[Paper Review] Design, scale-up and characterization of the data acquisition system for the ANAIS dark matter experiment
This paper presents the design, scale-up, and characterization of a high-performance data acquisition (DAQ) system for the ANAIS dark matter experiment, employing photomultiplier tubes (PMTs) and custom VME-based electronics to achieve low-energy threshold, low background, and high stability. The system enables precise coincidence triggering and real-time monitoring, with successful testing on three detectors and demonstrated scalability for future deployment with 37 detectors.
The ANAIS project has been a long time effort devoted to carry out an experiment to detect dark matter annual modulation with very low background NaI(Tl) detectors. It is expected to be fully commissioned along 2016. This experiment could confirm the DAMA/LIBRA positive signal with the same target and technique. This work was devoted to the design, implementation and characterization of a data acquisition system suitable for the ANAIS experiment, having in mind the ANAIS requirements: very low energy threshold, a background as low as possible in the region of interest, a high enough exposure and a rigorous parameter control in order to monitor systematics. This work describes the Photomultiplier Tubes used by the ANAIS modules and the algorithms and protocol developed in order to pass quality tests to all units. It presents the design and implementation of the electronic front-end for the ANAIS modules and muon tagging system along with the data acquisition software. The analysis software was adapted from the software of the previous prototypes to allow easy scale-up for the full experiment. Finally, the test of the optical performance of the Alpha Spectra modules and the tests of data acquisition and monitoring of environmental parameters are presented.
Motivation & Objective
- To develop a scalable, stable, and low-background data acquisition system for the ANAIS dark matter experiment targeting WIMP detection via annual modulation.
- To achieve a low energy threshold and high signal-to-noise ratio through optimized photomultiplier response and electronic front-end design.
- To ensure long-term operational stability through real-time monitoring of environmental parameters and hardware performance.
- To enable precise coincidence triggering with a 100 ns window, critical for detecting low-energy WIMP signals.
- To validate the system's performance through characterization on three detectors and prepare for full-scale deployment with 37 detectors.
Proposed method
- Employed Hamamatsu R12669SEL2 PMTs with customized voltage dividers and high-voltage power supplies to optimize single-electron response and quantum efficiency.
- Designed a VME-based digital and analog front-end using NIM modules, time scalers, and MATACQ modules for high dynamic range and high sampling rate signal acquisition.
- Implemented a coincidence trigger system with a 100 ns window, validated through pulse shape analysis and real-time clock synchronization.
- Developed a modular DAQ software stack with standardized file naming, run logging, and automated data processing for real-time analysis.
- Integrated slow control systems to monitor temperature, radon concentration, pressure, nitrogen flux, and PMT power supply stability.
- Conducted extensive characterization of preamplifiers, baseline stability, trigger efficiency, and noise reduction using deconvolution and peak-to-valley ratio analysis.
Experimental results
Research questions
- RQ1How can a scalable and stable DAQ system be designed to meet the stringent requirements of low-energy WIMP detection in the ANAIS experiment?
- RQ2What is the optimal configuration of PMT voltage divider and high-voltage supply to maximize signal fidelity and minimize dark counts?
- RQ3How does environmental variation, particularly temperature, affect the coincidence window timing and what mitigation strategies are effective?
- RQ4What level of dead time and live time accuracy can be achieved in a high-throughput, multi-channel DAQ system under real experimental conditions?
- RQ5Can the DAQ system reliably support the transition from a 3-detector prototype to a 37-detector configuration with consistent performance and low background?
Key findings
- The DAQ system successfully demonstrated scalability and reliability on three ANAIS detectors, validating its design for future deployment with 37 detectors.
- A 100 ns coincidence window was confirmed as critical for low-energy signal detection, with temperature-induced timing drifts of up to 6 ns posing a risk to annual modulation sensitivity.
- Real-time monitoring of environmental parameters (temperature, radon, pressure, nitrogen flux) showed stable performance, enabling long-term data quality control.
- Baseline stability was improved through automated calibration and feedback, reducing baseline walk and enhancing energy resolution.
- The system achieved high trigger efficiency and low dead time, with live time measurements closely matching theoretical expectations.
- The characterization protocol for PMTs—including gain curves, dark counts, and relative quantum efficiency—was automated and proven effective for consistent detector selection.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.