Skip to main content
QUICK REVIEW

[Paper Review] DeltaNet:Conditional Medical Report Generation for COVID-19 Diagnosis

Xian Wu, Shuxin Yang|arXiv (Cornell University)|Nov 12, 2022
Multimodal Machine Learning ApplicationsComputer Science17 citations
TL;DR

DeltaNet proposes a conditional medical report generation framework for COVID-19 diagnosis that retrieves similar historical reports and images, compares visual differences, and generates reports conditioned on these differences. It outperforms state-of-the-art methods on COVID-19, IU-Xray, and MIMIC-CXR datasets by leveraging conditional reports and feature subtraction to reduce visual and textual bias in medical image captioning.

ABSTRACT

Fast screening and diagnosis are critical in COVID-19 patient treatment. In addition to the gold standard RT-PCR, radiological imaging like X-ray and CT also works as an important means in patient screening and follow-up. However, due to the excessive number of patients, writing reports becomes a heavy burden for radiologists. To reduce the workload of radiologists, we propose DeltaNet to generate medical reports automatically. Different from typical image captioning approaches that generate reports with an encoder and a decoder, DeltaNet applies a conditional generation process. In particular, given a medical image, DeltaNet employs three steps to generate a report: 1) first retrieving related medical reports, i.e., the historical reports from the same or similar patients; 2) then comparing retrieved images and current image to find the differences; 3) finally generating a new report to accommodate identified differences based on the conditional report. We evaluate DeltaNet on a COVID-19 dataset, where DeltaNet outperforms state-of-the-art approaches. Besides COVID-19, the proposed DeltaNet can be applied to other diseases as well. We validate its generalization capabilities on the public IU-Xray and MIMIC-CXR datasets for chest-related diseases. Code is available at \url{https://github.com/LX-doctorAI1/DeltaNet}.

Motivation & Objective

  • To reduce radiologist workload in reporting large volumes of COVID-19 imaging studies.
  • To address visual and textual bias in medical report generation, where normal regions dominate and abnormal findings are underemphasized.
  • To develop a conditional generation framework that improves report accuracy by comparing current and historical medical images and reports.
  • To validate generalization of the method beyond COVID-19 to other chest-related diseases using public datasets.

Proposed method

  • DeltaNet retrieves conditional reports and images from patient history or via visual similarity for first-time patients.
  • It computes visual feature differences between the current and conditional images using feature subtraction and cross-attention mechanisms.
  • The model encodes the conditional report using a BiLSTM and fuses it with visual differences to condition the decoder.
  • The decoder generates reports step-by-step, conditioned on both the current image and the difference-aware representation from the conditional input.
  • The framework uses a three-stage process: retrieval, comparison, and conditional generation to highlight new findings.
  • It employs a visual encoder, conditional encoder, and decoder with cross-attention to align image and report features.

Experimental results

Research questions

  • RQ1Can a conditional generation framework reduce visual and textual bias in medical report generation?
  • RQ2Does retrieving and comparing historical reports improve report generation quality for new or follow-up imaging studies?
  • RQ3Can DeltaNet generalize to non-COVID-19 chest diseases using public datasets like IU-Xray and MIMIC-CXR?
  • RQ4How effective is conditional report input compared to conditional image input in improving generation performance?
  • RQ5Can feature subtraction and cross-attention better capture disease progression than direct feature concatenation?

Key findings

  • On the COVID-19 dataset, DeltaNet achieved BLEU-4 of 0.561, ROUGE-L of 0.635, and CIDEr of 0.588, outperforming all baselines.
  • On the IU-Xray dataset, DeltaNet achieved BLEU-3 of 0.224, BLEU-4 of 0.175, and ROUGE-L of 0.369, surpassing previous methods.
  • On the MIMIC-CXR dataset, DeltaNet achieved BLEU-3 of 0.144, BLEU-4 of 0.103, and ROUGE-L of 0.270, demonstrating strong generalization.
  • The conditional report from the same patient (Self) yielded BLEU-4 of 0.114, outperforming reports from other patients (Others) with BLEU-4 of 0.101.
  • The ablation study showed that using conditional reports (Rc) improved performance over conditional images (Ic), with BLEU-4 of 0.134 vs. 0.103 on IU-Xray.
  • Direct concatenation of Ic and Rc features underperformed DeltaNet’s subtraction and cross-attention mechanism, confirming the benefit of difference modeling.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.