TL;DR

This paper proposes 14 functional requirements—such as AI passport, continuous performance evaluation, and explainable AI—to mitigate patient harm from AI in healthcare. These technical specifications enhance transparency, accountability, and safety, enabling compliance with the EU’s upcoming AI regulatory framework and reducing risks from bias, errors, and misuse.

ABSTRACT

The Directorate General for Parliamentary Research Services of the European Parliament has prepared a report to the Members of the European Parliament where they enumerate seven main risks of Artificial Intelligence (AI) in medicine and healthcare: patient harm due to AI errors, misuse of medical AI tools, bias in AI and the perpetuation of existing inequities, lack of transparency, privacy and security issues, gaps in accountability, and obstacles in implementation. In this study, we propose fourteen functional requirements that AI systems may implement to reduce the risks associated with their medical purpose: AI passport, User management, Regulation check, Academic use only disclaimer, data quality assessment, Clinicians double check, Continuous performance evaluation, Audit trail, Continuous usability test, Review of retrospective/simulated cases, Bias check, eXplainable AI, Encryption and use of field-tested libraries, and Semantic interoperability. Our intention here is to provide specific high-level specifications of technical solutions to ensure continuous good performance and use of AI systems to benefit patients in compliance with the future EU regulatory framework.

Motivation & Objective

  • To address the seven main risks of AI in healthcare identified by the European Parliament Research Service, including patient harm from errors, bias, and lack of transparency.
  • To close gaps in accountability and oversight for AI-based medical tools, especially under current and future EU liability frameworks.
  • To provide high-level, actionable technical specifications that ensure continuous safe performance and ethical use of AI in clinical settings.
  • To support compliance with the EU AI Act and related regulations by embedding risk-mitigation features into AI system design.
  • To enable healthcare professionals to make informed, safe decisions when using AI tools through enhanced transparency and verification mechanisms.

Proposed method

  • Mapped each of the seven identified risks of AI in healthcare to specific functional requirements using a risk-mitigation framework.
  • Proposed 14 functional requirements, including AI passport, user management, regulation check, bias check, and continuous usability testing.
  • Integrated technical components such as audit trails, encryption, field-tested libraries, and semantic interoperability to ensure system integrity.
  • Designed a platform-based approach (e.g., The Aleph platform) to host and manage AI services with built-in compliance features.
  • Incorporated real-time usability feedback via chatbot-based surveys (UEQ and SUS) to monitor user experience continuously.
  • Combined explainable AI (XAI) with clinical double-check mechanisms to validate predictions before use.

Experimental results

Research questions

  • RQ1How can functional requirements be systematically defined to mitigate the risk of patient harm from AI in healthcare?
  • RQ2What technical components are necessary to ensure transparency, accountability, and continuous performance monitoring of medical AI systems?
  • RQ3How can existing regulatory frameworks like the EU AI Act be operationalized through concrete software-level functionalities?
  • RQ4In what ways can AI systems be designed to prevent misuse, bias, and data quality issues in clinical settings?
  • RQ5How can a centralized platform support the deployment of compliant, safe, and auditable AI tools across healthcare institutions?

Key findings

  • The 14 functional requirements collectively address all seven major risks of AI in healthcare identified by the European Parliament, including patient harm from errors and bias.
  • The AI passport enables traceability of model performance, data quality, and training parameters, supporting clinical verification and regulatory compliance.
  • Continuous performance evaluation and audit trails allow for real-time monitoring of AI system behavior and accountability in clinical use.
  • User management with role-based access and 'academic use only' disclaimers reduce the risk of misuse and unauthorized deployment.
  • Integration of explainable AI (XAI) and clinical double-check mechanisms enhances transparency and clinician trust in AI predictions.
  • A platform-based model like The Aleph supports modular, compliant AI deployment with built-in functionalities such as usability testing, regulatory checks, and data encryption.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint