Skip to main content
QUICK REVIEW

[Paper Review] Design of a High-Performance High-Pass Generalized Integrator Based Single-Phase PLL

Abhijit Kulkarni, Vinod John|arXiv (Cornell University)|Sep 14, 2016
Advancements in PLL and VCO TechnologiesEngineering27 references6 citations
TL;DR

This paper proposes a high-performance high-pass generalized integrator-based single-phase PLL (HGI-PLL) that eliminates dc offsets and mitigates harmonic distortion and frequency deviations. By modifying the second-order generalized integrator (SOGI) to include high-pass filtering, the HGI-PLL achieves fixed parameters, reduced implementation complexity, and the fastest transient response among SOGI-based PLLs, with unit vector THD kept below 1% under non-ideal grid conditions.

ABSTRACT

Grid-interactive power converters are normally synchronized to the grid using phase-locked loops (PLLs). The performance of the PLLs is affected by the non-ideal conditions in the sensed grid voltage such as harmonics, frequency deviations and dc offsets in single-phase systems. In this paper, a single-phase PLL is presented to mitigate the effects of these non-idealities. This PLL is based on the popular second order generalized integrator (SOGI) structure. The SOGI structure is modified to eliminate of the effects of input dc offsets. The resulting SOGI structure has a high-pass filtering property. Hence, this PLL is termed as high-pass generalized integrator based PLL (HGI-PLL). It has fixed parameters which reduces the implementation complexity and aids in the implementation in low-end digital controllers. The HGI-PLL is shown to have least resource utilization among the SOGI based PLLs with dc cancelling capability. Systematic design methods are evolved leading to the design that limits the unit vector THD to within 1% for given non-ideal input conditions in terms of frequency deviation and harmonic distortion. The proposed designs achieve the fastest transient response. The performance of this PLL has been verified experimentally. The results are found to agree with the theoretical prediction.

Motivation & Objective

  • Address the performance degradation of single-phase PLLs under non-ideal grid conditions, including dc offsets, harmonic distortion, and frequency deviations.
  • Overcome the limitations of conventional SOGI-PLLs, which suffer from dc injection and ripple errors due to input non-idealities.
  • Develop a fixed-parameter PLL design that ensures robust performance without requiring adaptive tuning, reducing implementation complexity.
  • Achieve the fastest transient response among SOGI-based PLLs while maintaining unit vector THD within 1% for specified grid disturbances.
  • Provide a systematic design methodology for bandwidth and gain selection to meet performance constraints under real-world grid conditions.

Proposed method

  • Modify the second-order generalized integrator (SOGI) structure to include a high-pass filtering characteristic, eliminating dc offset effects.
  • Implement a fixed-gain HGI block that provides a high-pass response, ensuring dc component rejection without requiring adaptive parameter adjustment.
  • Integrate the HGI output into a synchronous reference frame (SRF) PLL structure to estimate grid frequency and phase.
  • Use a PI controller in the SRF-PLL loop with design bandwidth $ f_{bw} $ to regulate the estimated frequency and phase.
  • Derive analytical expressions for unit vector THD based on harmonic sequence components (positive and negative) and their interaction with the PLL dynamics.
  • Establish a design framework using $ k $ (HGI gain) and $ f_{bw} $ to ensure $ u_{thd} \leq 1\% $ for given frequency deviation ($ \Delta f = \pm 8\% $) and harmonic distortion levels.

Experimental results

Research questions

  • RQ1How can a single-phase PLL be designed to maintain low unit vector THD under grid disturbances such as harmonic distortion and frequency deviation?
  • RQ2What modifications to the SOGI structure are required to eliminate dc offset effects without increasing implementation complexity?
  • RQ3Can a fixed-parameter PLL design achieve faster transient response than adaptive or conventional SOGI-based PLLs?
  • RQ4What is the optimal value of the HGI gain $ k $ that minimizes settling time while keeping THD within 1%?
  • RQ5How can a systematic design method be derived to guarantee performance under specified non-ideal grid conditions?

Key findings

  • The HGI-PLL achieves the fastest transient response among SOGI-based PLLs with dc cancellation capability, with worst-case settling time $ t_{sd} = t_{s,srf} + t_{s,hgi} $.
  • The proposed design limits unit vector THD to within 1% for frequency deviations up to ±8% and specified harmonic distortions, as per the design constraints.
  • The HGI-PLL uses fixed parameters, reducing implementation complexity and enabling deployment on low-end digital controllers.
  • The optimal HGI gain $ k_{opt,h} $ is derived analytically to minimize settling time while satisfying the THD performance bound.
  • The set $ \mathbf{K_u} $ of HGI gains $ k $ that ensure $ u_{thd} \leq 1\% $ is determined for any given $ f_{bw} $, enabling systematic design.
  • Experimental results confirm the theoretical predictions, showing excellent agreement between simulation and real-world performance.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint