Skip to main content
QUICK REVIEW

[Paper Review] Impact of individual rater style on deep learning uncertainty in medical imaging segmentation

Olivier Vincent, Charley Gros|arXiv (Cornell University)|May 5, 2021
Statistical Methods and InferenceMathematics25 references5 citations
TL;DR

This study investigates how individual rater style—specifically bias and consistency—affects deep learning uncertainty in medical image segmentation. Using two public MRI datasets (MS lesions and spinal cord grey matter), it shows that rater bias strongly correlates with model uncertainty (R² = 0.60 and 0.93), and that multi-center consensus labeling reduces uncertainty more effectively than single-center consensus due to center-specific rater styles.

ABSTRACT

While multiple studies have explored the relation between inter-rater variability and deep learning model uncertainty in medical segmentation tasks, little is known about the impact of individual rater style. This study quantifies rater style in the form of bias and consistency and explores their impacts when used to train deep learning models. Two multi-rater public datasets were used, consisting of brain multiple sclerosis lesion and spinal cord grey matter segmentation. On both datasets, results show a correlation ($R^2 = 0.60$ and $0.93$) between rater bias and deep learning uncertainty. The impact of label fusion between raters' annotations on this relationship is also explored, and we show that multi-center consensuses are more effective than single-center consensuses to reduce uncertainty, since rater style is mostly center-specific.

Motivation & Objective

  • To investigate the impact of individual rater style—specifically bias and consistency—on deep learning model uncertainty in medical image segmentation.
  • To quantify rater bias as the average deviation in lesion volume from consensus segmentation and rater consistency as the standard deviation of this deviation across images.
  • To evaluate how label fusion strategies (single-center vs. multi-center consensus) affect the relationship between rater style and model uncertainty.
  • To determine whether rater style metrics can inform model training or uncertainty reporting, potentially improving segmentation performance and reliability.

Proposed method

  • Defined rater bias as the mean absolute difference in positive voxel count between a rater’s segmentation and the consensus segmentation across all images.
  • Defined rater consistency as the standard deviation of the difference between a rater’s segmentation and the consensus, centered on the rater’s bias.
  • Used majority voting for consensus segmentation across raters to establish a ground-truth reference.
  • Trained deep learning models on annotations from individual raters and measured their uncertainty via prediction variance or entropy.
  • Compared absolute bias (volume-based) with relative bias (normalized by consensus volume) to assess sensitivity to lesion size.
  • Evaluated the impact of label fusion by comparing uncertainty when using single-center versus multi-center consensus as training targets.

Experimental results

Research questions

  • RQ1Does individual rater bias correlate with deep learning model uncertainty in medical image segmentation?
  • RQ2How does rater consistency influence model uncertainty, and is it a significant predictor?
  • RQ3Does the choice of label fusion strategy (single-center vs. multi-center consensus) affect the strength of the bias-uncertainty relationship?
  • RQ4Is relative bias (normalized by consensus volume) more effective than absolute bias in capturing rater style effects on uncertainty?
  • RQ5Can rater style metrics be used to improve model uncertainty estimation or guide data curation in medical segmentation tasks?

Key findings

  • A strong correlation was found between rater bias and deep learning model uncertainty, with R² = 0.60 for the MS lesion dataset and R² = 0.93 for the spinal cord grey matter dataset.
  • The relationship between bias and uncertainty remained significant when using relative bias (normalized by consensus volume), with R² = 0.64 for MS and R² = 0.93 for GM, indicating robustness to lesion size variation.
  • Multi-center consensus label fusion was more effective than single-center consensus in reducing model uncertainty, as rater style patterns were predominantly center-specific.
  • For the MS lesion dataset, relative bias highlighted an outlier rater more clearly than absolute bias, suggesting relative metrics improve sensitivity to small-lesion errors.
  • The spinal cord GM dataset showed lower overall bias and less variation between absolute and relative bias, likely due to higher inter-rater agreement and less lesion size variability.
  • The results suggest that rater style—particularly bias—can be leveraged as prior knowledge to refine model training or uncertainty estimation, potentially improving segmentation reliability.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.