[Paper Review] DeepCOVIDExplainer: Explainable COVID-19 Diagnosis Based on Chest X-ray Images
This paper introduces DeepCOVIDExplainer, an explainable neural ensemble for detecting COVID-19 from chest X-rays, using Grad-CAM++ and LRP to provide region-level explanations, achieving high precision/recall and a PPV around 96% for COVID-19 on balanced data.
Amid the coronavirus disease(COVID-19) pandemic, humanity experiences a rapid increase in infection numbers across the world. Challenge hospitals are faced with, in the fight against the virus, is the effective screening of incoming patients. One methodology is the assessment of chest radiography(CXR) images, which usually requires expert radiologist's knowledge. In this paper, we propose an explainable deep neural networks(DNN)-based method for automatic detection of COVID-19 symptoms from CXR images, which we call DeepCOVIDExplainer. We used 15,959 CXR images of 15,854 patients, covering normal, pneumonia, and COVID-19 cases. CXR images are first comprehensively preprocessed, before being augmented and classified with a neural ensemble method, followed by highlighting class-discriminating regions using gradient-guided class activation maps(Grad-CAM++) and layer-wise relevance propagation(LRP). Further, we provide human-interpretable explanations of the predictions. Evaluation results based on hold-out data show that our approach can identify COVID-19 confidently with a positive predictive value(PPV) of 91.6%, 92.45%, and 96.12%; precision, recall, and F1 score of 94.6%, 94.3%, and 94.6%, respectively for normal, pneumonia, and COVID-19 cases, respectively, making it comparable or improved results over recent approaches. We hope that our findings will be a useful contribution to the fight against COVID-19 and, in more general, towards an increasing acceptance and adoption of AI-assisted applications in the clinical practice.
Motivation & Objective
- Motivate rapid, interpretable screening of COVID-19 in clinical settings using chest X-rays (CXR).
- Develop an explainable DNN-based pipeline that discriminates normal, pneumonia, and COVID-19 CXR images.
- Combine multiple CNN architectures into an ensemble to improve robustness and generalization.
- Provide human-interpretable explanations by highlighting class-discriminating chest regions.
- Offer results and methods with reproducibility in mind (open-source code and data links).
Proposed method
- Image preprocessing including histogram equalization, edge enhancement, noise reduction, and artefact removal.
- Train several CNN architectures (VGG-16/19, ResNet-18/34, DenseNet-161/201) in a transfer-learning-inspired setting without ImageNet pretraining.
- Create snapshot models using cyclic cosine annealing and form an ensemble via Softmax class posterior averaging (SCPA) and prediction maximization (PM).
- Generate class-discriminating explanations using Grad-CAM++, Grad-CAM, and Layer-wise Relevance Propagation (LRP).
- Address class imbalance with class weights and evaluate with precision, recall, F1, and PPV across balanced and imbalanced datasets.
- Explain predictions with heatmaps and region localization to aid clinical trust and verification.
Experimental results
Research questions
- RQ1Can an explainable neural ensemble accurately distinguish COVID-19 from normal and non-COVID-19 pneumonia in CXR images?
- RQ2Do Grad-CAM++, Grad-CAM and LRP provide reliable, interpretable localization of decision-relevant chest regions for clinical use?
- RQ3Which CNN architectures and ensemble strategy yield the best performance under balanced and imbalanced class distributions?
- RQ4How does the proposed approach compare to existing COVID-19 CXR methods in terms of precision, recall and PPV?
- RQ5Is the model’s behavior sufficiently transparent to support AI-assisted clinical decision making?
Key findings
- DenseNet-161 and DenseNet-201 achieve top individual performance on balanced data, with DenseNet-161 reaching 0.952 precision, 0.945 recall, and 0.948 F1.
- On imbalanced data, DenseNet-161 and ResNet-18 show robust performance, with DenseNet-161 maintaining strong metrics.
- The ensemble using Softmax posterior averaging (SCPA) with VGG-19 + DenseNet-161 yields the best balanced results (Precision 0.946, Recall 0.943, F1 0.945).
- Prediction-maximization (PM) ensemble also performs well (0.937 Precision, 0.926 Recall, 0.931 F1 for the same architecture combo).
- COVID-19 positive predictions achieve a PPV of 96.12% on the balanced test set; COVIDx v1.0 comparison shows PPV of 96.74% under similar conditions, indicating competitive performance with state-of-the-art approaches.
- Class-wise metrics on the balanced dataset show Normal (Precision 0.942, Recall 0.927, F1 0.935), Pneumonia (Precision 0.916, Recall 0.928, F1 0.922), COVID-19 (Precision 0.904, Recall 0.905, F1 0.905).
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.