[Paper Review] Development of High Granular Neutron Time-of-Flight Detector for the BM@N experiment
This paper presents the design and simulation of a high granular neutron time-of-flight detector (HGND) for the BM@N experiment at the NICA complex, using 2000 plastic scintillator cells with 100–150 ps time resolution and SiPM readout to enable precise neutron energy and flow measurements. The detector achieves ~50–60% reconstruction efficiency and 1–13% energy resolution across 300–4000 MeV, enabling high-precision study of neutron azimuthal flow to constrain the symmetry energy in dense nuclear matter.
The HGND (High Granular Neutron Detector) is developed for the BM@N (Baryonic Matter at Nuclotron) experiment on the extracted beam of the Nuclotron at JINR, Dubna. The HGND will be used to measure the azimuthal flow of neutrons produced with energies ranging from 300 to 4000 MeV in heavy-ion collisions at beam energies of 2--4 AGeV. The azimuthal flow of charged particles will be measured using the BM@N magnet spectrometer. The data on the azimuthal flow of neutrons will shed light on the study of the high-density Equation of State (EoS) of isospin-symmetric nuclear matter, which is crucial for studying astrophysical phenomena such as neutron stars and their mergers. The HGND has a highly granular structure with approximately 2000 plastic scintillation detectors (cells), each measuring 4$ imes$4$ imes$2.5 cm$^3$. These detectors are arranged in 16 layers, with 121 detectors in each layer, and are subdivided by copper absorber plates with a thickness of 3 cm. The light from each cell is detected with SiPM (Silicon Photomultiplier) with an active area of 6$ imes$6 mm$^2$. Developed multi-channel TDC board based on the Kintex FPGA chip with a bin width of 100 ps will be used to perform precise timestamp and amplitude measurement using Time-over-Threshold (ToT) method. Good spatial resolution due to the high granularity together with a cell's time resolution of 100-150 ps ensures neutron reconstruction with good energy resolution. The design of the detector as well as the results from test measurements and simulations have been presented.
Motivation & Objective
- To measure the azimuthal flow of neutrons in heavy-ion collisions at beam energies of 2–4 AGeV to probe the symmetry energy in dense nuclear matter.
- To develop a compact, high-granularity neutron detector capable of identifying and reconstructing neutrons with high time and energy resolution in a high-multiplicity environment.
- To enable precise measurement of neutron energy and flow in the 300–4000 MeV range, crucial for constraining the equation of state of isospin-symmetric nuclear matter.
- To support future studies of neutron star properties and dynamics of neutron star mergers through improved experimental constraints on the symmetry energy term.
Proposed method
- The HGND consists of 16 layers of 121 plastic scintillator cells (4×4×2.5 cm³) arranged in a 2000-cell array, with 3 cm copper absorber plates between layers to suppress background.
- Each cell is read out by a 6×6 mm² SiPM, enabling high dynamic range and fast signal processing.
- A custom multi-channel TDC board based on a Kintex FPGA chip provides 100 ps time binning for precise timestamp and amplitude measurement via the Time-over-Threshold (ToT) method.
- Neutron energy is reconstructed using the time of flight from the first fired cell, with simulations accounting for time walk and resolution effects.
- The detector's performance is evaluated using Monte Carlo simulations of primary neutrons with multiplicity = 1, assuming 150 ps time resolution and energy deposition thresholds of 3 MeV (1/2 MIP).
- Machine learning techniques and cluster-based cell firing analysis are being developed to improve primary neutron identification in events with multiple neutrons.
Experimental results
Research questions
- RQ1Can a high granular neutron time-of-flight detector achieve sufficient time and energy resolution to reconstruct neutron energy in the 300–4000 MeV range with high efficiency?
- RQ2How does the detector's time resolution (100–150 ps) affect neutron energy reconstruction accuracy and resolution across the energy spectrum?
- RQ3What is the achievable neutron detection efficiency and energy resolution for primary neutrons in realistic conditions with background and multiple neutron multiplicities?
- RQ4To what extent can the azimuthal flow of neutrons be measured with this detector to constrain the symmetry energy in dense nuclear matter?
- RQ5How does the inclusion of copper absorber plates impact background suppression and neutron identification in high-multiplicity events?
Key findings
- The HGND achieves a neutron energy resolution of approximately 1% at 300 MeV and up to 13% at 4 GeV, with a time resolution of 100 ps.
- The neutron reconstruction efficiency is estimated at 50–60% across the 300–4000 MeV energy range, based on simulations with multiplicity = 1.
- Simulations show that the reconstructed energy spectrum closely matches the primary neutron spectrum, validating the time-of-flight reconstruction method.
- The detector is expected to accumulate about 10⁹ primary neutrons per month at a beam rate of 5×10⁵ Hz, enabling high-precision flow measurements.
- The first fired cell time is sufficient for energy reconstruction, and the method is robust even with 150 ps timing resolution.
- Future work includes developing cluster-based and machine learning-based methods to improve identification of primary neutrons in events with multiple neutrons.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.