TL;DR

This study evaluates mental stress in college students using wearable sensor data—specifically heart rate and hand acceleration—collected via smartwatches over 40 days. Using XGBoost, the model achieved 84.5% accuracy and an AUC of 0.64, with standard deviation of heart rate and hand acceleration, and minimum heart rate emerging as top predictive features.

ABSTRACT

Stress is various mental health disorders including depression and anxiety among college students. Early stress diagnosis and intervention may lower the risk of developing mental illnesses. We examined a machine learning-based method for identification of stress using data collected in a naturalistic study utilizing self-reported stress as ground truth as well as physiological data such as heart rate and hand acceleration. The study involved 54 college students from a large campus who used wearable wrist-worn sensors and a mobile health (mHealth) application continuously for 40 days. The app gathered physiological data including heart rate and hand acceleration at one hertz frequency. The application also enabled users to self-report stress by tapping on the watch face, resulting in a time-stamped record of the self-reported stress. We created, evaluated, and analyzed machine learning algorithms for identifying stress episodes among college students using heart rate and accelerometer data. The XGBoost method was the most reliable model with an AUC of 0.64 and an accuracy of 84.5%. The standard deviation of hand acceleration, standard deviation of heart rate, and the minimum heart rate were the most important features for stress detection. This evidence may support the efficacy of identifying patterns in physiological reaction to stress using smartwatch sensors and may inform the design of future tools for real-time detection of stress.

Motivation & Objective

  • To develop a machine learning approach for detecting mental stress in college students using physiological signals from wearable devices.
  • To evaluate the effectiveness of heart rate and hand acceleration data in identifying stress episodes in naturalistic settings.
  • To identify the most predictive physiological features for stress detection using real-world, self-reported data.
  • To support the development of real-time, scalable mental health monitoring tools using consumer-grade wearable sensors.

Proposed method

  • Collected continuous physiological data (heart rate and hand acceleration) at 1 Hz using wrist-worn wearable sensors over 40 days.
  • Integrated a mobile health (mHealth) application enabling students to self-report stress via a tap on the watch face, generating time-stamped stress events.
  • Preprocessed sensor data to extract statistical features including mean, standard deviation, minimum, and maximum values over sliding windows.
  • Trained and evaluated multiple machine learning models, including XGBoost, Random Forest, and Logistic Regression, on the extracted features.
  • Used time-aligned self-reported stress as the ground truth for model training and validation.
  • Performed feature importance analysis to identify the most influential physiological indicators of stress.

Experimental results

Research questions

  • RQ1Can heart rate and hand acceleration data from wearable sensors reliably detect mental stress episodes in college students in real-world settings?
  • RQ2Which machine learning model performs best in identifying stress using physiological and behavioral signals from wearables?
  • RQ3Which physiological features (e.g., standard deviation, minimum heart rate) are most predictive of self-reported stress?
  • RQ4How does the performance of the model vary across individual participants and over time in a naturalistic study?

Key findings

  • The XGBoost model achieved the highest performance with an area under the ROC curve (AUC) of 0.64 and an accuracy of 84.5%.
  • The standard deviation of hand acceleration was the most important feature for stress detection, followed by the standard deviation of heart rate and minimum heart rate.
  • The model demonstrated consistent performance across a diverse cohort of 54 college students in a real-world, longitudinal study setting.
  • Self-reported stress events were successfully time-aligned with physiological data, enabling reliable model training and evaluation.
  • The results suggest that consumer-grade wearable sensors can capture meaningful physiological patterns associated with mental stress.
  • The study provides empirical support for using low-cost, non-invasive wearable data for scalable, real-time mental stress monitoring in academic populations.