Skip to main content
QUICK REVIEW

[Paper Review] Development and Application of an eV Neutron Polarization for Parity Violation Studies at CSNS Back-n Beamline

Xu Qin, Tianhao Wang|arXiv (Cornell University)|Feb 19, 2026
Atomic and Subatomic Physics ResearchPhysics and Astronomy0 citations
TL;DR

The paper reports the development of an in-situ eV neutron polarization system at CSNS Back-n for parity-violation studies and demonstrates PV measurement with a 7.78% asymmetry at a 0.747 eV La-139 resonance.

ABSTRACT

The dynamic enhancement of symmetry-breaking effects in neutron-nucleus resonances provides a sensitive testing ground for Time-Reversal Invariance Violation (TRIV). Exploiting this mechanism, the Neutron Optics Parity and Time Reversal Experiment (NOPTREX) seeks to elucidate the origin of the universe's baryon asymmetry. Critical to this effort is the precise measurement of Parity Violation (PV) asymmetries, which is essential to calibrate the nuclear parameters required for future TRIV experiments. To facilitate these studies, we developed an eV polarized neutron at the Back-n white neutron beamline of the China Spallation Neutron Source (CSNS). Neutron polarization is generated by an in-situ Spin-Exchange Optical Pumping (SEOP) $^3$He filter. Spin manipulation is performed by an adiabatic spin flipper, while spin polarization is preserved over the flight path by a vacuum transport system equipped with a solenoidal guide field. Experiments successfully measured an asymmetry of approximately $7.8 \pm 2.4$ (stat.) $\pm 0.3$ (sys.) % at the 0.747 eV p-wave resonance of $^{139}$La. These results are in agreement with previous results on this resonance and validate the system's capability for PV measurements.

Motivation & Objective

  • Motivate the search for Beyond the Standard Model CP violation via enhanced PV and TRIV in neutron-nucleus resonances.
  • Quantify and calibrate nuclear parameters for future TRIV experiments through precise PV measurements.
  • Demonstrate an in-situ polarized 3He-based neutron source and adiabatic spin-flipper system suitable for epithermal energies.
  • Utilize the Back-n beamline’s long flight path and unmoderated neutron spectrum to improve resonance resolution and measurement fidelity.

Proposed method

  • Create an in-situ 3He SEOP polarized neutron source achieving ~30% neutron polarization at 0.74 eV.
  • Implement an adiabatic spin flipper with a spatially rotating magnetic field to enable rapid spin reversal (~0.4 s) for drift suppression.
  • Transport polarized neutrons through a 6 m vacuum guide with a solenoidal field to preserve polarization along the flight path.
  • Measure PV asymmetries via neutron transmission at the 0.747 eV p-wave resonance in 139La, using the Back-n white neutron beamline’s ~76 m flight path to enhance TOF resolution.
  • Calibrate He-3 polarization with Neutron Spin Filter measurements and perform EPR-based saturation checks to ensure accurate polarization values.
Figure 1: Layout of the Back-n beam line at CSNS.
Figure 1: Layout of the Back-n beam line at CSNS.

Experimental results

Research questions

  • RQ1What PV asymmetries can be measured in eV neutron-nucleus resonances using an in-situ polarized neutron setup?
  • RQ2How accurately can PV-induced asymmetries be extracted at the 0.747 eV resonance in 139La with the Back-n beamline?
  • RQ3Can the CSNS Back-n system provide sufficient spectral clarity to separate p-wave resonances from s-wave background for PV studies?
  • RQ4What are the systematic effects of guide-field and spin-manipulation on PV measurements in this configuration?

Key findings

  • Measured PV asymmetry of 7.78% with statistical uncertainty 2.44% and systematic uncertainty 0.3% at the 0.747 eV 139La resonance.
  • Laminar calibration yields neutron polarization of 30.31% with 0.03% statistical uncertainty at the 0.734 eV 139La p-wave resonance.
  • Polarization system achieves ~30% neutron polarization at eV energies and demonstrates stable operation with adiabatic spin flipping.
  • Back-n’s extended 76 m flight path and unmoderated source provide sharper resonance profiles and improved TOF resolution for PV analyses.
  • Measurements validate the PV system’s capability and consistency with prior results for the same resonance.
Figure 2: Schematic of the high-energy polarized neutron system, showing the key components such as the in-situ $\hphantom{{}^{\text{3}}_{\text{}}}{\vphantom{\text{X}}}^{\mathchoice{\hbox to0.0pt{\hss$\displaystyle\vphantom{\smash[t]{\text{2}}}\text{3}$}}{\hbox to0.0pt{\hss$\textstyle\vphantom{\smas
Figure 2: Schematic of the high-energy polarized neutron system, showing the key components such as the in-situ $\hphantom{{}^{\text{3}}_{\text{}}}{\vphantom{\text{X}}}^{\mathchoice{\hbox to0.0pt{\hss$\displaystyle\vphantom{\smash[t]{\text{2}}}\text{3}$}}{\hbox to0.0pt{\hss$\textstyle\vphantom{\smas

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.