[Paper Review] End-to-End Sequential Sampling and Reconstruction for MRI
This paper proposes an end-to-end differentiable framework that jointly learns sequential k-space sampling and image reconstruction for accelerated MRI. By leveraging intermediate measurements during acquisition, the model adaptively selects informative k-space samples, achieving state-of-the-art performance—outperforming prior methods on 96.96% of test samples at 4× acceleration on the fastMRI knee dataset.
Accelerated MRI shortens acquisition time by subsampling in the measurement $κ$-space. Recovering a high-fidelity anatomical image from subsampled measurements requires close cooperation between two components: (1) a sampler that chooses the subsampling pattern and (2) a reconstructor that recovers images from incomplete measurements. In this paper, we leverage the sequential nature of MRI measurements, and propose a fully differentiable framework that jointly learns a sequential sampling policy simultaneously with a reconstruction strategy. This co-designed framework is able to adapt during acquisition in order to capture the most informative measurements for a particular target. Experimental results on the fastMRI knee dataset demonstrate that the proposed approach successfully utilizes intermediate information during the sampling process to boost reconstruction performance. In particular, our proposed method can outperform the current state-of-the-art learned $κ$-space sampling baseline on over 96% of test samples. We also investigate the individual and collective benefits of the sequential sampling and co-design strategies.
Motivation & Objective
- Address the challenge of slow MRI acquisition by accelerating data collection through intelligent sampling.
- Overcome limitations of static, pre-designed sampling patterns that do not adapt to individual anatomical features.
- Improve reconstruction fidelity by co-designing the sampling policy and reconstruction network in a joint, differentiable framework.
- Explore the benefits of sequential sampling—where sampling decisions adapt during acquisition—compared to non-sequential approaches.
- Demonstrate that end-to-end training enables more effective co-design than non-differentiable or separate optimization strategies.
Proposed method
- Formulate MRI acquisition as a sequential decision process over T steps, where each step includes a differentiable sampler and reconstructor.
- Use a neural network-based sampler that selects k-space locations based on intermediate reconstructed images and prior measurements.
- Train the entire system end-to-end using backpropagation through time, enabling gradient-based optimization of both sampling and reconstruction components.
- Introduce a differentiable reconstruction network that processes partial k-space data and generates increasingly accurate images at each step.
- Implement a joint loss function that optimizes reconstruction quality (e.g., SSIM, MSE) while guiding the sampler toward informative k-space regions.
- Replace the input to the reconstructor in non-sequential baselines with random tensors to isolate the benefit of sequential adaptation.
Experimental results
Research questions
- RQ1Can a jointly optimized, sequential sampling and reconstruction framework outperform non-sequential, pre-designed sampling patterns in accelerated MRI?
- RQ2To what extent does end-to-end differentiable training improve reconstruction performance compared to non-differentiable or separate training of sampler and reconstructor?
- RQ3How does increasing the number of sequential sampling steps affect reconstruction quality and convergence?
- RQ4What is the individual and collective contribution of sequential sampling and co-design to overall performance improvement?
- RQ5Can the framework generalize across different acceleration factors and anatomical structures in real-world MRI data?
Key findings
- The proposed 4-step sequential model outperforms the LOUPE baseline on 96.96% of test samples at 4× acceleration, 92.62% at 8×, and 76.91% at 16× on the fastMRI single-coil knee dataset.
- Even a single sequential step consistently improves performance over non-sequential baselines, demonstrating the value of adaptive sampling.
- Performance improves with more sequential steps, but with diminishing returns, indicating that 4 steps provide strong gains without overfitting.
- Co-designing the sampler and reconstructor leads to a 2.33–2.51 SSIM improvement over a fixed reconstructor trained with random sampling at 4× acceleration.
- The ablation study confirms that performance gains are due to sequential adaptation and co-design, not merely architectural improvements.
- The framework achieves state-of-the-art results across all tested acceleration factors, with statistically significant improvements over prior learned non-sequential baselines.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.