[Paper Review] Enhancing Breast Cancer Risk Prediction by Incorporating Prior Images
This paper introduces PRIME+, a transformer-based deep learning model that enhances breast cancer risk prediction by analyzing changes in breast tissue over time using prior and current mammograms. By leveraging temporal patterns—especially changes in breast density—it achieves a significant C-index improvement from 0.68 to 0.73 (p < 0.05) over state-of-the-art single-timepoint models.
Recently, deep learning models have shown the potential to predict breast cancer risk and enable targeted screening strategies, but current models do not consider the change in the breast over time. In this paper, we present a new method, PRIME+, for breast cancer risk prediction that leverages prior mammograms using a transformer decoder, outperforming a state-of-the-art risk prediction method that only uses mammograms from a single time point. We validate our approach on a dataset with 16,113 exams and further demonstrate that it effectively captures patterns of changes from prior mammograms, such as changes in breast density, resulting in improved short-term and long-term breast cancer risk prediction. Experimental results show that our model achieves a statistically significant improvement in performance over the state-of-the-art based model, with a C-index increase from 0.68 to 0.73 (p < 0.05) on held-out test sets.
Motivation & Objective
- To improve breast cancer risk prediction by incorporating longitudinal mammographic data, which is currently underutilized in deep learning models.
- To address the limitation of existing models that rely only on single-timepoint mammograms and fail to capture dynamic tissue changes.
- To develop a method that mimics radiologists’ comparative reading approach by modeling temporal changes in breast density and texture.
- To validate the model’s performance across short-term and long-term risk prediction settings, particularly in cases of changing breast density.
- To demonstrate that prior mammograms significantly enhance predictive performance, especially in high-risk subgroups with density progression.
Proposed method
- Uses a ResNet-34 backbone pre-trained on ImageNet to extract features from both prior and current mammograms, producing $x_{prior}$ and $x_{curr}$.
- Employs a transformer decoder with cross-attention to fuse and compare features from prior and current exams, modeling temporal relationships.
- Concatenates the fused representation $x_{CPC}$ with base hazard $\theta_b$ and time-dependent hazard heads $\theta_u$ to predict the cumulative hazard function $\hat{H}(t|x)$.
- Applies survival analysis with right-censored data, using the cumulative hazard function to estimate time-to-event risk for breast cancer.
- Trains the model end-to-end using a loss function optimized for survival outcomes, including censored observations.
- Utilizes a self-supervised density prediction model to assign BI-RADS categories for breast density when ground truth is unavailable.
Experimental results
Research questions
- RQ1Can incorporating prior mammograms improve the performance of deep learning models in predicting breast cancer risk compared to single-timepoint models?
- RQ2How does the model’s performance vary in cases where breast density changes between prior and current exams compared to stable cases?
- RQ3Does the model outperform state-of-the-art methods in both short-term and long-term risk prediction tasks?
- RQ4What is the contribution of temporal changes—especially in breast density—to improved risk stratification?
- RQ5Can the model effectively learn from subtle tissue changes that radiologists detect through comparative reading?
Key findings
- PRIME+ achieves a statistically significant C-index improvement from 0.68 to 0.73 (p < 0.05) on held-out test sets compared to the state-of-the-art baseline.
- In cases of breast density change from prior to current exam, PRIME+ improves 3-year AUC from 0.56 (baseline) to 0.74, demonstrating strong long-term prediction capability.
- For patients with no density change, PRIME+ maintains high performance, with a 1-year AUC of 0.74 and 4-year AUC of 0.76, outperforming the baseline across all timepoints.
- The model performs better in fatty breasts (C-index: 0.70) than in dense breasts (C-index: 0.68), though both groups show consistent improvement over baseline.
- The model’s attention mechanism effectively captures temporal changes, particularly in texture and density patterns, which are critical for long-term risk prediction.
- Subgroup analysis confirms that the model’s advantage is most pronounced in patients with progressive breast density, a known high-risk indicator.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.