Skip to main content
QUICK REVIEW

[Paper Review] Development of the Photomultiplier-Tube Readout System for the CTA Large Size Telescope

H. Kubo, R. Paoletti|arXiv (Cornell University)|Jul 12, 2013
Radiation Detection and Scintillator TechnologiesPhysics and Astronomy4 citations
TL;DR

This paper presents the Dragon prototype, a high-speed, low-power photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array's Large Size Telescope (LST), using the DRS4 analog memory ASIC to sample PMT signals at 2 GHz with 4,096 sampling points per channel. The system successfully digitized single photoelectron pulses and achieved a signal-to-noise ratio of 3.6, demonstrating feasibility for high dynamic range, compact, and cost-effective VHE gamma-ray detection.

ABSTRACT

We have developed a prototype of the photomultiplier tube (PMT) readout system for the Cherenkov Telescope Array (CTA) Large Size Telescope (LST). Two thousand PMTs along with their readout systems are arranged on the focal plane of each telescope, with one readout system per 7-PMT cluster. The Cherenkov light pulses generated by the air showers are detected by the PMTs and amplified in a compact, low noise and wide dynamic range gain block. The output of this block is then digitized at a sampling rate of the order of GHz using the Domino Ring Sampler DRS4, an analog memory ASIC developed at Paul Scherrer Institute. The sampler has 1,024 capacitors per channel and four channels are cascaded for increased depth. After a trigger is generated in the system, the charges stored in the capacitors are digitized by an external slow sampling ADC and then transmitted via Gigabit Ethernet. An onboard FPGA controls the DRS4, trigger threshold, and Ethernet transfer. In addition, the control and monitoring of the Cockcroft-Walton circuit that provides high voltage for the 7-PMT cluster are performed by the same FPGA. A prototype named Dragon has been developed that has successfully sampled PMT signals at a rate of 2 GHz, and generated single photoelectron spectra.

Motivation & Objective

  • To design a compact, low-power, and cost-effective PMT readout system for the CTA Large Size Telescope (LST), which requires thousands of PMT channels with high timing resolution.
  • To address the challenge of high night sky background (NSB) in VHE gamma-ray detection by enabling fast, high-bandwidth digitization of short Cherenkov light pulses (3–4 ns FWHM).
  • To achieve wide dynamic range (>1000 p.e.) and single photoelectron resolution to improve energy threshold and sensitivity in gamma-ray astronomy.
  • To develop a scalable, modular readout architecture with one system per 7-PMT cluster, enabling mass production and integration into the full LST camera system.

Proposed method

  • Utilizes the DRS4 analog memory ASIC, which samples signals at up to 5 GS/s with 1,024 capacitors per channel, cascaded across four channels to achieve 4,096 sampling points (4 µs depth) at 1 GS/s.
  • Employs a preamplifier (Mini-circuits LEE-39+) to condition PMT signals before digitization, with separate high- and low-gain channels to extend dynamic range.
  • Integrates an FPGA for real-time control of DRS4 sampling, trigger thresholding, data buffering in SRAM, and Gigabit Ethernet transmission via SiTCP protocol.
  • Incorporates a Cockcroft-Walton high-voltage supply for the 7-PMT cluster, with FPGA-based monitoring and control for stability and reliability.
  • Uses a slow-sampling ADC (≈30 MHz) to digitize the stored charge in the DRS4 capacitors after a trigger is issued, enabling full waveform reconstruction.
  • Employs a UV laser and LED for calibration, allowing measurement of single photoelectron spectra and signal-to-noise ratio.

Experimental results

Research questions

  • RQ1Can the DRS4 ASIC achieve sufficient sampling speed (≥2 GHz) and depth (≥4,096 points) to accurately reconstruct sub-nanosecond PMT pulses from Cherenkov showers?
  • RQ2Does the system achieve a dynamic range exceeding 1000 photoelectrons while maintaining single photoelectron resolution and low noise?
  • RQ3Can the FPGA-based control system efficiently manage high-speed data acquisition, trigger generation, and Gigabit Ethernet transmission with minimal dead time?
  • RQ4What is the signal-to-noise ratio of the single photoelectron peak in the digitized PMT signal, and does it meet the requirements for VHE gamma-ray detection?
  • RQ5Is the system scalable and suitable for mass production in a full LST camera with 2,000 PMTs and 286 PMT clusters?

Key findings

  • The Dragon prototype successfully sampled PMT signals at 2 GS/s with a sampling depth of 4,096 points, enabling full reconstruction of 3–4 ns FWHM Cherenkov pulses.
  • The high-gain channel achieved a dynamic range of 60 p.e. and a noise level of 0.1 p.e. (rms), while the low-gain channel reached 2,500 p.e., satisfying the >1,000 p.e. requirement.
  • The system achieved a signal-to-noise ratio of 3.6 for the single photoelectron peak, measured as (mean of single p.e. pulse - pedestal mean) / pedestal RMS.
  • The measured bandwidths were 260 MHz (high gain) and 190 MHz (low gain), with the DRS4 readout board preserving the preamplifier’s bandwidth characteristics.
  • The readout dead time was 0.9% at 1 kHz and 5.4% at 7 kHz, indicating low latency and high efficiency for continuous data acquisition.
  • A clear single photoelectron peak was observed in the spectrum, confirming the system’s capability to resolve individual photoelectrons at a gain of 5×10⁴.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.