Skip to main content
QUICK REVIEW

[Paper Review] FAIR evaluation of ten widely used chemical datasets: Lessons learned and recommendations

Marcos Da Silveira, Oona Freudenthal|arXiv (Cornell University)|Jul 22, 2024
Research Data Management PracticesComputer Science3 citations
TL;DR

This study evaluates the FAIRness (Findability, Accessibility, Interoperability, Reusability) of ten widely used chemical datasets from Europe and North America using both manual questionnaires and automated tools (F-UJI, FAIR Checker). Despite high manual compliance with FAIR principles, automated tools scored only up to 54/100, revealing critical gaps due to non-standard metadata and non-interpretable formats, highlighting the need for improved metadata standards and tool compatibility in chemical data platforms.

ABSTRACT

This document focuses on databases disseminating data on (hazardous) substances found on the North American and the European (EU) market. The goal is to analyse the FAIRness (Findability, Accessibility, Interoperability and Reusability) of published open data on these substances and to qualitatively evaluate to what extend the selected databases already fulfil the criteria set out in the commission draft regulation on a common data chemicals platform. We implemented two complementary approaches: Manual, and Automatic. The manual approach is based on online questionnaires. These questionnaires provide a structured approach to evaluating FAIRness by guiding users through a series of questions related to the FAIR principles. They are particularly useful for initiating discussions on FAIR implementation within research teams and for identifying areas that require further attention. Automated tools for FAIRness assessment, such as F-UJI and FAIR Checker, are gaining prominence and are continuously under development. Unlike manual tools, automated tools perform a series of tests automatically starting from a dereferenceable URL to the data resource to be evaluated. We analysed ten widely adopted datasets managed in Europe and North America. The highest score from automatic analysis was 54/100. The manual analysis shows that several FAIR metrics were satisfied, but not detectable by automatic tools because there is no metadata, or the format of the information was not a standard one. Thus, it was not interpretable by the tool. We present the details of the analysis and tables summarizing the outcomes, the issues, and the suggestions to address these issues.

Motivation & Objective

  • To assess the FAIRness of ten widely used chemical datasets from Europe and North America.
  • To evaluate how well these datasets meet the criteria outlined in the EU's draft regulation for a common chemicals data platform.
  • To identify discrepancies between manual FAIR assessments and automated tool evaluations.
  • To provide actionable recommendations for improving metadata quality and interoperability in chemical data repositories.

Proposed method

  • Conducted manual FAIR evaluation using structured online questionnaires to systematically assess Findability, Accessibility, Interoperability, and Reusability.
  • Applied automated FAIR assessment tools—F-UJI and FAIR Checker—using dereferenceable URLs to test data resources objectively.
  • Compared results from manual assessments with automated tool outputs to detect inconsistencies.
  • Analyzed datasets for metadata completeness, standardization, and machine-readability to explain discrepancies.
  • Identified cases where manual compliance was high but automated tools failed due to non-standard or non-structured metadata.
  • Provided detailed tables and recommendations based on findings to guide data providers and platform developers.

Experimental results

Research questions

  • RQ1To what extent do widely used chemical datasets in Europe and North America comply with the FAIR principles?
  • RQ2Why do automated FAIR assessment tools report lower scores than manual evaluations for the same datasets?
  • RQ3What specific metadata and formatting issues prevent automated tools from detecting FAIR compliance?
  • RQ4How do current data practices align with the requirements of the EU’s proposed common chemicals data platform?
  • RQ5What recommendations can improve FAIRness in chemical data repositories, especially for automated tool compatibility?

Key findings

  • The highest automated FAIRness score achieved was 54 out of 100, indicating significant room for improvement in machine-evaluable data quality.
  • Manual assessments revealed strong compliance with FAIR principles in areas such as data accessibility and reusability, even when automated tools failed to detect it.
  • A major reason for tool failure was the absence of standardized metadata or non-structured data formats that automated tools could not interpret.
  • Several datasets met FAIR criteria in practice but were not recognized by automated tools due to lack of machine-readable metadata.
  • The study identified that current automated tools are limited by their reliance on specific metadata standards and cannot detect FAIR compliance when metadata is missing or non-compliant.
  • The findings underscore the need for harmonized metadata standards and improved tooling to align with real-world data practices in chemical data management.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.