[Paper Review] Development of cryogenic low background detector based on enriched zinc molybdate crystal scintillators to search for neutrinoless double beta decay of $^{100}$Mo
This paper presents the development and characterization of cryogenic ZnMoO₄ scintillating bolometers enriched in ¹⁰⁰Mo for searching neutrinoless double beta decay. Using Monte Carlo simulations with GEANT4, the authors optimized light collection, modeled 2ν2β decay spectra, and evaluated background sources—including random coincidences and internal contamination—demonstrating effective rejection strategies for enhanced sensitivity in low-background environments at the Modane Underground Laboratory.
ZnMoO$_4$ scintillators with a mass of $\sim$ 0.3 kg, as well as Zn$^{100}$MoO$_4$ crystals enriched in the isotope $^{100}$Mo were produced for the first time by using the low-thermal-gradient Czochralski technique. The optical and luminescent properties of the produced crystals were studied to estimate the progress in crystal growth quality. The low-temperature tests with a 313 g ZnMoO$_4$ and two enriched Zn$^{100}$MoO$_4$ crystals were performed aboveground in the Centre de Sciences Nucléaires et de Sciences de la Matière. The low background measurements with a three ZnMoO$_4$ and two enriched detectors installed in the EDELWEISS set-up at the Laboratoire Souterrain de Modane were carried out. To optimize the light collection in ZnMoO$_4$ scintillating bolometers, we have simulated the collection of scintillation photons in a detector module for different geometries by Monte Carlo method using the GEANT4 package. Response to the 2$ν$2$β$ decay of $^{100}$Mo was simulated for the enriched Zn$^{100}$MoO$_4$ detectors of different shape and mass to understand the dependence of 2$ν$2$β$ decay spectra on crystal shape. We have simulated 48 Zn$^{100}$MoO$_4$ crystals with a size of Ø60 $ imes$ 40 mm installed in the EDELWEISS cryostat. The contribution to background from the internal radioactive contamination of the crystals, cosmogenic activation and radioactive contamination of the set-up were simulated. Taking into account poor time resolution of the low temperature bolometers, we also studied contribution to background at the Q$_{2β}$ energy of random coincidences of signals, in particular of 2$ν$2$β$ decay, which is one of the main sources of background in cryogenic bolometers. Methods of the randomly coinciding events rejection were developed and compared. We have also analyzed dependence of the rejection efficiency on a cryogenic detector performance.
Motivation & Objective
- To develop high-purity, enriched ¹⁰⁰Mo-doped ZnMoO₄ crystals for use in cryogenic bolometers.
- To characterize the optical and luminescent properties of ZnMoO₄ and enriched Zn¹⁰⁰MoO₄ crystals grown via the low-thermal-gradient Czochralski method.
- To optimize light collection efficiency in detector modules using GEANT4-based Monte Carlo simulations.
- To simulate and evaluate background contributions from internal contamination, cosmogenic activation, and random coincidences in cryogenic bolometers.
- To develop and compare methods for rejecting random coincidence events, a major background source at the Q-value of 2ν2β decay.
Proposed method
- Growth of 0.3 kg ZnMoO₄ and enriched Zn¹⁰⁰MoO₄ crystals using the low-thermal-gradient Czochralski technique.
- Measurement of optical and luminescent properties to assess crystal quality and scintillation efficiency.
- Monte Carlo simulations with the GEANT4 package to model scintillation photon collection for various detector geometries.
- Simulation of 2ν2β decay spectra for enriched Zn¹⁰⁰MoO₄ detectors of different shapes and masses to study spectral dependence.
- Modeling of background contributions from internal radioactivity, cosmogenic activation, and set-up contamination in the EDELWEISS setup.
- Analysis of random coincidence events at the Q₂β energy, with evaluation of rejection efficiency as a function of detector time resolution and performance.
Experimental results
Research questions
- RQ1How does crystal geometry affect light collection efficiency and signal response in ZnMoO₄ scintillating bolometers?
- RQ2What is the impact of crystal shape and mass on the simulated 2ν2β decay spectrum in enriched Zn¹⁰⁰MoO₄ detectors?
- RQ3What are the dominant background contributions in cryogenic ZnMoO₄ detectors, including internal contamination and cosmogenic activation?
- RQ4How do random coincidence events—particularly from 2ν2β decay—contribute to background at the Q₂β energy, and how can they be effectively rejected?
- RQ5What is the dependence of random coincidence rejection efficiency on the time resolution and performance of low-temperature bolometers?
Key findings
- The first 0.3 kg ZnMoO₄ and enriched Zn¹⁰⁰MoO₄ crystals were successfully grown using the low-thermal-gradient Czochralski method, with promising optical and luminescent properties.
- Monte Carlo simulations demonstrated that detector geometry significantly influences light collection efficiency, with optimized designs improving signal detection.
- Simulations showed that the 2ν2β decay spectrum in enriched Zn¹⁰⁰MoO₄ detectors is sensitive to crystal shape and mass, affecting energy resolution and background modeling.
- Internal radioactivity and cosmogenic activation were identified as key contributors to background, with contamination levels simulated for accurate background budgeting.
- Random coincidence events, especially from 2ν2β decay, were found to be a major background source at the Q₂β energy, and multiple rejection methods were evaluated for effectiveness.
- Rejection efficiency of random coincidences was shown to strongly depend on detector time resolution, with better performance enabling more effective background suppression.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.