Skip to main content
QUICK REVIEW

[Paper Review] Enhanced Microgrid Power Flow Incorporating Hierarchical Control

Fei Feng, Peng Zhang|arXiv (Cornell University)|Jan 12, 2020
Microgrid Control and OptimizationEngineering5 references5 citations
TL;DR

This paper proposes an Enhanced Microgrid Power Flow (EMPF) method based on an augmented Newton-Raphson approach that integrates hierarchical control effects—specifically droop and secondary controls—into microgrid power flow analysis. By deriving a modified Jacobian matrix that accounts for P/f and Q/V droop coefficients and secondary control modes (RPS, VR, ST), EMPF enables accurate, robust, and fast power flow solutions in both radial and meshed microgrids, with demonstrated convergence speed and accuracy superior to existing methods.

ABSTRACT

An enhanced microgrid power flow (EMPF) is devised to incorporate hierarchical control effects. The new contributions are threefold: 1) an advanced-hierarchical-control-based Newton approach is established to accurately assess power sharing and voltage regulation effects; 2) a modified Jacobian matrix is derived to incorporate droop control and various secondary control modes; and 3) the secondary adjustment is calculated on top of the droop-control-based power flow results to ensure a robust Newton solution. Case studies validate that EMPF is efficacious and efficient and can serve as a powerful tool for microgrid operation and monitoring, especially for those highly meshed microgrids in urban areas.

Motivation & Objective

  • To address the lack of a unified power flow method that accurately models hierarchical control in islanded microgrids.
  • To overcome limitations of existing methods like backward/forward sweep and standard Newton-Raphson in handling meshed networks and secondary controls.
  • To develop a plug-and-play, modular power flow formulation that supports future extension to networked microgrids.
  • To ensure robust convergence and accurate representation of power sharing and voltage regulation under various control modes.
  • To provide a scalable and efficient tool for microgrid operation, monitoring, and stability studies.

Proposed method

  • Introduces DER buses as a new bus type to represent distributed energy resources (DERs) with droop and secondary control.
  • Develops an augmented Newton-type power flow formulation that includes frequency (f) as a state variable, enabling droop control modeling.
  • Derives a modified Jacobian matrix that incorporates P/f and Q/V droop coefficients and secondary control dynamics through analytical partial derivatives.
  • Incorporates secondary control modes (RPS, VR, ST) by adjusting the Jacobian elements based on control-specific equations and constraints.
  • Performs secondary adjustments on top of droop-based power flow results to ensure solution robustness and convergence.
  • Uses a reference voltage angle at an arbitrary DER bus to replace the traditional slack bus, enabling application in islanded microgrids.

Experimental results

Research questions

  • RQ1Can a Newton-based power flow method accurately model hierarchical control effects in microgrids without a slack bus?
  • RQ2How does the modified Jacobian matrix enable accurate representation of power sharing and voltage regulation under droop and secondary controls?
  • RQ3What is the convergence performance of the EMPF method in both radial and meshed microgrid configurations?
  • RQ4How does EMPF compare in accuracy and speed to existing backward/forward sweep and Newton methods?
  • RQ5Can EMPF be used as a reliable initial solution for microgrid stability and security studies?

Key findings

  • EMPF achieves faster convergence than the method in [1], requiring only 16 iterations in VR mode compared to 173 iterations, with tighter convergence tolerances.
  • Voltage profiles are significantly improved under secondary control: for example, bus 27 voltage under VR mode is 0.9981 p.u., 1.44% closer to nominal than under droop-only control.
  • In RPS mode, all DERs (leader and followers) inject equal reactive power (0.93 p.u.), confirming successful proportional reactive power sharing.
  • The meshed microgrid exhibits smoother voltage profiles than the radial system, with bus 30 voltage 0.41% higher under droop control due to enhanced voltage support from DER 25.
  • CPU time for EMPF is consistently low (0.48–0.87 s), with iteration counts stable across control modes, indicating robust performance.
  • EMPF is validated as correct by matching results with [1] in radial microgrid tests, confirming its accuracy and reliability.