Skip to main content
QUICK REVIEW

[Paper Review] Direct Estimation of Regional Wall Thicknesses via Residual Recurrent Neural Network

Wufeng Xue, Ilanit Ben Nachum|arXiv (Cornell University)|May 26, 2017
Cardiac Imaging and DiagnosticsMedicine28 references15 citations
TL;DR

This paper proposes a novel Residual Recurrent Neural Network (ResRNN) for direct, end-to-end estimation of regional wall thicknesses (RWT) in cardiac MRI, leveraging both spatial and temporal dependencies through a dual-path architecture: a CNN for frame-wise embedding and a Circle-RNN for modeling dynamic myocardial deformation. The method achieves a mean absolute error of 1.44 mm across 145 subjects, outperforming state-of-the-art segmentation-based and two-phase direct methods.

ABSTRACT

Accurate estimation of regional wall thicknesses (RWT) of left ventricular (LV) myocardium from cardiac MR sequences is of significant importance for identification and diagnosis of cardiac disease. Existing RWT estimation still relies on segmentation of LV myocardium, which requires strong prior information and user interaction. No work has been devoted into direct estimation of RWT from cardiac MR images due to the diverse shapes and structures for various subjects and cardiac diseases, as well as the complex regional deformation of LV myocardium during the systole and diastole phases of the cardiac cycle. In this paper, we present a newly proposed Residual Recurrent Neural Network (ResRNN) that fully leverages the spatial and temporal dynamics of LV myocardium to achieve accurate frame-wise RWT estimation. Our ResRNN comprises two paths: 1) a feed forward convolution neural network (CNN) for effective and robust CNN embedding learning of various cardiac images and preliminary estimation of RWT from each frame itself independently, and 2) a recurrent neural network (RNN) for further improving the estimation by modeling spatial and temporal dynamics of LV myocardium. For the RNN path, we design for cardiac sequences a Circle-RNN to eliminate the effect of null hidden input for the first time-step. Our ResRNN is capable of obtaining accurate estimation of cardiac RWT with Mean Absolute Error of 1.44mm (less than 1-pixel error) when validated on cardiac MR sequences of 145 subjects, evidencing its great potential in clinical cardiac function assessment.

Motivation & Objective

  • To address the lack of direct RWT estimation methods in cardiac MRI, which traditionally rely on time-consuming segmentation.
  • To overcome challenges posed by diverse cardiac anatomy and complex regional myocardial deformation across the cardiac cycle.
  • To develop an end-to-end deep learning framework that captures both spatial and temporal dependencies in cardiac sequences.
  • To eliminate reliance on manual segmentation and improve accuracy and robustness in RWT estimation.
  • To introduce a novel Circle-RNN that models periodic cardiac dynamics and circular spatial layout, reducing first-step initialization bias.

Proposed method

  • The ResRNN employs a dual-path architecture: a CNN path for independent frame-wise RWT estimation using image embeddings, and an RNN path for residual refinement.
  • The RNN path uses a temporal RNN to model long-range dependencies across cardiac phases and a spatial RNN to capture mutual relationships among adjacent myocardial segments.
  • A novel Circle-RNN is designed to mitigate the impact of null initial hidden states by exploiting the periodic nature of cardiac cycles and the circular arrangement of LV wall segments.
  • The network is trained end-to-end using a residual learning strategy, where the RNN learns to correct errors from the CNN's initial predictions.
  • The method processes short-axis cine MRI sequences, with RWT estimated per segment using a standardized 6-segment model.
  • The framework is validated using 5-fold cross-validation on a dataset of 145 cardiac MRI subjects.

Experimental results

Research questions

  • RQ1Can a deep learning model directly estimate regional wall thicknesses from cardiac MRI without requiring prior segmentation?
  • RQ2How can spatial and temporal dependencies in cardiac motion be effectively modeled to improve RWT estimation accuracy?
  • RQ3Can a novel Circle-RNN architecture reduce the error introduced by null initial hidden states in the first cardiac frame?
  • RQ4Does end-to-end learning of spatial and temporal dynamics outperform two-phase methods that separate feature extraction and regression?
  • RQ5How does the proposed ResRNN compare to state-of-the-art segmentation-based and direct estimation methods in terms of RWT accuracy?

Key findings

  • The proposed ResRNN achieves a mean absolute error (MAE) of 1.44 mm across all 145 subjects, equivalent to less than one pixel, demonstrating high estimation accuracy.
  • The ResRNN outperforms the Max Flow segmentation-based method by 55.14% in MAE reduction, despite Max Flow achieving a high Dice score of 0.9182 for LV segmentation.
  • The ResRNN reduces error by 12.73% compared to the best two-phase direct method (MCDBN+RF), confirming the advantage of end-to-end learning.
  • The Circle-RNN consistently improves performance over the plain RNN, especially in early cardiac phases, by better preserving dynamic information from the first frame.
  • The ResRNN maintains consistently low estimation error across all cardiac frames, unlike Max Flow, which shows increasing error with distance from the first frame.
  • The dual-path design—combining CNN-based frame-wise estimation with RNN-based residual refinement—proves effective, as both components contribute uniquely to the final accuracy.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.