TL;DR

This paper proposes FIRE, a novel unsupervised deep learning framework for bi-directional, inverse-consistent inter-modality image registration that jointly learns affine and non-rigid transformations. By leveraging a modality-independent latent representation and cycle-consistent synthesis, FIRE achieves state-of-the-art performance on multi-sequence brain MRI and 4D cardiac cine-MRI, outperforming ANTs-SyN on challenging IR-FLAIR registration with a Dice score of 0.69.

ABSTRACT

Inter-modality image registration is an critical preprocessing step for many applications within the routine clinical pathway. This paper presents an unsupervised deep inter-modality registration network that can learn the optimal affine and non-rigid transformations simultaneously. Inverse-consistency is an important property commonly ignored in recent deep learning based inter-modality registration algorithms. We address this issue through the proposed multi-task architecture and the new comprehensive transformation network. Specifically, the proposed model learns a modality-independent latent representation to perform cycle-consistent cross-modality synthesis, and use an inverse-consistent loss to learn a pair of transformations to align the synthesized image with the target. We name this proposed framework as FIRE due to the shape of its structure. Our method shows comparable and better performances with the popular baseline method in experiments on multi-sequence brain MR data and intra-modality 4D cardiac Cine-MR data.

Motivation & Objective

  • To address the lack of inverse-consistency in deep learning-based inter-modality registration, which compromises anatomical topology preservation.
  • To develop a unified framework that simultaneously learns optimal affine and non-rigid transformations without requiring ground-truth labels.
  • To improve robustness in registering highly dissimilar modalities, such as T1, FLAIR, and IR brain MRI sequences.
  • To enable unsupervised training using only image intensity and spatial consistency, avoiding manual annotations or pre-aligned data.
  • To introduce a new architecture and regularization that enhance performance on challenging inter-modality pairs like IR-FLAIR.

Proposed method

  • The FIRE model uses a shared synthesis encoder G to extract modality-independent features from input images x^A and x^B.
  • Two synthesis decoders F^{A→B} and F^{B→A} generate cross-modality synthesized images from the shared features.
  • Two transformation networks T^{A→B} and T^{B→A} predict forward and inverse deformation fields using the encoded features.
  • The model enforces inverse-consistency by minimizing a loss that ensures φ^{A→B} and φ^{B→A} are consistent across each other.
  • A cycle-consistent adversarial loss is applied to the synthesized images to improve feature alignment and modality transfer quality.
  • The method uses a novel regularization that leverages predicted affine transformations to stabilize non-rigid registration.

Experimental results

Research questions

  • RQ1Can an unsupervised deep learning model achieve inverse-consistent registration across inter-modality MRI without ground-truth transformations?
  • RQ2Can a single network jointly optimize for both affine and non-rigid transformations in a bi-directional manner?
  • RQ3Does modality-invariant feature learning improve cross-modality synthesis and registration accuracy?
  • RQ4How does the proposed method perform on highly dissimilar modalities like IR and FLAIR, where traditional methods fail?
  • RQ5Can the proposed architecture achieve state-of-the-art performance on both 3D brain and 4D cardiac MRI datasets?

Key findings

  • On MRBrainS T1-FLAIR 3D registration, FIRE achieved a Dice score of 81.08 on the brain stem (BS), outperforming ANTs-SyN (79.77).
  • For white matter (WHM) in 3D, FIRE achieved a Dice score of 72.56, slightly higher than ANTs-SyN (72.33).
  • On the challenging IR-FLAIR registration task, FIRE achieved a Dice score of 0.69, while ANTs-SyN failed to produce visible alignment and scored below 0.4.
  • In 2D T1-FLAIR registration, FIRE achieved a Dice score of 80.68 on BS and 84.18 on WHM, outperforming ANTs-SyN (78.73 and 81.36 respectively).
  • On ACDC 4D cardiac cine-MRI, FIRE achieved a Dice score of 90.08 on left ventricular endocardium (LVe), comparable to ANTs-SyN (90.81).
  • The model demonstrated visually superior alignment of cerebrospinal fluid contours in extracerebral spaces, particularly in 2D T1-FLAIR cases.