Skip to main content
QUICK REVIEW

[Paper Review] Disentangling Human Error from the Ground Truth in Segmentation of Medical Images

Le Zhang, Ryutaro Tanno|arXiv (Cornell University)|Jul 31, 2020
Advanced Neural Network ApplicationsComputer Science45 references76 citations
TL;DR

The paper presents an end-to-end CNN framework that jointly learns true segmentation labels and per-annotator pixel-wise confusion matrices from noisy multiclass medical image labels, improving segmentation accuracy especially when annotations are scarce or highly discordant.

ABSTRACT

Recent years have seen increasing use of supervised learning methods for segmentation tasks. However, the predictive performance of these algorithms depends on the quality of labels. This problem is particularly pertinent in the medical image domain, where both the annotation cost and inter-observer variability are high. In a typical label acquisition process, different human experts provide their estimates of the "true" segmentation labels under the influence of their own biases and competence levels. Treating these noisy labels blindly as the ground truth limits the performance that automatic segmentation algorithms can achieve. In this work, we present a method for jointly learning, from purely noisy observations alone, the reliability of individual annotators and the true segmentation label distributions, using two coupled CNNs. The separation of the two is achieved by encouraging the estimated annotators to be maximally unreliable while achieving high fidelity with the noisy training data. We first define a toy segmentation dataset based on MNIST and study the properties of the proposed algorithm. We then demonstrate the utility of the method on three public medical imaging segmentation datasets with simulated (when necessary) and real diverse annotations: 1) MSLSC (multiple-sclerosis lesions); 2) BraTS (brain tumours); 3) LIDC-IDRI (lung abnormalities). In all cases, our method outperforms competing methods and relevant baselines particularly in cases where the number of annotations is small and the amount of disagreement is large. The experiments also show strong ability to capture the complex spatial characteristics of annotators' mistakes.

Motivation & Objective

  • Motivate robust segmentation under high inter-observer variability in medical images.
  • Propose a two-network architecture to disentangle true labels from annotator behavior.
  • Enable learning from purely noisy annotations without ground-truth labels.

Proposed method

  • Two coupled CNNs: a segmentation network estimating p(y|x) and an annotator network estimating per-annotator pixel-wise confusion matrices A^{(r)}(x).
  • Predicted annotator distributions: p̂^{(r)}(x) = Â^{(r)}(x) · p̂θ(x).
  • Training optimizes the sum of cross-entropy losses between observed noisy labels and annotator predictions, plus a trace regularization term on Â^{(r)}(x) to encourage disentangling noise from true labels.
  • Loss: L_total = sum over images and annotators of CE(Â^{(r)}(x)·p̂θ(x), ỹ^{(r)}) + λ·tr(Â^{(r)}(x)).
  • Includes a warm-start where annotator CMs are initialized to be diagonally dominant (identity) to encourage sensible disentangling.
  • Optional low-rank (rank-1) CM approximations to reduce computation for many classes.

Experimental results

Research questions

  • RQ1Can a model learn the ground-truth segmentation distribution from exclusively noisy, multi-annotator labels?
  • RQ2Does jointly learning annotator behavior and true labels improve segmentation performance, especially with few annotations per image?
  • RQ3How well do image-dependent, pixel-wise confusion matrices capture annotator error patterns across diverse medical imaging datasets?
  • RQ4Does trace regularization enable unique recovery of the true class in challenging, sample-specific settings?
  • RQ5How does the proposed method compare to label-fusion baselines (STAPLE, Spatial STAPLE) and Probabilistic U-net across synthetic and real datasets?

Key findings

  • The proposed approach (Ours) achieves Dice of 82.92% on MNIST-based dense segmentation and 67.55% on MSLesion dense segmentation, outperforming STAPLE and Spatial STAPLE baselines.
  • CM estimation error (MSE) for annotators is substantially lower with Ours (e.g., 0.0893 for MNIST and 0.0811 for MSLesion) compared with baselines.
  • In single-label-per-image settings, Ours still outperforms baselines with Dice scores of 56.43% (MNIST/MS context shown in table), indicating robustness when annotations are scarce.
  • On BraTS and LIDC-IDRI, Ours yields higher Dice than STAPLE variants for both dense and single-label scenarios, and shows large improvements in CM estimation (e.g., 14.4% improvement on BraTS).
  • Generalised Energy Distance (GED) comparisons favour Ours over Probabilistic U-Net across MNIST, MS, BraTS, and LIDC-IDRI datasets (e.g., MNIST: 1.24 vs 1.46; MS: 1.67 vs 1.91; BraTS: 3.14 vs 3.23; LIDC-IDRI: 1.87 vs 1.97).
  • Across datasets, image-dependent pixel-wise CMs better capture inter-annotator variability than global CMs or per-image baselines, with consistent gains in segmentation accuracy and CM fidelity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.