Skip to main content
QUICK REVIEW

[Paper Review] Development of the 50-Mev DTL for the Jaeri/Kek Joint Project

F. Naito, K. Yoshino|arXiv (Cornell University)|Aug 19, 2000
Particle accelerators and beam dynamicsEngineering4 citations
TL;DR

This paper presents the development and high-power testing of a 50-MeV Alvarez-type DTL for the JAERI/KEK joint project, utilizing periodic reverse (PR) copper electroforming for cavity walls and rf contactors for robust RF coupling. Key results include a measured unloaded Q-value of 46,200 in a 1.4 m model tank, a breakdown field of 41 MV/m for PR electroformed copper, and successful operation of a 1000 A pulsed power supply with 5×10⁻⁴ current stability.

ABSTRACT

An Alvaretz-type DTL, to accelerate the H- ion beam from 3 to 50 MeV, is being constructed as the injector for the JAERI/KEK Joint Project. The following components of the DTL have been developed: (1) a cylindrical tank, made by copper electroforming; (2) rf contactors; (3) a pulse-excited quadrupole magnet with a hollow coil made by copper electroforming; (4) a switching-regulator-type pulsed-power supply for the quadrupole magnet. High-power tests of the components have been conducted using a short-model tank. Moreover a breakdown experiment of the copper electrodes has been carried out in order to study the properties of several kinds of copper materials.

Motivation & Objective

  • To design and construct a 50-MeV DTL injector for the JAERI/KEK high-intensity proton accelerator facility.
  • To develop and test critical components including RF contactors, electroformed copper cavities, and pulsed quadrupole magnets.
  • To evaluate the vacuum and RF performance of PR electroformed copper surfaces under high-power conditions.
  • To ensure reliable operation of the DTL through high-power conditioning and component reliability testing.
  • To address challenges in component integration, particularly in input coupler durability and field uniformity.

Proposed method

  • Fabricated cylindrical DTL tanks using 0.5 mm thick PR electroformed copper on iron substrates, followed by electropolishing.
  • Designed and tested two types of RF contactors: one between end plates and tanks, and another between drift tube stems and tanks, using thin copper layers on stainless steel springs.
  • Developed a compact, hollow-coil quadrupole magnet using PR copper electroforming, with silicon steel pole pieces.
  • Engineered a 20 kHz switching-regulator pulsed-power supply using IGBTs, achieving 1000 A output with <0.05% current ripple.
  • Conducted high-power tests on a 1.4 m model tank with full DTL components, including input coupler, tuners, and drift tubes with quadrupole magnets.
  • Performed breakdown tests on various copper electrodes to compare first breakdown fields under high-voltage conditions.

Experimental results

Research questions

  • RQ1What is the RF and vacuum performance of PR electroformed copper surfaces in a large cavity structure?
  • RQ2How effective are the RF contactors in maintaining low RF loss and high vacuum integrity?
  • RQ3Can a pulsed-power supply with high current stability (≤10⁻³) and fast rise time (5 ms) reliably drive the quadrupole magnet in the drift tube?
  • RQ4What is the first breakdown field strength of PR electroformed copper compared to other copper processing methods?
  • RQ5How does the field non-uniformity in the DTL affect performance, and can it be mitigated through design adjustments?

Key findings

  • The unloaded Q-value of the 1.4 m model tank reached 46,200, or 93% of the estimated value, confirming high-quality RF performance.
  • The first breakdown field for PR electroformed copper was 41 MV/m, significantly higher than other copper types except diamond-burnished OFC.
  • The pulsed-power supply achieved a current stability of 5×10⁻⁴, meeting the requirement of <10⁻³ for flat-top current regulation.
  • Vacuum levels reached 10⁻⁵ Pa after 100 hours of evacuation, with an outgassing rate of 5.2×10⁻⁸ Pa·m³/s/m², comparable to OFC.
  • No surface discharges were observed after high-power conditioning, even after a ceramic window failure, indicating excellent surface integrity of the electroformed copper.
  • High-power conditioning achieved full power (160 kW input) in just two days using short pulses, demonstrating effective field conditioning.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.