Skip to main content
QUICK REVIEW

[Paper Review] First results of the SUPAX Experiment: Probing Dark Photons

Tim Schneemann, K. Schmieden|arXiv (Cornell University)|Aug 16, 2023
Dark Matter and Cosmic PhenomenaPhysics and Astronomy3 citations
TL;DR

This paper presents the first results from the SUPAX experiment, a cavity-based haloscope operating at 8.3 GHz and liquid helium temperatures, designed to detect dark photons via kinetic mixing with standard model photons. It sets a 95% confidence limit of χ < (6.20 ± 3.15_exp. ± 9.65_SG) × 10⁻¹⁴ for a dark photon mass of 34.34 μeV, demonstrating proof of concept for dark photon detection without magnetic fields.

ABSTRACT

We show the first results of a new cavity based haloscope searching for dark photons with masses around $34~μ ext{eV}$. Dark photons are hypothetical vector particles and a compelling dark matter candidate. Having the same quantum numbers as photons a kinematic mixing between both is expected, leading to conversions from dark photons to standard model photons, where the photon frequency depends on the dark photon mass. For wavelengths in the microwave regime resonators are typically used to enhance the signal. A new experiment is setup at the University of Mainz. In this paper we present the initial results from the new setup searching for dark photons utilising a 8.3 GHz copper cavity at LHe temperatures. Limits on the kinetic mixing parameter $χ&lt; (6.20 \pm 3.15^ ext{(exp.)} \pm 9.65^ ext{(SG)}) \cdot 10^{-14}$ at 95\% CL are set at a single frequency as proof of concept. Finally the next steps of the experiment and expected sensitivity are detailed.

Motivation & Objective

  • To develop and test a cavity-based haloscope for detecting dark photons via kinetic mixing with standard model photons.
  • To demonstrate the feasibility of detecting dark photons without requiring an external magnetic field, unlike axion haloscopes.
  • To establish initial sensitivity limits on the kinetic mixing parameter χ for dark photons with mass ~34.34 μeV.
  • To validate the experimental setup and data analysis pipeline using synthetic signal injections.
  • To lay the groundwork for future upgrades, including superconducting cavity coatings and lower-temperature operation.

Proposed method

  • A high-Q copper microwave cavity tuned to 8.303 GHz is operated at 4.2 K to enhance resonant conversion of dark photons into detectable RF photons.
  • A high electron mobility transistor (HEMT) amplifier is used at cryogenic temperatures to minimize noise in the RF signal readout.
  • The system uses a vector network analyzer (VNA) for S-parameter characterization and a real-time spectrum analyzer (RSA) for signal acquisition at 28 MS/s.
  • Signal analysis employs a Savitzky-Golay (SG) filter to extract narrowband features, with sensitivity calibrated using synthetic dark photon signals.
  • The effective volume V_eff is calculated from the overlap integral between the cavity’s electric field and the dark photon field.
  • The kinetic mixing parameter χ is constrained using the measured RF power and theoretical models of dark photon-to-photon conversion.

Experimental results

Research questions

  • RQ1Can a cavity-based haloscope detect dark photons without requiring an external magnetic field?
  • RQ2What is the sensitivity limit on the kinetic mixing parameter χ for dark photons with mass ~34.34 μeV?
  • RQ3How does the analysis pipeline perform in detecting weak synthetic dark photon signals?
  • RQ4What are the dominant sources of signal attenuation and uncertainty in the current setup?
  • RQ5Can future upgrades such as superconducting coatings and lower temperatures significantly improve sensitivity?

Key findings

  • A 95% confidence upper limit of χ < (6.20 ± 3.15_exp. ± 9.65_SG) × 10⁻¹⁴ is set for a dark photon mass of 34.34 μeV, representing a proof of concept for dark photon detection.
  • The analysis pipeline demonstrated reliable detection of synthetic dark photon signals only when the signal was amplified by a factor of at least five, indicating ~80% signal attenuation in the analysis chain.
  • The experimental uncertainty (exp.) includes cavity characterization and readout noise, while the SG filter uncertainty arises from variations in polynomial fit order and window width.
  • For a fixed-polarization dark photon field, the sensitivity is reduced by a factor of ~6, yielding a limit of χ_pol. < (38 ± 19_exp. ± 58_SG) × 10⁻¹⁴.
  • The current cavity achieves a loaded quality factor Q_L consistent with similar experiments like RADES and CAPP, indicating good performance for the initial setup.
  • Future upgrades, including superconducting cavity coatings and operation at 1.5 K, are expected to increase sensitivity by one order of magnitude.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.