Skip to main content
QUICK REVIEW

[Paper Review] High-Resolution Breast Cancer Screening with Multi-View Deep Convolutional Neural Networks

Krzysztof J. Geras, Stacey Wolfson|arXiv (Cornell University)|Mar 21, 2017
AI in cancer detectionComputer Science3 references195 citations
TL;DR

The authors develop a multi-view deep convolutional network (MV-DCN) that processes four high-resolution mammography views to predict BI-RADS categories, demonstrating data-size and resolution importance and competitive reader-study performance.

ABSTRACT

Advances in deep learning for natural images have prompted a surge of interest in applying similar techniques to medical images. The majority of the initial attempts focused on replacing the input of a deep convolutional neural network with a medical image, which does not take into consideration the fundamental differences between these two types of images. Specifically, fine details are necessary for detection in medical images, unlike in natural images where coarse structures matter most. This difference makes it inadequate to use the existing network architectures developed for natural images, because they work on heavily downscaled images to reduce the memory requirements. This hides details necessary to make accurate predictions. Additionally, a single exam in medical imaging often comes with a set of views which must be fused in order to reach a correct conclusion. In our work, we propose to use a multi-view deep convolutional neural network that handles a set of high-resolution medical images. We evaluate it on large-scale mammography-based breast cancer screening (BI-RADS prediction) using 886,000 images. We focus on investigating the impact of the training set size and image size on the prediction accuracy. Our results highlight that performance increases with the size of training set, and that the best performance can only be achieved using the original resolution. In the reader study, performed on a random subset of the test set, we confirmed the efficacy of our model, which achieved performance comparable to a committee of radiologists when presented with the same data.

Motivation & Objective

  • Investigate how to apply deep learning to full-resolution, multi-view mammography without downscaling.
  • Evaluate the impact of training set size on BI-RADS prediction performance.
  • Assess the effect of input image resolution on model accuracy.
  • Visualize model decisions and compare with radiologist performance in a reader study.

Proposed method

  • Develop an MV-DCN with four view-specific columns (L-CC, R-CC, L-MLO, R-MLO) whose view representations are concatenated for final classification.
  • Process each view with a dedicated convolutional–pooling stack and apply global average pooling before concatenation.
  • Train end-to-end with shared weights across left/right view pairs, data augmentation, input noise, and dropout; optimize with Adam on large high-resolution inputs (2600x2000).
  • Use aggressive initial downsampling in early layers to keep high-resolution inputs feasible, while averaging final feature maps before concatenation to reduce dimensionality.

Experimental results

Research questions

  • RQ1Does keeping high-resolution input improve BI-RADS prediction compared to downscaled approaches?
  • RQ2How does the size of the training data affect MV-DCN performance on BI-RADS classification?
  • RQ3What is the effect of input resolution on predictive accuracy for BI-RADS categories?
  • RQ4How does MV-DCN performance compare to radiologists and to an ensemble of radiologists and MV-DCN?
  • RQ5Can confidence (prediction entropy) be used to identify high-accuracy subsets of predictions?

Key findings

  • Performance improves with larger training data (macAUC increases as training size grows from 1% to 100%).
  • Downscaling inputs degrades performance; full-resolution inputs yield best results (e.g., higher macAUC with full input than scaled inputs).
  • Higher confidence predictions (lower entropy) correlate with higher accuracy (HC-macAUC surpasses macAUC on high-confidence subsets).
  • In reader study, radiologists achieved macAUC of 0.704, MV-DCN achieved 0.688, and an ensemble of radiologists and MV-DCN achieved 0.735.
  • The MV-DCN with four-view inputs can match committee-level radiologist performance on the same data for BI-RADS prediction.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.