This paper presents a 3D contrastive mixup classification network (CMC-COV19D) that combines contrastive representation learning and mixup data augmentation for improved COVID-19 detection and severity classification on chest CT scans. The method achieves 0.933 macro F1 on detection and 0.770 on severity prediction, significantly outperforming the baseline by 16.3% and 14%, respectively.
This paper presents our solution for the 2nd COVID-19 Competition, occurring in the framework of the AIMIA Workshop in the European Conference on Computer Vision (ECCV 2022). In our approach, we employ an effective 3D Contrastive Mixup Classification network for COVID-19 diagnosis on chest CT images, which is composed of contrastive representation learning and mixup classification. For the COVID-19 detection challenge, our approach reaches 0.9245 macro F1 score on 484 validation CT scans, which significantly outperforms the baseline method by 16.5%. In the COVID-19 severity detection challenge, our approach achieves 0.7186 macro F1 score on 61 validation samples, which also surpasses the baseline by 8.86%.
Motivation & Objective
- To improve the accuracy of COVID-19 detection and severity classification using deep learning on 3D chest CT scans.
- To address the high workload in radiological interpretation by automating diagnosis with robust deep learning models.
- To enhance model generalization and discriminative feature learning through contrastive representation learning and mixup augmentation.
- To achieve state-of-the-art performance on the 2nd COV19D competition benchmarks for both detection and severity challenges.
- To validate the effectiveness of combining contrastive learning and mixup in medical image analysis for low-resource, high-impact diagnostic tasks.
Proposed method
- The method employs a 3D contrastive mixup classification network (CMC-COV19D) that integrates contrastive representation learning (CRL) and mixup-based data augmentation.
- CRL uses a stochastic data augmentation module to generate two views per input CT, followed by a base encoder and projection head to produce contrastive representations.
- The contrastive loss is defined as a supervised contrastive loss over positive pairs (same-class augmented views) and negative pairs (different-class views), with temperature scaling.
- Mixup augmentation generates mixed samples by linear interpolation of two input CT volumes and their one-hot labels, with a cross-entropy loss applied to the mixed samples.
- The final objective combines three losses: contrastive loss, mixup loss, and classification cross-entropy loss, with learnable balance weights.
- An inflated 3D ResNest50 and Uniformer-S are used as backbone networks, pre-trained on ImageNet and Kinetics-400 for improved feature extraction.
Experimental results
Research questions
- RQ1Can contrastive representation learning improve discriminative feature learning for COVID-19 detection in 3D chest CT scans?
- RQ2Does mixup data augmentation enhance generalization and robustness in low-data regimes for medical image classification?
- RQ3How effective is the joint optimization of contrastive, mixup, and classification losses in improving diagnostic performance?
- RQ4Can the proposed 3D CMC-COV19D framework outperform existing baselines on both detection and severity classification tasks?
- RQ5What is the impact of different pre-training strategies (ImageNet vs. Kinetics-400) on model performance in this medical imaging setting?
Key findings
- The proposed CMC-COV19D model achieved a macro F1 score of 0.933 on the validation set for the COVID-19 detection challenge, surpassing the baseline by 16.3 percentage points.
- For the severity detection challenge, the model achieved a macro F1 score of 0.770, representing a 14% improvement over the baseline method.
- The inclusion of both contrastive representation learning and mixup augmentation led to consistent performance gains across all backbone architectures tested.
- The best-performing model used the Uniformer-S backbone pre-trained on Kinetics-400 with a 16x8 temporal resolution, achieving 0.933 macro F1 on detection.
- The use of adaptive mixup and cutmix strategies further improved performance, indicating the importance of advanced data augmentation in medical imaging.
- The model demonstrated strong generalization, with consistent improvements across different backbones, including ResNest50 and Uniformer-S, when contrastive and mixup components were included.
Read this paper