primary training and validation dataset of 321 CT studies, with a mean Dice score of 0.873 ± 0.129.
- On the external validation set of 57 studies with different scanners, patient demographics, and acquisition protocols, the model achieved 85% sensitivity and 100% specificity, demonstrating strong generalizability.
- The model’s predicted maximal aortic diameter had a mean deviation of -1.7 mm (±8.7 mm) from the ground truth across cross-validation folds, indicating low bias and high precision.
- DeepAAA outperformed literature-reported radiologist sensitivity for incidental AAA detection, particularly in the 30–39 mm size range (0.68 vs. 0.52), while matching or exceeding performance in larger aneurysms.
- The model maintained high performance across non-contrast scans and varied image slice thicknesses (2–10 mm) and number of images (40–384), proving robustness to input variability.
- The model showed no significant overfitting to scanner-specific or cohort-specific features, as evidenced by consistent performance on the external validation set despite substantial domain shift.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.