[Paper Review] Full-Stokes polarimetry with circularly polarized feeds - Sources with stable linear and circular polarization in the GHz regime
This paper presents a novel full-Stokes polarimetry pipeline for circularly polarized feeds that corrects instrumental effects—such as linear and circular polarization, and beam-dependent system rotation—before Stokes parameter computation, achieving 0.1–0.2% accuracy in polarization degree and ~1° accuracy in polarization angle. Applied to 150 AGNs over 5.5 years at 4.85 GHz and 8.35 GHz, it identifies five sources with stable linear polarization, 11 with stable circular polarization degree (four with non-zero $m_{\mathrm{c}}$), and eight with stable angle, outperforming the Müller matrix method in low-signal regimes.
We present a pipeline that allows recovering reliable information for all four Stokes parameters with high accuracy. Its novelty relies on the treatment of the instrumental effects already prior to the computation of the Stokes parameters contrary to conventional methods, such as the Müller matrix one. The instrumental linear polarization is corrected across the whole telescope beam and significant Stokes $Q$ and $U$ can be recovered even when the recorded signals are severely corrupted. The accuracy we reach in terms of polarization degree is of the order of 0.1-0.2 %. The polarization angles are determined with an accuracy of almost 1$^{\circ}$. The presented methodology was applied to recover the linear and circular polarization of around 150 Active Galactic Nuclei. The sources were monitored from July 2010 to April 2016 with the Effelsberg 100-m telescope at 4.85 GHz and 8.35 GHz with a cadence of around 1.2 months. The polarized emission of the Moon was used to calibrate the polarization angle. Our analysis showed a small system-induced rotation of about 1$^{\circ}$ at both observing frequencies. Finally, we identify five sources with significant and stable linear polarization; three sources remain constantly linearly unpolarized over the period we examined; a total of 11 sources have stable circular polarization degree $m_\mathrm{c}$ and four of them with non-zero $m_\mathrm{c}$. We also identify eight sources that maintain a stable polarization angle over the examined period. All this is provided to the community for polarization observations reference. We finally show that our analysis method is conceptually different from the traditionally used ones and performs better than the Müller matrix method. Although it was developed for a system equipped with circularly polarized feeds it can easily be modified for systems with linearly polarized feeds as well.
Motivation & Objective
- To develop a high-accuracy polarimetry pipeline that corrects instrumental effects prior to Stokes parameter computation, overcoming limitations of conventional methods like the Müller matrix approach.
- To enable reliable detection of low-level linear and circular polarization (down to 0.3%) in extragalactic radio sources, particularly in the GHz regime.
- To identify and characterize sources with stable linear and circular polarization over long timescales (5.5 years), providing a reference for future observations.
- To calibrate polarization angle using the Moon’s known radial polarization pattern, minimizing system-induced rotation errors.
- To generalize the method for use with both circularly and linearly polarized feeds, enhancing its applicability across radio telescopes.
Proposed method
- Instrumental linear polarization is modeled across the entire telescope beam using unpolarized source responses, enabling correction for both point-like and extended sources.
- The method applies sub-scan-by-sub-scan cleaning of instrumental contributions, ensuring high accuracy even in low-signal regimes.
- Two independent methods—zero-leveling of $m_{\mathrm{c}}$ and singular value decomposition (SVD)—are used to correct instrumental circular polarization with high consistency.
- Opacity and elevation-gain corrections are applied, which are shown to be independent of the incident radiation’s polarization state.
- Instrumental rotation is quantified via Moon observations, revealing a small but measurable offset of 1.26° at 4.85 GHz and -0.5° at 8.35 GHz, with possible elevation dependence.
- The approach avoids reliance on extensive parameter space coverage, unlike the Müller matrix method, and performs better on short observation cycles.
Experimental results
Research questions
- RQ1Can instrumental effects in circularly polarized feeds be corrected effectively before Stokes parameter computation to improve polarization accuracy?
- RQ2What is the minimum detectable polarization degree achievable with this method, particularly for low-flux sources?
- RQ3Which radio sources exhibit long-term stability in linear and circular polarization parameters over a 5.5-year baseline?
- RQ4How does this method compare quantitatively to the Müller matrix method in terms of intra-session stability of Stokes Q and U?
- RQ5Is the instrumental rotation angle stable across different source elevations, and does it require correction for absolute calibration?
Key findings
- The method achieves a polarization degree accuracy of 0.1–0.2% and a polarization angle accuracy of approximately 1°, significantly improving upon conventional approaches.
- Five sources exhibit significant and stable linear polarization over the entire 5.5-year observation period, with three remaining constantly unpolarized.
- A total of 11 sources show stable circular polarization degree ($m_{\mathrm{c}}$), including four with non-zero $m_{\mathrm{c}}$, indicating long-term magnetic field or emission stability.
- Eight sources maintain a stable polarization angle over the observation period, suggesting consistent emission geometry or magnetic field orientation.
- PKS 1127-14 shows stable circular polarization degree and handedness, consistent with measurements from 1984, indicating stability over ~40 years.
- The method outperforms the Müller matrix method by 28% in intra-session stability of Stokes Q and U for low-polarization sources (15–100 mJy), particularly in low-signal regimes.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.