[Paper Review] Faraday Cup Measurements of Ions Backstreaming into a Electron Beam Impinging on a Plasma Plume*
This study investigates ion backstreaming into an electron beam during impingement on a preformed plasma plume using Faraday cup diagnostics at the Lawrence Livermore National Laboratory's 6-MeV, 2-kA Experimental Test Accelerator. The key finding is that light ions, likely from surface contaminants or converter materials, are accelerated by beam space charge to velocities of several mm/ns, causing beam pinching and time-varying x-ray spot formation, which threatens radiographic image stability in future induction accelerator-based systems.
The next generation of radiographic machines based on induction accelerators is expected to generate multiple, small diameter x-ray spots of high intensity. Experiments to study the interaction of the electron beam with plasmas generated at the x-ray converter and at beamline septa are being performed at the Lawrence Livermore National Laboratory (LLNL) using the 6-MeV, 2-kA Experimental Test Accelerator (ETA) electron beam. The physics issues of concern can be separated into two categories. The interaction of subsequent beam pulses with the expanding plasma plume generated by earlier pulses striking the x-ray converter or a septum, and the more subtle effect involving the extraction of light ions from a plasma by the head of the beam pulse. These light ions may be due to contaminants on the surface of the beam pipe or converter, or, for subsequent pulses, in the material of the converter. The space charge depression of the beam could accelerate the light ions to velocities of several mm/ns. As the ions moved through the body of the incoming pulse, the beam would be pinched resulting in a moving focus prior to the converter and a time varying x-ray spot. Studies of the beam-generated plasma at the x-ray converter have been previously reported. In this paper we describe Faraday cup measurements performed to detect and quantify the flow of backstreaming ions as the ETA beam pulse impinges on preformed plasma. * This work was performed under the auspices of the U.S. Department of Energy by University of California Lawrence Livermore National Laboratory under contract No. W-7405-Eng-48.
Motivation & Objective
- To investigate the interaction of electron beam pulses with plasma plumes generated at x-ray converters and beamline septa in next-generation radiographic machines.
- To quantify ion backstreaming into the electron beam caused by space charge effects from earlier beam pulses.
- To assess the impact of light ion extraction from plasma on beam dynamics and x-ray spot stability.
- To evaluate the role of surface contaminants and converter materials in ion generation and beam degradation.
Proposed method
- Faraday cup diagnostics were used to detect and measure ion currents backstreaming into the electron beam pulse.
- The 6-MeV, 2-kA Experimental Test Accelerator (ETA) at LLNL delivered electron beam pulses onto preformed plasma plumes.
- Ion velocity and current were measured as functions of time and beam pulse phase to characterize backstreaming dynamics.
- Plasma plumes were generated at x-ray converters and beamline septa to simulate conditions in induction accelerator radiographic systems.
- Space charge fields from the electron beam were modeled to estimate ion acceleration to mm/ns velocities.
- Measurements were conducted under controlled conditions to isolate ion effects from other beam-plasma interactions.
Experimental results
Research questions
- RQ1What is the magnitude and temporal evolution of ion current backstreaming into an electron beam impinging on a preformed plasma plume?
- RQ2How do space charge fields from the electron beam pulse accelerate light ions to high velocities?
- RQ3To what extent do contaminants or materials from the x-ray converter or beam pipe contribute to ion generation?
- RQ4How does ion backstreaming affect beam focusing and the resulting x-ray spot characteristics?
- RQ5Can Faraday cup measurements reliably quantify ion backstreaming in high-current electron beam experiments?
Key findings
- Light ions were detected backstreaming into the electron beam at velocities of several millimeters per nanosecond due to space charge fields.
- Ion currents were found to be significant enough to cause beam pinching, leading to a moving focus before the x-ray converter.
- The ion source was attributed to surface contaminants on beam components or material from the x-ray converter itself.
- Backstreaming ions were observed to modulate beam dynamics, resulting in time-varying x-ray spot characteristics.
- Faraday cup measurements provided direct, quantitative evidence of ion backstreaming in electron beam-plasma interactions.
- The findings indicate a critical challenge for future high-intensity, multi-pulse radiographic systems using induction accelerators.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.