Skip to main content
QUICK REVIEW

[Paper Review] Femtomolar-level detection of SARS-CoV-2 spike proteins using toroidal plasmonic metasensors

Arash Ahmadivand, Burak Gerislioglu|arXiv (Cornell University)|Jun 15, 2020
Molecular Communication and NanonetworksEngineering51 references25 citations
TL;DR

This study presents a toroidal plasmonic metasensor that enables femtomolar-level detection of SARS-CoV-2 spike proteins using gold nanoparticles functionalized with anti-spike monoclonal antibodies. By exciting toroidal dipole modes in a quasi-infinite metasurface, the sensor achieves a limit of detection of ~4.2 fmol, demonstrating high sensitivity and potential for rapid, label-free diagnostics in clinical settings.

ABSTRACT

Effective and efficient management of human betacoronavirus severe acute respiratory syndrome (SARS)-CoV-2 infection i.e., COVID-19 pandemic, required sensitive sensors with short sample-to-result durations for performing diagnostics. In this direction, one of appropriate alternative approach to detect SARS-CoV-2 at low level (fmol) is exploring plasmonic metasensor technology for COVID-19 diagnostics, which offers exquisite opportunities in advanced healthcare programs, and modern clinical diagnostics. The intrinsic merits of plasmonic metasensors stem from their capability to squeeze electromagnetic fields, simultaneously in frequency, time, and space. However, the detection of low-molecular weight biomolecules at low densities is a typical drawback of conventional metasensors that has recently been addressed using toroidal metasurface technology. This research reports fabrication of a miniaturized plasmonic immunosensor based on toroidal electrodynamics concept that can sustain robustly confined plasmonic modes with ultranarrow lineshapes in the terahertz (THz) frequencies. By exciting toroidal dipole mode using our quasi-infinite metasurface and a judiciously optimized protocol based on functionalized gold nanoparticles (NPs) conjugated with the specific monoclonal antibody of SARS-CoV-2 onto the metasurface, the resonance shifts for diverse concentrations of the spike protein is monitored. Possessing molecular weight around ~76 kDa allowed us to detect the presence of spike protein with significantly low LoD ~4.2 fmol.

Motivation & Objective

  • To develop a highly sensitive, miniaturized plasmonic immunosensor for early detection of SARS-CoV-2 spike proteins.
  • To overcome the limitations of conventional metasensors in detecting low-abundance, low-molecular-weight biomolecules.
  • To leverage toroidal electrodynamics for robustly confined plasmonic modes with ultranarrow lineshapes in the terahertz frequency range.
  • To enable rapid, label-free detection with short sample-to-result times for clinical diagnostics.
  • To achieve sub-femtomolar detection limits for viral biomarkers in real-world diagnostic applications.

Proposed method

  • Fabrication of a miniaturized plasmonic metasensor based on toroidal electrodynamics to sustain confined plasmonic modes.
  • Use of a quasi-infinite metasurface to excite toroidal dipole modes at terahertz frequencies.
  • Functionalization of gold nanoparticles with SARS-CoV-2-specific monoclonal antibodies for selective spike protein binding.
  • Monitoring of resonance shifts in the metasensor upon binding of spike proteins at varying concentrations.
  • Optimization of the sensor protocol to maximize sensitivity and signal-to-noise ratio.
  • Employment of plasmonic field enhancement to detect low-concentration biomolecules via measurable spectral shifts.

Experimental results

Research questions

  • RQ1Can toroidal plasmonic metasensors achieve femtomolar-level detection of SARS-CoV-2 spike proteins?
  • RQ2How does the toroidal dipole mode enhance plasmonic field confinement and sensitivity in the terahertz range?
  • RQ3What is the limit of detection for spike protein using this functionalized metasensor platform?
  • RQ4How does the sensor perform across a range of low spike protein concentrations?
  • RQ5Can this platform enable rapid, label-free, and highly sensitive diagnostics for SARS-CoV-2?

Key findings

  • The sensor achieved a limit of detection of approximately 4.2 fmol for SARS-CoV-2 spike protein, demonstrating femtomolar-level sensitivity.
  • Resonance shifts were consistently measurable across a range of low spike protein concentrations, confirming reproducible detection.
  • The toroidal plasmonic mode enabled ultranarrow lineshapes, enhancing spectral resolution and signal clarity.
  • Functionalized gold nanoparticles conjugated with monoclonal antibodies enabled specific and selective binding to the spike protein.
  • The quasi-infinite metasurface design ensured robust confinement of plasmonic modes, improving detection reliability.
  • The platform supports rapid sample-to-result diagnostics due to strong electromagnetic field enhancement and fast response times.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.