Skip to main content
QUICK REVIEW

[Paper Review] Dry deposition model for a microscale aerosol dispersion solver based on the moment method

Viktor Ší́p, Luděk Beneš|arXiv (Cornell University)|May 11, 2016
Particle Dynamics in Fluid FlowsEngineering36 references9 citations
TL;DR

This paper develops a dry deposition model for microscale aerosol dispersion solvers using the moment method, integrating five deposition processes—Brownian diffusion, interception, impaction, turbulent impaction, and sedimentation—into a size-dependent deposition velocity formulation. The model, implemented in OpenFOAM, achieves ~8x computational speedup over the sectional method with 41 bins while maintaining particle size distribution accuracy (relative error <10% in the third moment), demonstrating viability for urban microscale air quality modeling.

ABSTRACT

A dry deposition model suitable for use in the moment method has been developed. Contributions from five main processes driving the deposition - Brownian diffusion, interception, impaction, turbulent impaction, and sedimentation - are included in the model. The deposition model was employed in the moment method solver implemented in the OpenFOAM framework. Applicability of the developed expression and the moment method solver was tested on two example problems of particle dispersion in the presence of a vegetation on small scales: a flow through a tree patch in 2D and a flow through a hedgerow in 3D. Comparison with the sectional method showed that the moment method using the developed deposition model is able to reproduce the shape of the particle size distribution well. The relative difference in terms of the third moment of the distribution was below 10\\% in both tested cases, and decreased away from the vegetation. Main source of this difference is a known overprediction of the impaction efficiency. When tested on the 3D test case, the moment method achieved approximately eightfold acceleration compared to the sectional method using 41 bins.

Motivation & Objective

  • To develop a dry deposition model compatible with the moment method for microscale aerosol dispersion simulations.
  • To include all five major dry deposition processes—Brownian diffusion, interception, impaction, turbulent impaction, and sedimentation—in a moment-method framework.
  • To test the model's accuracy and computational efficiency against the sectional method in 2D and 3D urban vegetation scenarios.
  • To enable efficient simulation of particle size distribution evolution in urban microscale environments with vegetation.

Proposed method

  • Adapted the Petroff et al. (2008b) dry deposition model for use in the moment method by expressing deposition velocity as a power-law function of particle diameter.
  • Formulated the moment method using three coupled PDEs for the first three moments (M₀, M₁, M₂) to represent the particle size distribution.
  • Implemented the model in a finite volume CFD solver using the OpenFOAM framework for 2D and 3D microscale flow and dispersion simulations.
  • Used a lognormal distribution assumption for the particle size distribution, enabling analytical moment computation.
  • Calculated deposition velocity as a sum of contributions from five physical processes, each expressed as a power-law in particle diameter.
  • Validated results against the sectional method using 41 size bins, comparing particle number and volume distributions.

Experimental results

Research questions

  • RQ1Can a dry deposition model incorporating five key deposition mechanisms be successfully formulated within the moment method framework for microscale aerosol dispersion?
  • RQ2How accurately does the moment method with the proposed deposition model reproduce particle size distribution shapes compared to the sectional method?
  • RQ3What is the computational performance gain of the moment method over the sectional method when simulating microscale particle dispersion in vegetated urban environments?
  • RQ4How does the overprediction of impaction efficiency affect the accuracy of the moment method relative to the sectional method?
  • RQ5To what extent can the moment method maintain accuracy while reducing computational cost in microscale urban air quality modeling?

Key findings

  • The moment method with the developed deposition model reproduced the shape of the particle size distribution with less than 10% relative difference in the third moment compared to the sectional method.
  • The primary source of discrepancy was the overprediction of impaction efficiency in the moment method, which led to higher deposition rates.
  • The 3D simulation showed that the relative error in the third moment decreased with distance from the vegetation, indicating improved accuracy in well-mixed regions.
  • The moment method achieved approximately eightfold computational speedup over the sectional method using 41 bins, with a runtime of 1128 seconds versus 9120 seconds.
  • A computational workload equivalent to the moment method could be achieved with only 5 bins in the sectional model, but this number is insufficient to accurately resolve the distribution.
  • The method is viable for microscale urban dispersion modeling when the particle size distribution is approximated as lognormal, and can be extended to multimodal distributions via superposition.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.