This paper proposes a dual-purpose liquid neon scintillation detector for simultaneous detection of WIMP dark matter and pp solar neutrinos. Using Monte Carlo simulations and a maximum-likelihood event vertex fitter with PMT time resolution, it demonstrates that a 300 cm radius detector can achieve a 13 keV energy threshold, 1% pp neutrino flux uncertainty, and a spin-independent WIMP-nucleon cross-section sensitivity of ~10⁻⁴⁶ cm² for 100 GeV WIMPs with commercially available PMTs.
Detailed Monte-Carlo simulations were used to evaluate the performance of a liquid neon scintillation detector for dark matter and low-energy solar neutrino interactions. A maximum-likelihood event vertex fitter including PMT time information was developed, which significantly improves position resolution over spatial-only algorithms, and substantially decreases the required detector size and achievable analysis energy threshold. The ultimate sensitivity to WIMP dark matter and the pp flux uncertainty are evaluated as a function of detector size. The dependence on the neon scintillation and PMT properties are evaluated. A 300 cm radius detector would allow a ~13 keV threshold, a pp flux uncertainty of ~1%, and limits on the spin-independent WIMP-nucleon cross-section of ~10^{-46} cm^2 for a 100 GeV WIMP, using commercially available PMTs. Detector response calibration and background requirements for a precision pp measurement are defined. Internal radioactivity requirements for uranium, thorium, and krypton are specified, and it is shown that the PMT data could be used for an in-situ calibration of the troublesome krypton-85. A set of measurements of neon scintillation properties and PMT characteristics are outlined which will be needed in order to evaluate feasibility and fully optimize the design of a neon-based detector.
Motivation & Objective
- To design a dual-purpose liquid neon scintillation detector capable of detecting both WIMP dark matter and low-energy pp solar neutrinos.
- To evaluate the detector's sensitivity to WIMP-nucleon cross-sections and pp neutrino flux with high precision.
- To determine the design constraints, including required scintillation light yield, PMT performance, and background control, for achieving sub-percentage-level flux uncertainty.
- To establish calibration and background mitigation strategies, particularly for internal radioactivity and cosmogenic backgrounds.
- To identify critical material and detector parameters requiring experimental measurement to optimize detector performance and sensitivity.
Proposed method
- Utilized detailed GEANT4-based Monte Carlo simulations to model particle interactions, scintillation light production, and photon transport in liquid neon.
- Implemented a maximum-likelihood event vertex fitter that incorporates PMT time information to improve spatial resolution beyond spatial-only reconstruction.
- Modeled detector response using realistic PMT characteristics, including quantum efficiency, afterpulsing, and dark noise, with ultra-low background glass.
- Simulated scintillation light yield and quenching factors for electron and nuclear recoils, with emphasis on prompt-to-total light ratios for event discrimination.
- Quantified background contributions from external sources, internal radioactivity (U, Th, Kr), and cosmogenic events, applying reconstruction-based cuts.
- Evaluated detector performance across varying sizes and input parameters (e.g., light yield, Rayleigh scattering, quenching factor) to determine sensitivity dependencies.
Experimental results
Research questions
- RQ1What detector size and design are required to achieve a 13 keV energy threshold and 1% uncertainty in the pp neutrino flux?
- RQ2How does the inclusion of PMT time information in event reconstruction improve position resolution and reduce required detector size?
- RQ3What are the dominant background sources for a pp neutrino measurement in a liquid neon detector, and how can they be mitigated?
- RQ4How sensitive is the WIMP detection sensitivity to uncertainties in key detector parameters such as light yield, quenching factor, and Rayleigh scattering?
- RQ5What are the required purity levels for neon and PMT radioactivity to achieve the desired sensitivity for both WIMP and solar neutrino detection?
Key findings
- A 300 cm radius liquid neon detector can achieve a 13 keV energy threshold for WIMP detection using commercially available PMTs.
- The pp neutrino flux uncertainty can be reduced to approximately 1% with a 300 cm radius detector, enabling precision tests of solar neutrino models and mixing parameters.
- The spin-independent WIMP-nucleon cross-section sensitivity reaches ~10⁻⁴⁶ cm² for a 100 GeV WIMP, approaching the reach of next-generation direct detection experiments.
- The maximum-likelihood vertex fitter with PMT time information significantly improves position resolution, reducing the required detector size and lowering the energy threshold.
- WIMP sensitivity is most sensitive to the prompt-to-total light ratio for both electron and nuclear recoil events, while being relatively insensitive to absolute light yield and quenching factor uncertainties.
- Internal radioactivity from uranium, thorium, and krypton must be controlled to levels that allow a 300 m absorption length for 80 nm photons, with impurity limits derived from cross-section data.