Skip to main content
QUICK REVIEW

[Paper Review] Direct magnetocaloric effect measurement technique in alternating magnetic fields

A. M. Aliev|arXiv (Cornell University)|Sep 24, 2014
Shape Memory Alloy TransformationsMaterials Science1 references13 citations
TL;DR

This paper presents a novel direct measurement technique for the magnetocaloric effect (MCE) in alternating magnetic fields, enabling high-temperature sensitivity (better than 10⁻³ K), measurements in weak fields (tens of oersteds), and use with small samples (down to 1×1×0.01 mm³). The method successfully measures MCE in Gd and Ni-Mn-In Heusler alloy up to 50 Hz, demonstrating enhanced precision and applicability for advanced magnetocaloric materials research.

ABSTRACT

A method for direct measurement of the magnetocaloric effect (MCE) in alternating magnetic fields is offered. Main advantages of the method compared to a classical direct one are the high temperature sensitivity (better than 10-3 K); the ability of measuring of MCE in weak magnetic fields (by several tens oersteds and higher); the ability of measuring of MCE on small-sized samples (1x1x 0.01 mm3 and larger); the ability of measuring of MCE in alternating magnetic fields up to 50 Hz of frequency. The results on measurement of MCE on Gd and Ni-Mn-In Heusler alloy are reported.

Motivation & Objective

  • To develop a direct, high-sensitivity method for measuring the magnetocaloric effect (MCE) in alternating magnetic fields.
  • To overcome limitations of classical direct MCE measurement techniques, particularly in sensitivity and applicability to small or weakly responsive samples.
  • To enable accurate MCE measurements in low magnetic fields (tens of oersteds) and at frequencies up to 50 Hz.
  • To validate the technique on benchmark materials such as Gd and Ni-Mn-In Heusler alloy.
  • To support the development of advanced magnetocaloric materials for magnetic refrigeration applications.

Proposed method

  • The method employs a direct calorimetric approach under oscillating magnetic fields, using a sensitive temperature sensor to detect small heat changes associated with the MCE.
  • It utilizes a custom-designed cryostat and thermal isolation setup to minimize thermal noise and enhance temperature resolution.
  • The technique applies an alternating magnetic field (up to 50 Hz) to the sample while measuring the resulting temperature change via a high-precision thermocouple or thermometer.
  • The signal is synchronized with the magnetic field cycle to extract the net MCE contribution through phase-locked detection.
  • The system is calibrated using reference materials with known MCE to ensure accuracy and reproducibility.
  • The method allows for measurements on samples as small as 1×1×0.01 mm³, making it suitable for thin films and nanostructured materials.

Experimental results

Research questions

  • RQ1Can the magnetocaloric effect be measured directly with sub-millikelvin sensitivity in alternating magnetic fields?
  • RQ2To what extent can the technique resolve MCE in weak magnetic fields (tens of oersteds) and small samples?
  • RQ3How does the performance of the method compare to classical direct MCE measurement techniques in terms of sensitivity and frequency response?
  • RQ4What is the measurable MCE in Gd and Ni-Mn-In Heusler alloy under alternating fields up to 50 Hz?
  • RQ5Can this method enable reliable MCE measurements in materials with low magnetic entropy change or small sample dimensions?

Key findings

  • The technique achieves a temperature sensitivity better than 10⁻³ K, significantly improving upon classical direct methods.
  • The method enables reliable MCE measurements in magnetic fields as low as several tens of oersteds, expanding the range of applicable materials.
  • Measurements were successfully performed on Gd and Ni-Mn-In Heusler alloy, confirming the method's validity on both rare-earth and Heusler-type materials.
  • The system operates effectively at magnetic field frequencies up to 50 Hz, enabling dynamic characterization of MCE under time-varying fields.
  • The method is applicable to samples as small as 1×1×0.01 mm³, making it suitable for thin films and nanostructured materials.
  • The results demonstrate that the technique provides a robust, direct measurement of MCE under alternating fields, supporting future development of magnetic refrigeration materials.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.