Skip to main content
QUICK REVIEW

[Paper Review] Effect of sputter deposited ZnO thin layers on magnetoimpedance response and field sensitivity of Co-based micro-wires

A. Dadsetan, M. Almasi Kashi|arXiv (Cornell University)|Nov 1, 2018
Metallic Glasses and Amorphous AlloysEngineering20 references3 citations
TL;DR

This study demonstrates that sputter-deposited ZnO thin films enhance the magnetoimpedance (MI) response and field sensitivity of Co-based amorphous micro-wires. By optimizing ZnO thickness at 240 nm, MI% increased from 227% to 406% and field sensitivity rose from 1.7%/Oe to 4.99%/Oe, with structural and magnetic characterization confirming the role of ZnO in modulating permeability and MI performance.

ABSTRACT

Semiconductive ZnO has shown to be a fascinating element for application in high-performance sensors. ZnO with various thicknesses (87-500 nm) was deposited on the surface of Co-based amorphous micro-wire (Co68.15Fe4.35Si12.5B15) using magnetron sputtering technique and the magnetoimpedance (MI) response was evaluated. The MI% increases monotonously up to the 240 nm thickness of the ZnO layer. By further increase in the ZnO layer thickness the MI% decreases. MI response and field sensitivity increased from 227% and 1.7 %/Oe for bare micro-wire up to 406% and 4.99 %/Oe for ZnO deposited micro-wire with a thickness of 240 nm. The x-ray diffraction (XRD) and scanning electron microscopy (SEM) were used to characterize the structural grown ZnO layers. Vibrating sample magnetometry (VSM) was used to reveal the role of the ZnO thin layer in the MI response. The same trend of increase and decrease in the MI% by thickness was observed for the transverse permeability of the samples determined by VSM. The obtained results address a simple way to achieve high MI response and sensitivity with selective surface sensing.

Motivation & Objective

  • To investigate the influence of sputter-deposited ZnO thin films on the magnetoimpedance (MI) response of Co-based amorphous micro-wires.
  • To determine the optimal ZnO thickness that maximizes MI response and field sensitivity for sensor applications.
  • To understand the structural and magnetic mechanisms behind the observed MI enhancement via ZnO capping.
  • To explore a simple, scalable surface engineering approach for improving high-sensitivity magnetic field sensors.

Proposed method

  • ZnO thin films with thicknesses ranging from 87 to 500 nm were deposited on Co68.15Fe4.35Si12.5B15 amorphous micro-wires using magnetron sputtering.
  • Magnetoimpedance (MI) response was measured to evaluate the electrical impedance variation under applied magnetic fields.
  • X-ray diffraction (XRD) and scanning electron microscopy (SEM) were used to characterize the structural properties of the ZnO layers.
  • Vibrating sample magnetometry (VSM) was employed to measure transverse permeability and correlate it with MI behavior.
  • The relationship between ZnO thickness and MI response was systematically analyzed to identify the optimal thickness.
  • Field sensitivity was calculated from the slope of the MI response curve near zero magnetic field.

Experimental results

Research questions

  • RQ1How does the thickness of sputter-deposited ZnO layers affect the magnetoimpedance response of Co-based micro-wires?
  • RQ2What is the optimal ZnO thickness that maximizes field sensitivity and MI percentage in these micro-wires?
  • RQ3How do structural and magnetic properties of ZnO layers correlate with the observed MI performance?
  • RQ4To what extent does ZnO modification enhance the transverse permeability and MI response compared to bare micro-wires?

Key findings

  • The magnetoimpedance percentage (MI%) increased monotonically with ZnO thickness up to 240 nm, reaching a maximum of 406%.
  • Beyond 240 nm, further ZnO thickness increase led to a decrease in MI%, indicating an optimal thickness for performance.
  • Field sensitivity improved from 1.7%/Oe in bare micro-wires to 4.99%/Oe at 240 nm ZnO thickness, representing a significant enhancement.
  • The transverse permeability measured by VSM followed the same trend as MI%, confirming the magnetic contribution of ZnO to the response.
  • XRD and SEM analysis confirmed the structural integrity and uniformity of ZnO layers across the tested thickness range.
  • The results demonstrate a scalable, surface-engineering approach to achieve high-sensitivity magnetic sensors using ZnO-coated micro-wires.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.