This study investigates light collection efficiency in plastic scintillating counters with embedded wavelength-shifting (WLS) fibers using 855-MeV electron beam tests at MAMI. It demonstrates that a 1.5-mm-diameter WLS fiber increases light yield by 94.2% compared to a fiberless reference counter, with peak gains occurring within 10 cm transverse distance, and models the total light yield as a sum of direct and indirect light collection components.

ABSTRACT

The light collection of several fiber configurations embedded in a box-shaped plastic scintillating counter was studied by scanning with minimum ionizing electrons. The light was read out by silicon photomultipliers at both ends. The light yield produced by the 855-MeV beam of the Mainz Microtron showed a strong dependence on the transverse distance from the beam position to the fibers. The observations were modeled by attributing the collection of indirect light inside of the counter and of direct light reaching a fiber to the total light yield. The light collection with fibers was compared to that of a scintillating counter without fibers. These studies were carried out within the development of plastic scintillating detectors as an active veto system for the DarkMESA electron beam-dump experiment that will search for light dark matter particles in the MeV mass range.

Motivation & Objective

  • To optimize light collection in box-shaped plastic scintillating counters for use in the DarkMESA electron beam-dump experiment.
  • To evaluate the performance of various WLS fiber configurations (diameter, geometry, bundling) in enhancing light yield.
  • To quantify the transverse dependence of light collection relative to fiber position.
  • To model light yield as a function of distance from beam interaction point, distinguishing direct and indirect light contributions.
  • To inform the design of a compact, cost-effective, and highly efficient active veto system for MeV-scale dark matter detection.

Proposed method

  • Scintillating counters of size 50 × 25 × 2 cm³ were fabricated using EJ-200 plastic with polished surfaces to promote total internal reflection.
  • Different WLS fiber configurations (1-mm round, 1.5-mm round, 2-mm square, and 4×1-mm round bundle) were embedded in grooves and sealed with optical cement.
  • Light was read out using four 6×6 mm² SiPMs per end, with dedicated preamplifiers, operational amplifiers, and DACs for bias voltage control.
  • Electron beam tests were performed at the Mainz Microtron (MAMI) using 855-MeV minimum ionizing electrons to simulate energy deposition.
  • Calibration was performed using a reference counter without fibers, and light yield was measured as photoelectron (p.e.) response per MeV.
  • A two-component model was applied to separate contributions: direct light reaching the fiber and indirect light collected via total internal reflection within the scintillator.

Experimental results

Research questions

  • RQ1How does the light yield in a scintillating counter depend on the transverse distance between the beam interaction point and embedded WLS fibers?
  • RQ2What is the relative contribution of direct light reaching the fiber versus indirect light collected via internal reflection to the total light yield?
  • RQ3Which WLS fiber configuration (diameter, geometry, bundling) maximizes light collection efficiency in a 2-cm-thick scintillator?
  • RQ4How does the light yield vary across different fiber configurations compared to a fiberless reference counter?
  • RQ5To what extent does the position of the interaction point affect the signal response in fiber-readout scintillators?

Key findings

  • A 1.5-mm-diameter round WLS fiber increased the light yield by 94.2% compared to the fiberless reference counter, with gains of 50.3% from direct light and 43.9% from indirect light.
  • The light yield gain was strongly dependent on transverse distance, peaking within ±10 cm of the fiber, indicating optimal performance when interactions occur near the fiber.
  • The 1-mm round fiber configuration yielded only 6.2% gain over the reference, while the 4×1-mm bundle achieved 49.9% gain, showing diminishing returns for smaller or bundled fibers.
  • The model attributing total light yield to the sum of direct and indirect light contributions provided a good fit to the data, with reduced chi-squared values between 1.2 and 3.1.
  • The transverse position sensitivity of the signal response introduces challenges for uniformity but may enable improved position resolution when combined with multi-SiPM readout.
  • The results support placing WLS fibers within 10 cm of the interaction region to maximize light collection efficiency in veto counters for MeV-scale dark matter experiments.