[Paper Review] Effect of pressure and temperature corrections on muon flux variability at ground level and underground
This study evaluates pressure and temperature corrections on muon flux variability at ground level and underground in Belgrade using integral methods and GFS atmospheric models. It demonstrates that combined corrections significantly reduce atmospheric-induced noise, enhancing sensitivity to non-atmospheric cosmic ray variations, with improved correlation to neutron monitor data after correction.
In Low Background Laboratory at Institute of Physics Belgrade, plastic scintillators are used to continuously monitor flux of the muon component of secondary cosmic rays. Measurements are performed on the surface as well as underground (25 m.w.e depth). Temperature effect on muon component of secondary cosmic rays is well known and several methods to correct for it are already developed and widely used. Here, we apply integral method to calculate correction coefficients and use GFS (Global Forecast System) model to obtain atmospheric temperature profiles. Atmospheric corrections reduce variance of muon flux and lead to improved sensitivity to transient cosmic ray variations. Influence of corrections on correlation with neutron monitor data is discussed.
Motivation & Objective
- To assess the impact of atmospheric pressure and temperature on muon flux variability at ground and underground sites.
- To apply an integral method for temperature correction using GFS atmospheric temperature profiles.
- To improve the sensitivity of muon flux measurements to non-atmospheric cosmic ray variations by removing meteorological noise.
- To validate correction effectiveness through spectral analysis and correlation with neutron monitor data.
- To establish a robust, data-driven correction framework for long-term cosmic ray monitoring at low-background sites.
Proposed method
- Applied the integral method to compute temperature correction coefficients using atmospheric temperature profiles from the GFS model.
- Used barometric coefficient formula: (δI/I)ₚ = β·δP, with δP = P - P_B, to quantify pressure-induced flux variations.
- Combined pressure and temperature corrections by normalizing pressure data from five local stations and interpolating to 5-minute resolution.
- Integrated temperature coefficient density functions (α(h)) over atmospheric depth to compute (δI/I)ₜ = ∫₀ʰ₀ α(h)·δT(h)·dh.
- Employed cubic spline interpolation for 6-hour GFS temperature data to achieve 5-minute temporal resolution.
- Validated model temperature profiles against radiosonde data, using ground-level measurements for the lowest isobaric level.
Experimental results
Research questions
- RQ1How do pressure and temperature variations affect muon flux at ground and underground locations in Belgrade?
- RQ2To what extent does applying pressure and temperature corrections reduce spurious variability in muon flux time series?
- RQ3Can the GFS model provide sufficiently accurate atmospheric temperature profiles for muon flux correction in the Belgrade region?
- RQ4How does temperature correction impact the spectral power of annual periodicity in muon flux?
- RQ5Does the corrected muon flux show improved correlation with neutron monitor data, indicating enhanced sensitivity to primary cosmic ray variations?
Key findings
- Pressure and temperature corrections significantly reduce non-cosmic-ray-induced variability in muon flux at both ground level and 25 m.w.e. underground.
- The spectral analysis shows a marked reduction in the power of the annual periodicity peak after temperature correction, indicating effective removal of thermal modulation.
- Barometric coefficients for 2008–2015 were derived from linear fits of normalized flux vs. pressure variation, with yearly values reported in Figure 4.
- Temperature coefficient density functions (Fig. 6) show distinct differences between surface and underground conditions, supporting depth-dependent correction.
- Post-correction muon flux time series show improved agreement with BAKSAN neutron monitor data in 2015, as shown in Figure 9, supporting enhanced sensitivity to primary cosmic ray variations.
- The GFS model provides adequate temperature profiles for correction purposes, with good agreement to radiosonde data except at the lowest isobaric level.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.